297 related articles for article (PubMed ID: 26938712)
1. Comparison of Osteotome and Conventional Drilling Techniques for Primary Implant Stability: An In Vitro Study.
Tsolaki IN; Tonsekar PP; Najafi B; Drew HJ; Sullivan AJ; Petrov SD
J Oral Implantol; 2016 Aug; 42(4):321-5. PubMed ID: 26938712
[TBL] [Abstract][Full Text] [Related]
2. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study.
Ahn SJ; Leesungbok R; Lee SW; Heo YK; Kang KL
J Prosthet Dent; 2012 Jun; 107(6):366-72. PubMed ID: 22633592
[TBL] [Abstract][Full Text] [Related]
3. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets.
Cehreli MC; Kökat AM; Comert A; Akkocaoğlu M; Tekdemir I; Akça K
Clin Oral Implants Res; 2009 Oct; 20(10):1163-9. PubMed ID: 19681964
[TBL] [Abstract][Full Text] [Related]
4. A comparative study of crestal bone loss and implant stability between osteotome and conventional implant insertion techniques: a randomized controlled clinical trial study.
Shayesteh YS; Khojasteh A; Siadat H; Monzavi A; Bassir SH; Hossaini M; Alikhasi M
Clin Implant Dent Relat Res; 2013 Jun; 15(3):350-7. PubMed ID: 21815994
[TBL] [Abstract][Full Text] [Related]
5. Resonance frequency analysis (RFA) and insertional torque (IT) stability comparisons of implants placed using osteotomes versus drilling techniques: A preliminary case study.
Xing Y; Khandelwal N; Petrov S; Drew HJ; Mupparapu M
Quintessence Int; 2015 Oct; 46(9):789-98. PubMed ID: 26159207
[TBL] [Abstract][Full Text] [Related]
6. Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis.
Farronato D; Manfredini M; Stocchero M; Caccia M; Azzi L; Farronato M
J Oral Implantol; 2020 Jun; 46(3):182-189. PubMed ID: 32582919
[TBL] [Abstract][Full Text] [Related]
7. Osteotome versus conventional drilling technique for implant site preparation: a comparative study in the rabbit.
Nóbrega AR; Norton A; Silva JA; Silva JP; Branco FM; Anitua E
Int J Periodontics Restorative Dent; 2012 Jun; 32(3):e109-15. PubMed ID: 22408780
[TBL] [Abstract][Full Text] [Related]
8. Implant Stability Quotients of Osteotome Bone Expansion and Conventional Drilling Technique for 4.1 mm Diameter Implant at Posterior Mandible.
Hong HH; Hong A; Yang LY; Chang WY; Huang YF; Lin YT
Clin Implant Dent Relat Res; 2017 Apr; 19(2):253-260. PubMed ID: 27665748
[TBL] [Abstract][Full Text] [Related]
9. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implants.
Degidi M; Daprile G; Piattelli A
Clin Implant Dent Relat Res; 2012 Aug; 14(4):501-7. PubMed ID: 20849539
[TBL] [Abstract][Full Text] [Related]
10. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data.
Turkyilmaz I; Aksoy U; McGlumphy EA
Clin Implant Dent Relat Res; 2008 Dec; 10(4):231-7. PubMed ID: 18384409
[TBL] [Abstract][Full Text] [Related]
11. Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.
Sagheb K; Kumar VV; Azaripour A; Walter C; Al-Nawas B; Kämmerer PW
Clin Oral Implants Res; 2017 Feb; 28(2):207-213. PubMed ID: 26799448
[TBL] [Abstract][Full Text] [Related]
12. Comparison of crestal bone loss and implant stability among the implants placed with conventional procedure and using osteotome technique: a clinical study.
Padmanabhan TV; Gupta RK
J Oral Implantol; 2010; 36(6):475-83. PubMed ID: 21142790
[TBL] [Abstract][Full Text] [Related]
13. Influence of Stepped Osteotomy on Primary Stability of Implants Inserted in Low-Density Bone Sites: An In Vitro Study.
Degidi M; Daprile G; Piattelli A
Int J Oral Maxillofac Implants; 2017; 32(1):37-41. PubMed ID: 28095514
[TBL] [Abstract][Full Text] [Related]
14. Two different implant designs and impact of related drilling protocols on primary stability in different bone densities: an in vitro comparison study.
Sennerby L; Pagliani L; Petersson A; Verrocchi D; Volpe S; Andersson P
Int J Oral Maxillofac Implants; 2015; 30(3):564-8. PubMed ID: 26009906
[TBL] [Abstract][Full Text] [Related]
15. Primary Stability of Short Implants Inserted Using Piezoelectric or Drilling Systems: An In Vitro Comparison.
Stacchi C; De Biasi M; Torelli L; Robiony M; Di Lenarda R; Angerame D
J Oral Implantol; 2019 Aug; 45(4):259-266. PubMed ID: 31532728
[TBL] [Abstract][Full Text] [Related]
16. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study.
Fuster-Torres MÁ; Peñarrocha-Diago M; Peñarrocha-Oltra D; Peñarrocha-Diago M
Int J Oral Maxillofac Implants; 2011; 26(5):1051-6. PubMed ID: 22010089
[TBL] [Abstract][Full Text] [Related]
17. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis.
Falco A; Berardini M; Trisi P
Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study.
Marković A; Calvo-Guirado JL; Lazić Z; Gómez-Moreno G; Ćalasan D; Guardia J; Čolic S; Aguilar-Salvatierra A; Gačić B; Delgado-Ruiz R; Janjić B; Mišić T
Clin Implant Dent Relat Res; 2013 Jun; 15(3):341-9. PubMed ID: 22171668
[TBL] [Abstract][Full Text] [Related]
19. Developing Stability of Posterior Mandibular Implants Placed With Osteotome Expansion Technique Compared With Conventional Drilling Techniques.
Lin YT; Hong A; Peng YC; Hong HH
J Oral Implantol; 2017 Apr; 43(2):131-138. PubMed ID: 28048965
[TBL] [Abstract][Full Text] [Related]
20. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone.
Bilhan H; Geckili O; Mumcu E; Bozdag E; Sünbüloğlu E; Kutay O
J Oral Rehabil; 2010 Dec; 37(12):900-7. PubMed ID: 20529176
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]