These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 26932085)

  • 41. Final design of thermal diagnostic system in SPIDER ion source.
    Brombin M; Dalla Palma M; Pasqualotto R; Pomaro N
    Rev Sci Instrum; 2016 Nov; 87(11):11D433. PubMed ID: 27910628
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Design of a cavity ring-down spectroscopy diagnostic for negative ion rf source SPIDER.
    Pasqualotto R; Alfier A; Lotto L
    Rev Sci Instrum; 2010 Oct; 81(10):10D710. PubMed ID: 21033903
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Overview of diagnostics on a small-scale RF source for fusion (ROBIN) and the one planned for the diagnostic beam for ITER.
    Bandyopadhyay M; Singh MJ; Pandya K; Bhuyan M; Tyagi H; Bharathi P; Shah S; Chakraborty AK
    Rev Sci Instrum; 2022 Feb; 93(2):023504. PubMed ID: 35232154
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Study on space charge compensation in negative hydrogen ion beam.
    Zhang AL; Peng SX; Ren HT; Zhang T; Zhang JF; Xu Y; Guo ZY; Chen JE
    Rev Sci Instrum; 2016 Feb; 87(2):02B915. PubMed ID: 26932087
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Overview of the negative ion based neutral beam injectors for ITER.
    Schunke B; Boilson D; Chareyre J; Choi CH; Decamps H; El-Ouazzani A; Geli F; Graceffa J; Hemsworth R; Kushwah M; Roux K; Shah D; Singh M; Svensson L; Urbani M
    Rev Sci Instrum; 2016 Feb; 87(2):02C101. PubMed ID: 26932111
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Preliminary design of electrostatic sensors for MITICA beam line components.
    Spagnolo S; Spolaore M; Dalla Palma M; Pasqualotto R; Sartori E; Serianni G; Veltri P
    Rev Sci Instrum; 2016 Feb; 87(2):02B931. PubMed ID: 26932103
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Formation of large negative deuterium ion beams at ELISE.
    Wünderlich D; Riedl R; Mario I; Mimo A; Fantz U; Heinemann B; Kraus W
    Rev Sci Instrum; 2019 Nov; 90(11):113304. PubMed ID: 31779429
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Overview of ion source characterization diagnostics in INTF.
    Bandyopadhyay M; Sudhir D; Bhuyan M; Soni J; Tyagi H; Joshi J; Yadav A; Rotti C; Parmar D; Patel H; Pillai S; Chakraborty A
    Rev Sci Instrum; 2016 Feb; 87(2):02B906. PubMed ID: 26932078
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Design of infrared radiation diagnostic calorimeter for the prototype radio frequency driven negative ion source for neutral beam injection.
    Xu Y; Xie Y; Jiang C; Wei J; Li J; Gu Y; Yu L; Liang L; Zhao Y; Tao L; Xie Y; Hu C
    Rev Sci Instrum; 2020 Apr; 91(4):043501. PubMed ID: 32357727
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Dependence of beam emittance on plasma electrode temperature and rf-power, and filter-field tuning with center-gapped rod-filter magnets in J-PARC rf-driven H(-) ion source.
    Ueno A; Koizumi I; Ohkoshi K; Ikegami K; Takagi A; Yamazaki S; Oguri H
    Rev Sci Instrum; 2014 Feb; 85(2):02B133. PubMed ID: 24593573
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Modeling and simulation of a beam emission spectroscopy diagnostic for the ITER prototype neutral beam injector.
    Barbisan M; Zaniol B; Pasqualotto R
    Rev Sci Instrum; 2014 Nov; 85(11):11E430. PubMed ID: 25430337
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Physics design of the injector source for ITER neutral beam injector (invited).
    Antoni V; Agostinetti P; Aprile D; Cavenago M; Chitarin G; Fonnesu N; Marconato N; Pilan N; Sartori E; Serianni G; Veltri P
    Rev Sci Instrum; 2014 Feb; 85(2):02B128. PubMed ID: 24593568
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparative study of beam losses and heat loads reduction methods in MITICA beam source.
    Sartori E; Agostinetti P; Dal Bello S; Marcuzzi D; Serianni G; Sonato P; Veltri P
    Rev Sci Instrum; 2014 Feb; 85(2):02B308. PubMed ID: 24593585
    [TBL] [Abstract][Full Text] [Related]  

  • 54. 3D numerical simulations of negative hydrogen ion extraction using realistic plasma parameters, geometry of the extraction aperture and full 3D magnetic field map.
    Mochalskyy S; Wünderlich D; Ruf B; Franzen P; Fantz U; Minea T
    Rev Sci Instrum; 2014 Feb; 85(2):02B301. PubMed ID: 24593578
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Multiple delivery cesium oven system for negative ion sources.
    Bansal G; Bhartiya S; Pandya K; Bandyopadhyay M; Singh MJ; Soni J; Gahlaut A; Parmar KG; Chakraborty A
    Rev Sci Instrum; 2012 Feb; 83(2):02B118. PubMed ID: 22380275
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Development of a high-brightness and low-divergence lithium neutral beam for a Zeeman polarimetry on JT-60U.
    Kojima A; Kamiya K; Iguchi H; Fujita T; Kakiuchi H; Kamada Y
    Rev Sci Instrum; 2008 Sep; 79(9):093502. PubMed ID: 19044408
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Compact electron beam ion sources/traps: review and prospects.
    Zschornack G; Kreller M; Ovsyannikov VP; Grossman F; Kentsch U; Schmidt M; Ullmann F; Heller R
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02A703. PubMed ID: 18315151
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Final design of the beam source for the MITICA injector.
    Marcuzzi D; Agostinetti P; Dalla Palma M; De Muri M; Chitarin G; Gambetta G; Marconato N; Pasqualotto R; Pavei M; Pilan N; Rizzolo A; Serianni G; Toigo V; Trevisan L; Visentin M; Zaccaria P; Zaupa M; Boilson D; Graceffa J; Hemsworth RS; Choi CH; Marti M; Roux K; Singh MJ; Masiello A; Froeschle M; Heinemann B; Nocentini R; Riedl R; Tobari H; de Esch HP; Muvvala VN
    Rev Sci Instrum; 2016 Feb; 87(2):02B309. PubMed ID: 26932037
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Model for the description of ion beam extraction from electron cyclotron resonance ion sources.
    Spädtke P
    Rev Sci Instrum; 2010 Feb; 81(2):02B725. PubMed ID: 20192465
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Visible cameras as a non-invasive diagnostic to study negative ion beam properties.
    Ugoletti M; Agostini M; Barbisan M; Brombin M; Cavenago M; Delogu RS; Molon F; Pasqualotto R; Pimazzoni A; Serianni G
    Rev Sci Instrum; 2021 Apr; 92(4):043302. PubMed ID: 34243389
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.