BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

442 related articles for article (PubMed ID: 26932349)

  • 21. Effects of cardiac output levels on the measurement of transpulmonary thermodilution cardiac output in patients with acute respiratory distress syndrome.
    Huang CC; Chen NH; Li LF; Yang CT; Hsiao HF; Chen YH; Lin HL; Kao KC
    J Trauma Acute Care Surg; 2012 Nov; 73(5):1236-41. PubMed ID: 22914086
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values.
    Asamoto M; Orii R; Otsuji M; Bougaki M; Imai Y; Yamada Y
    J Clin Monit Comput; 2017 Aug; 31(4):709-716. PubMed ID: 27300325
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Systematic error of cardiac output measured by bolus thermodilution with a pulmonary artery catheter compared with that measured by an aortic flow probe in a pig model.
    Yang XX; Critchley LA; Rowlands DK; Fang Z; Huang L
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1133-9. PubMed ID: 24035141
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination.
    Zöllner C; Goetz AE; Weis M; Mörstedt K; Pichler B; Lamm P; Kilger E; Haller M
    Can J Anaesth; 2001 Dec; 48(11):1143-7. PubMed ID: 11744592
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis.
    Zhang Y; Wang Y; Shi J; Hua Z; Xu J
    PLoS One; 2019; 14(10):e0222105. PubMed ID: 31581196
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effects of extravascular lung water on the measurement of transpulmonary thermodilution cardiac output in acute respiratory distress syndrome patients.
    Huang CC; Kao KC; Fu JY; Hsieh MJ
    J Cardiothorac Vasc Anesth; 2011 Jun; 25(3):481-5. PubMed ID: 20829067
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre.
    Cho YJ; Koo CH; Kim TK; Hong DM; Jeon Y
    J Clin Monit Comput; 2016 Dec; 30(6):771-782. PubMed ID: 26429135
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Automated echocardiography for measuring and tracking cardiac output after cardiac surgery: a validation study.
    Juhl-Olsen P; Smith SH; Grejs AM; Jørgensen MRS; Bhavsar R; Vistisen ST
    J Clin Monit Comput; 2020 Oct; 34(5):913-922. PubMed ID: 31677135
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Agreement in hemodynamic monitoring during orthotopic liver transplantation: a comparison of FloTrac/Vigileo at two monitoring sites with pulmonary artery catheter thermodilution.
    Lee M; Weinberg L; Pearce B; Scurrah N; Story DA; Pillai P; McCall PR; P McNicol L; Peyton PJ
    J Clin Monit Comput; 2017 Apr; 31(2):343-351. PubMed ID: 26884378
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of norepinephrine dosage and calibration frequency on accuracy of pulse contour-derived cardiac output.
    Gruenewald M; Meybohm P; Renner J; Broch O; Caliebe A; Weiler N; Steinfath M; Scholz J; Bein B
    Crit Care; 2011; 15(1):R22. PubMed ID: 21241481
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes.
    Suehiro K; Tanaka K; Mikawa M; Uchihara Y; Matsuyama T; Matsuura T; Funao T; Yamada T; Mori T; Nishikawa K
    J Cardiothorac Vasc Anesth; 2015; 29(3):656-62. PubMed ID: 25440654
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting.
    Smetkin AA; Hussain A; Kuzkov VV; Bjertnæs LJ; Kirov MY
    Br J Anaesth; 2014 Jun; 112(6):1024-31. PubMed ID: 24531685
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cardiac output measurement in liver transplantation patients using pulmonary and transpulmonary thermodilution: a comparative study.
    Vetrugno L; Bignami E; Barbariol F; Langiano N; De Lorenzo F; Matellon C; Menegoz G; Della Rocca G
    J Clin Monit Comput; 2019 Apr; 33(2):223-231. PubMed ID: 29725794
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bioreactance Is Not Interchangeable with Thermodilution for Measuring Cardiac Output during Adult Liver Transplantation.
    Han S; Lee JH; Kim G; Ko JS; Choi SJ; Kwon JH; Heo BY; Gwak MS
    PLoS One; 2015; 10(5):e0127981. PubMed ID: 26017364
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A comparison of three minimally invasive cardiac output devices with thermodilution in elective cardiac surgery.
    Phan TD; Kluger R; Wan C; Wong D; Padayachee A
    Anaesth Intensive Care; 2011 Nov; 39(6):1014-21. PubMed ID: 22165352
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Comparison of cardiac output measurement in critical patients using transesophageal Doppler or thermodilution: a preliminary report].
    Andresen M; Henríquez M; Mercado M; Farías G; Castillo C; Benítez C; Dougnac A
    Rev Med Chil; 2005 Jul; 133(7):761-6. PubMed ID: 16341381
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Comparison between continuous and intermittent thermodilution measurement of cardiac output during coronary artery bypass operation].
    Schulz K; Abel HH; Werning P
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Apr; 32(4):226-33. PubMed ID: 9289022
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of Continuous Cardiac Output Measurement With the LiDCOplus System During Intra-Aortic Counterpulsation After Cardiac Surgery.
    Menger J; Mora B; Skhirtladze K; Fischer A; Jan Ankersmit H; Dworschak M
    J Cardiothorac Vasc Anesth; 2016 Jun; 30(3):592-8. PubMed ID: 26718662
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pulse wave transit time measurements of cardiac output in patients undergoing partial hepatectomy: a comparison of the esCCO system with thermodilution.
    Tsutsui M; Araki Y; Masui K; Kazama T; Sugo Y; Archer TL; Manecke GR
    Anesth Analg; 2013 Dec; 117(6):1307-12. PubMed ID: 24257379
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure.
    Albert NM; Hail MD; Li J; Young JB
    Am J Crit Care; 2004 Nov; 13(6):469-79. PubMed ID: 15568652
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 23.