  • 21. [Troubleshooting in Patients with Implanted Pacemaker and ICD].
    Meyer Zu Vilsendorf D; Hansky B; Baumann P; Stellbrink C
    Dtsch Med Wochenschr; 2018 Nov; 143(22):1608-1616. PubMed ID: 30376684
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Initiation of ventricular tachycardia by interruption of pacemaker-mediated tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator.
    Van Gelder BM; Meijer A; Dekker LR; Bracke FA
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1227-30. PubMed ID: 19719503
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pacemaker contact dermatitis: The effective use of a polytetrafluoroethylene sheet.
    Ishii K; Kodani E; Miyamoto S; Otsuka T; Hosone M; Ogata K; Sato W; Matsumoto S; Tadera T; Ibuki C; Kusama Y; Atarashi H
    Pacing Clin Electrophysiol; 2006 Nov; 29(11):1299-302. PubMed ID: 17100687
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Inappropriate shock delivery and biventricular pacing cardiac defibrillators.
    Liu BC; Villareal RP; Hariharan R; Rasekh A; Massumi A
    Tex Heart Inst J; 2003; 30(1):45-9. PubMed ID: 12638671
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pacemaker contact sensitivity: case report and review of the literature.
    Déry JP; Gilbert M; O'Hara G; Champagne J; Desaulniers D; Cartier P; Philippon F
    Pacing Clin Electrophysiol; 2002 May; 25(5):863-5. PubMed ID: 12049383
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.
    Rapsang AG; Bhattacharyya P
    Braz J Anesthesiol; 2014; 64(3):205-14. PubMed ID: 24907883
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Intradermal test in contact allergy to metals.
    Meneghini C; Angelini G
    Acta Derm Venereol Suppl (Stockh); 1979; 59(85):123-4. PubMed ID: 294087
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Contact dermatitis in hospital patients.
    Ancona A; Arévalo A; Macotela E
    Dermatol Clin; 1990 Jan; 8(1):95-105. PubMed ID: 2406065
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Care of the pacemaker/implantable cardioverter defibrillator patient in the ED.
    McMullan J; Valento M; Attari M; Venkat A
    Am J Emerg Med; 2007 Sep; 25(7):812-22. PubMed ID: 17870488
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Outcomes in pacemaker-dependent patients upgraded from conventional pacemakers to cardiac resynchronization therapy-defibrillators.
    Adelstein E; Schwartzman D; Bazaz R; Jain S; Gorcsan J; Saba S
    Heart Rhythm; 2014 Jun; 11(6):1008-14. PubMed ID: 24657426
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Patch testing with a large series of metal allergens: findings from more than 1,000 patients in one decade at Mayo Clinic.
    Davis MD; Wang MZ; Yiannias JA; Keeling JH; Connolly SM; Richardson DM; Farmer SA
    Dermatitis; 2011; 22(5):256-71. PubMed ID: 22652903
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Case report: Perioperative pacemaker-mediated tachycardia in the patient with a dual chamber implantable cardioverter-defibrillator.
    Izrailtyan I; Schiller RJ; Katz RI; Almasry IO
    Anesth Analg; 2013 Feb; 116(2):307-10. PubMed ID: 23266999
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effect of hyperkalaemia on cardiac rhythm devices.
    Barold SS; Herweg B
    Europace; 2014 Apr; 16(4):467-76. PubMed ID: 24465006
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Allergic reactions to implant materials].
    Thomas P
    Orthopade; 2003 Jan; 32(1):60-4. PubMed ID: 12557087
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Patch testing with perfume mixture.
    Veien NK; Hattel T; Justesen O; Nørholm A
    Acta Derm Venereol; 1982; 62(4):341-3. PubMed ID: 6183871
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hypersensitivity to material and environmental burden as a possible cause of late complications of cardiac implantable electronic devices.
    Manoušek J; Andršová I; Stejskal V; Vlašínová J; Sepši M; Kuta J; Klánová J; Mazík M; Jarkovský J; Šnajdrová L; Benešová K; Novotný T; Zadáková A; Špinar J
    Europace; 2018 Sep; 20(9):e140-e147. PubMed ID: 29016950
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Cardiac pacemaker and internal defibrillators (ICD). Basic principles and new important developments, status 1998].
    Deisenhofer I; Karch M; Zrenner B; Schmitt C; Schömig A
    Fortschr Med; 1998 Aug; 116(22-23):20-4, 26. PubMed ID: 9773595
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Interferences in the everyday life of the patient with a cardiac pacemaker or an implantable defibrillator].
    Sadoul N; Blangy H; Dodinot B
    Arch Mal Coeur Vaiss; 2003 Apr; 96 Spec No 3():12-21. PubMed ID: 12741327
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Permanent pacemaker and implantable cardioverter defibrillator infection: a population-based study.
    Uslan DZ; Sohail MR; St Sauver JL; Friedman PA; Hayes DL; Stoner SM; Wilson WR; Steckelberg JM; Baddour LM
    Arch Intern Med; 2007 Apr; 167(7):669-75. PubMed ID: 17420425
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pacemaker dermatitis.
    Romaguera C; Grimalt F
    Contact Dermatitis; 1981 Nov; 7(6):333. PubMed ID: 7338034
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]