These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A novel method for assessing adherent single-cell stiffness in tension: design and testing of a substrate-based live cell functional imaging device. Bartalena G; Grieder R; Sharma RI; Zambelli T; Muff R; Snedeker JG Biomed Microdevices; 2011 Apr; 13(2):291-301. PubMed ID: 21120698 [TBL] [Abstract][Full Text] [Related]
3. Extreme hardening of PDMS thin films due to high compressive strain and confined thickness. Xu W; Chahine N; Sulchek T Langmuir; 2011 Jul; 27(13):8470-7. PubMed ID: 21634411 [TBL] [Abstract][Full Text] [Related]
4. An Open-Source Membrane Stretcher for Simultaneous Mechanical and Structural Characterizations of Soft Materials and Biological Tissues. Li S; Gee A; Cai N; Bermudez A; Lin NYC bioRxiv; 2024 May; ():. PubMed ID: 38746417 [TBL] [Abstract][Full Text] [Related]
5. Combining atomic force-fluorescence microscopy with a stretching device for analyzing mechanotransduction processes in living cells. Hecht E; Knittel P; Felder E; Dietl P; Mizaikoff B; Kranz C Analyst; 2012 Nov; 137(22):5208-14. PubMed ID: 22977882 [TBL] [Abstract][Full Text] [Related]
6. Intranuclear strain in living cells subjected to substrate stretching: A combined experimental and computational study. Tsukamoto S; Asakawa T; Kimura S; Takesue N; Mofrad MRK; Sakamoto N J Biomech; 2021 Apr; 119():110292. PubMed ID: 33667883 [TBL] [Abstract][Full Text] [Related]
7. A phenomenological approach toward patient-specific computational modeling of articular cartilage including collagen fiber tracking. Pierce DM; Trobin W; Trattnig S; Bischof H; Holzapfel GA J Biomech Eng; 2009 Sep; 131(9):091006. PubMed ID: 19725695 [TBL] [Abstract][Full Text] [Related]
8. A new image processing technique for determination of cell-generated deformations on substrata. Yang Z Comput Methods Biomech Biomed Engin; 2008 Apr; 11(2):159-67. PubMed ID: 18297495 [TBL] [Abstract][Full Text] [Related]
9. Magnetic resonance imaging of mechanical deformations. Koder G; Serša I Magn Reson Imaging; 2016 Feb; 34(2):137-43. PubMed ID: 26523647 [TBL] [Abstract][Full Text] [Related]
10. A robust algorithm for segmenting and tracking clustered cells in time-lapse fluorescent microscopy. Tarnawski W; Kurtcuoglu V; Lorek P; Bodych M; Rotter J; Muszkieta M; Piwowar Ł; Poulikakos D; Majkowski M; Ferrari A IEEE J Biomed Health Inform; 2013 Jul; 17(4):862-9. PubMed ID: 25055315 [TBL] [Abstract][Full Text] [Related]
12. Multiscale stress-strain characterization of onion outer epidermal tissue in wet and dry states. Kim K; Yi H; Zamil MS; Haque MA; Puri VM Am J Bot; 2015 Jan; 102(1):12-20. PubMed ID: 25587144 [TBL] [Abstract][Full Text] [Related]
13. Inverse finite element modeling for characterization of local elastic properties in image-guided failure assessment of human trabecular bone. Zwahlen A; Christen D; Ruffoni D; Schneider P; Schmolz W; Muller R J Biomech Eng; 2015 Jan; 137(1):. PubMed ID: 25367315 [TBL] [Abstract][Full Text] [Related]
14. Estimation of the Deformation Gradient Tensor by Particle Tracking Near a Free Boundary with Quantified Error. Benkley T; Li C; Kolinski J Exp Mech; 2023; 63(7):1255-1270. PubMed ID: 37780097 [TBL] [Abstract][Full Text] [Related]
15. The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques. Defrate LE; van der Ven A; Boyer PJ; Gill TJ; Li G J Biomech; 2006; 39(3):399-405. PubMed ID: 16389080 [TBL] [Abstract][Full Text] [Related]
16. Method for aortic wall strain measurement with three-dimensional ultrasound speckle tracking and fitted finite element analysis. Karatolios K; Wittek A; Nwe TH; Bihari P; Shelke A; Josef D; Schmitz-Rixen T; Geks J; Maisch B; Blase C; Moosdorf R; Vogt S Ann Thorac Surg; 2013 Nov; 96(5):1664-71. PubMed ID: 23998405 [TBL] [Abstract][Full Text] [Related]
17. AFM and Fluorescence Microscopy of Single Cells with Simultaneous Mechanical Stimulation via Electrically Stretchable Substrates. Becerra N; Salis B; Tedesco M; Moreno Flores S; Vena P; Raiteri R Materials (Basel); 2021 Jul; 14(15):. PubMed ID: 34361325 [TBL] [Abstract][Full Text] [Related]
18. Direct mean strain estimation for elastography using nearest-neighbor weighted least-squares approach in the frequency domain. Hasan MK; Anas EM; Alam SK; Lee SY Ultrasound Med Biol; 2012 Oct; 38(10):1759-77. PubMed ID: 22818879 [TBL] [Abstract][Full Text] [Related]
19. Pneumatic Non-Equibiaxial Cell Stretching Device With Live-Cell Imaging. Wang J; Chatterjee A; Zigan C; Alborn M; Chan DD; Chortos A IEEE Trans Biomed Eng; 2024 Mar; 71(3):820-830. PubMed ID: 37747858 [TBL] [Abstract][Full Text] [Related]
20. A polymeric cell stretching device for real-time imaging with optical microscopy. Huang Y; Nguyen NT Biomed Microdevices; 2013 Dec; 15(6):1043-54. PubMed ID: 23868118 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]