168 related articles for article (PubMed ID: 26936722)
1. Phase aberration simulation study of MRgFUS breast treatments.
Farrer AI; Almquist S; Dillon CR; Neumayer LA; Parker DL; Christensen DA; Payne A
Med Phys; 2016 Mar; 43(3):1374-84. PubMed ID: 26936722
[TBL] [Abstract][Full Text] [Related]
2. Experimental assessment of phase aberration correction for breast MRgFUS therapy.
Dillon CR; Farrer A; McLean H; Almquist S; Christensen D; Payne A
Int J Hyperthermia; 2018 Sep; 34(6):731-743. PubMed ID: 29278946
[TBL] [Abstract][Full Text] [Related]
3. Comparison of computer simulations and clinical treatment results of magnetic resonance-guided focused ultrasound surgery (MRgFUS) of uterine fibroids.
Hyvärinen M; Huang Y; David E; Hynynen K
Med Phys; 2022 Apr; 49(4):2101-2119. PubMed ID: 34601729
[TBL] [Abstract][Full Text] [Related]
4. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria.
Miller GW; Eames M; Snell J; Aubry JF
Med Phys; 2015 May; 42(5):2223-33. PubMed ID: 25979016
[TBL] [Abstract][Full Text] [Related]
5. Transcranial phase aberration correction using beam simulations and MR-ARFI.
Vyas U; Kaye E; Pauly KB
Med Phys; 2014 Mar; 41(3):032901. PubMed ID: 24593740
[TBL] [Abstract][Full Text] [Related]
6. Application of Zernike polynomials towards accelerated adaptive focusing of transcranial high intensity focused ultrasound.
Kaye EA; Hertzberg Y; Marx M; Werner B; Navon G; Levoy M; Pauly KB
Med Phys; 2012 Oct; 39(10):6254-63. PubMed ID: 23039661
[TBL] [Abstract][Full Text] [Related]
7. Influence of cerebrospinal fluid on power absorption during transcranial magnetic resonance-guided focused ultrasound treatment.
Slominski E; Marchant J; Judd W; Alexander MD; Rolston JD; Odéen H; Rieke V; Christensen DA; Parker DL
Med Phys; 2023 Jun; 50(6):3245-3257. PubMed ID: 37078516
[TBL] [Abstract][Full Text] [Related]
8. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
Ramaekers P; Ries M; Moonen CT; de Greef M
Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731
[TBL] [Abstract][Full Text] [Related]
9. Simulating thermal effects of MR-guided focused ultrasound in cortical bone and its surrounding tissue.
Hudson TJ; Looi T; Pichardo S; Amaral J; Temple M; Drake JM; Waspe AC
Med Phys; 2018 Feb; 45(2):506-519. PubMed ID: 29193144
[TBL] [Abstract][Full Text] [Related]
10. High intensity focused ultrasound with large aperture transducers: a MRI based focal point correction for tissue heterogeneity.
Mougenot C; Tillander M; Koskela J; Köhler MO; Moonen C; Ries M
Med Phys; 2012 Apr; 39(4):1936-45. PubMed ID: 22482615
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound focusing using magnetic resonance acoustic radiation force imaging: application to ultrasound transcranial therapy.
Hertzberg Y; Volovick A; Zur Y; Medan Y; Vitek S; Navon G
Med Phys; 2010 Jun; 37(6):2934-42. PubMed ID: 20632605
[TBL] [Abstract][Full Text] [Related]
12. Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks.
de Greef M; Schubert G; Wijlemans JW; Koskela J; Bartels LW; Moonen CT; Ries M
Med Phys; 2015 Aug; 42(8):4685-97. PubMed ID: 26233196
[TBL] [Abstract][Full Text] [Related]
13. MR-guided adaptive focusing of therapeutic ultrasound beams in the human head.
Marsac L; Chauvet D; Larrat B; Pernot M; Robert B; Fink M; Boch AL; Aubry JF; Tanter M
Med Phys; 2012 Feb; 39(2):1141-9. PubMed ID: 22320825
[TBL] [Abstract][Full Text] [Related]
14. Improving thermal dose accuracy in magnetic resonance-guided focused ultrasound surgery: Long-term thermometry using a prior baseline as a reference.
Bitton RR; Webb TD; Pauly KB; Ghanouni P
J Magn Reson Imaging; 2016 Jan; 43(1):181-9. PubMed ID: 26119129
[TBL] [Abstract][Full Text] [Related]
15. Simulation study of the effects of near- and far-field heating during focused ultrasound uterine fibroid ablation using an electronically focused phased array: A theoretical analysis of patient safety.
Ellens N; Hynynen K
Med Phys; 2014 Jul; 41(7):072902. PubMed ID: 24989412
[TBL] [Abstract][Full Text] [Related]
16. The effect of electronically steering a phased array ultrasound transducer on near-field tissue heating.
Payne A; Vyas U; Todd N; de Bever J; Christensen DA; Parker DL
Med Phys; 2011 Sep; 38(9):4971-81. PubMed ID: 21978041
[TBL] [Abstract][Full Text] [Related]
17. Laser interstitial thermotherapy of small breast fibroadenomas: numerical simulations.
Marqa MF; Mordon S; Betrouni N
Lasers Surg Med; 2012 Dec; 44(10):832-9. PubMed ID: 23184405
[TBL] [Abstract][Full Text] [Related]
18. Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array.
Payne A; Merrill R; Minalga E; Vyas U; de Bever J; Todd N; Hadley R; Dumont E; Neumayer L; Christensen D; Roemer R; Parker D
Med Phys; 2012 Mar; 39(3):1552-60. PubMed ID: 22380387
[TBL] [Abstract][Full Text] [Related]
19. Intracranial inertial cavitation threshold and thermal ablation lesion creation using MRI-guided 220-kHz focused ultrasound surgery: preclinical investigation.
Xu Z; Carlson C; Snell J; Eames M; Hananel A; Lopes MB; Raghavan P; Lee CC; Yen CP; Schlesinger D; Kassell NF; Aubry JF; Sheehan J
J Neurosurg; 2015 Jan; 122(1):152-61. PubMed ID: 25380106
[TBL] [Abstract][Full Text] [Related]
20. Magnetic resonance-guided focused ultrasound treatment of extra-abdominal desmoid tumors: a retrospective multicenter study.
Ghanouni P; Dobrotwir A; Bazzocchi A; Bucknor M; Bitton R; Rosenberg J; Telischak K; Busacca M; Ferrari S; Albisinni U; Walters S; Gold G; Ganjoo K; Napoli A; Pauly KB; Avedian R
Eur Radiol; 2017 Feb; 27(2):732-740. PubMed ID: 27147222
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]