These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

299 related articles for article (PubMed ID: 2693426)

  • 1. Membrane filtration differentiation of E. coli from coliforms in the examination of water.
    Mates A; Shaffer M
    J Appl Bacteriol; 1989 Sep; 67(3):343-6. PubMed ID: 2693426
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of fluorogenic and conventional membrane filter media for enumerating coliform bacteria.
    Cenci G; De Bartolomeo A; Caldini G
    Microbios; 1993; 76(306):47-54. PubMed ID: 8264433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of Escherichia coli by the nutrient agar plus 4-methylumbelliferyl beta-D-glucuronide (MUG) membrane filter method.
    Shadix LC; Dunnigan ME; Rice EW
    Can J Microbiol; 1993 Nov; 39(11):1066-70. PubMed ID: 8306208
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the recoveries of Escherichia coli and total coliforms from drinking water by the MI agar method and the U.S. Environmental Protection Agency-approved membrane filter method.
    Brenner KP; Rankin CC; Sivaganesan M; Scarpino PV
    Appl Environ Microbiol; 1996 Jan; 62(1):203-8. PubMed ID: 8572697
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New medium for the simultaneous detection of total coliforms and Escherichia coli in water.
    Brenner KP; Rankin CC; Roybal YR; Stelma GN; Scarpino PV; Dufour AP
    Appl Environ Microbiol; 1993 Nov; 59(11):3534-44. PubMed ID: 8285660
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection and enumeration of coliforms in drinking water: current methods and emerging approaches.
    Rompré A; Servais P; Baudart J; de-Roubin MR; Laurent P
    J Microbiol Methods; 2002 Mar; 49(1):31-54. PubMed ID: 11777581
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of media for simultaneous enumeration of total coliform and Escherichia coli in drinking water supplies by membrane filtration techniques.
    Wang D; Fiessel W
    J Environ Sci (China); 2008; 20(3):273-7. PubMed ID: 18595392
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of bottled water for Escherichia coli and total coliforms.
    Grant MA
    J Food Prot; 1998 Mar; 61(3):334-8. PubMed ID: 9708306
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new membrane filtration medium for simultaneous detection and enumeration of Escherichia coli and total coliforms.
    Grant MA
    Appl Environ Microbiol; 1997 Sep; 63(9):3526-30. PubMed ID: 9293003
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid detection of fluorescent and chemiluminescent total coliforms and Escherichia coli on membrane filters.
    Van Poucke SO; Nelis HJ
    J Microbiol Methods; 2000 Nov; 42(3):233-44. PubMed ID: 11044567
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New medium for improved recovery of coliform bacteria from drinking water.
    LeChevallier MW; Cameron SC; McFeters GA
    Appl Environ Microbiol; 1983 Feb; 45(2):484-92. PubMed ID: 6338827
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative determination of total coliforms and Escherichia coli in marine waters with chromogenic and fluorogenic media.
    Geissler K; Manafi M; Amorós I; Alonso JL
    J Appl Microbiol; 2000 Feb; 88(2):280-5. PubMed ID: 10735996
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the lactose Tergitol-7, m-Endo LES, Colilert 18, Readycult Coliforms 100, Water-Check-100, 3M Petrifilm EC and DryCult Coliform test methods for detection of total coliforms and Escherichia coli in water samples.
    Hörman A; Hänninen ML
    Water Res; 2006 Oct; 40(17):3249-56. PubMed ID: 16916531
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of two media and different plating techniques for enumeration of thermotolerant coliforms in river water.
    Tamagnini LM; González RD
    Rev Latinoam Microbiol; 2001; 43(2):84-7. PubMed ID: 17061492
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A simple and cost-effective method for the quantification of total coliforms and Escherichia coli in potable water.
    Yáñez MA; Valor C; Catalán V
    J Microbiol Methods; 2006 Jun; 65(3):608-11. PubMed ID: 16202463
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance validation of chromogenic coliform agar for the enumeration of Escherichia coli and coliform bacteria.
    Lange B; Strathmann M; Oßmer R
    Lett Appl Microbiol; 2013 Dec; 57(6):547-53. PubMed ID: 23952651
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative performance of Colisure.
    McFeters GA; Broadaway SC; Pyle BH; Pickett M; Egozy Y
    J Am Water Works Assoc; 1997 Sep; 89(9):112-20. PubMed ID: 11540632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Membrane filter procedure for enumerating the component genera of the coliform group in seawater.
    Dufour AP; Cabelli VJ
    Appl Microbiol; 1975 Jun; 29(6):826-33. PubMed ID: 1098575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Enumeration of heterotrophs, fecal coliforms and Escherichia coli in water: comparison of 3M Petrifilm plates with standard plating procedures.
    Schraft H; Watterworth LA
    J Microbiol Methods; 2005 Mar; 60(3):335-42. PubMed ID: 15649535
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative determination of Escherichia coli from faecal coliforms in seawater.
    Mates A; Schaffer M
    Microbios; 1988; 53(216-217):161-5. PubMed ID: 3292874
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.