127 related articles for article (PubMed ID: 26949758)
1. Performance of High-Flow-Rate Samplers for Respirable Crystalline Silica Measurement Under Field Conditions: Preliminary Study.
Coggins MA; Healy CB; Lee T; Harper M
Silica Assoc Respirable Miner Part (2012); 2014 Jan; STP 1565():125-138. PubMed ID: 26949758
[TBL] [Abstract][Full Text] [Related]
2. Silica Measurement with High Flow Rate Respirable Size Selective Samplers: A Field Study.
Lee T; Harper M; Kashon M; Lee LA; Healy CB; Coggins MA; Susi P; O'Brien A
Ann Occup Hyg; 2016 Apr; 60(3):334-47. PubMed ID: 26608952
[TBL] [Abstract][Full Text] [Related]
3. Collection efficiencies of high flow rate personal respirable samplers when measuring Arizona road dust and analysis of quartz by x-ray diffraction.
Stacey P; Lee T; Thorpe A; Roberts P; Frost G; Harper M
Ann Occup Hyg; 2014 May; 58(4):512-23. PubMed ID: 24470535
[TBL] [Abstract][Full Text] [Related]
4. Performance of high flow rate samplers for respirable particle collection.
Lee T; Kim SW; Chisholm WP; Slaven J; Harper M
Ann Occup Hyg; 2010 Aug; 54(6):697-709. PubMed ID: 20660144
[TBL] [Abstract][Full Text] [Related]
5. Quartz measurement in coal dust with high-flow rate samplers: laboratory study.
Lee T; Lee EG; Kim SW; Chisholm WP; Kashon M; Harper M
Ann Occup Hyg; 2012 May; 56(4):413-25. PubMed ID: 22186376
[TBL] [Abstract][Full Text] [Related]
6. A comparison of the performance of samplers for respirable dust in workplaces and laboratory analysis for respirable quartz.
Verpaele S; Jouret J
Ann Occup Hyg; 2013 Jan; 57(1):54-62. PubMed ID: 22826536
[TBL] [Abstract][Full Text] [Related]
7. Determinants of respirable crystalline silica exposure among stoneworkers involved in stone restoration work.
Healy CB; Coggins MA; Van Tongeren M; MacCalman L; McGowan P
Ann Occup Hyg; 2014 Jan; 58(1):6-18. PubMed ID: 23997236
[TBL] [Abstract][Full Text] [Related]
8. An evaluation of on-tool shrouds for controlling respirable crystalline silica in restoration stone work.
Healy CB; Coggins MA; Van Tongeren M; MacCalman L; McGowan P
Ann Occup Hyg; 2014 Nov; 58(9):1155-67. PubMed ID: 25261456
[TBL] [Abstract][Full Text] [Related]
9. Performance of High Flow Rate Personal Respirable Samplers When Challenged with Mineral Aerosols of Different Particle Size Distributions.
Stacey P; Thorpe A; Echt A
Ann Occup Hyg; 2016 May; 60(4):479-92. PubMed ID: 26865560
[TBL] [Abstract][Full Text] [Related]
10. Respirable concrete dust--silicosis hazard in the construction industry.
Linch KD
Appl Occup Environ Hyg; 2002 Mar; 17(3):209-21. PubMed ID: 11871757
[TBL] [Abstract][Full Text] [Related]
11. Respirable size-selective sampler for end-of-shift quartz measurement: Development and performance.
Lee T; Lee L; Cauda E; Hummer J; Harper M
J Occup Environ Hyg; 2017 May; 14(5):335-342. PubMed ID: 27792471
[TBL] [Abstract][Full Text] [Related]
12. Exposures of geotechnical laboratory workers to respirable crystalline silica.
Miller SK; Bigelow PL; Sharp-Geiger R; Buchan RM
Appl Occup Environ Hyg; 1999 Jan; 14(1):39-44. PubMed ID: 10730137
[TBL] [Abstract][Full Text] [Related]
13. Quartz in coal dust deposited on internal surface of respirable size selective samplers.
Soo JC; Lee T; Kashon M; Kusti M; Harper M
J Occup Environ Hyg; 2014; 11(12):D215-9. PubMed ID: 25204985
[TBL] [Abstract][Full Text] [Related]
14. Occupational Exposures in an Equestrian Centre to Respirable Dust and Respirable Crystalline Silica.
Bulfin K; Cowie H; Galea KS; Connolly A; Coggins MA
Int J Environ Res Public Health; 2019 Sep; 16(17):. PubMed ID: 31484444
[TBL] [Abstract][Full Text] [Related]
15. Estimating historical respirable crystalline silica exposures for Chinese pottery workers and iron/copper, tin, and tungsten miners.
Zhuang Z; Hearl FJ; Odencrantz J; Chen W; Chen BT; Chen JQ; McCawley MA; Gao P; Soderholm SC
Ann Occup Hyg; 2001 Nov; 45(8):631-42. PubMed ID: 11718659
[TBL] [Abstract][Full Text] [Related]
16. Field evaluation of an engineering control for respirable crystalline silica exposures during mortar removal.
Collingwood S; Heitbrink WA
J Occup Environ Hyg; 2007 Nov; 4(11):875-87. PubMed ID: 17917951
[TBL] [Abstract][Full Text] [Related]
17. Calibration of high flow rate thoracic-size selective samplers.
Lee T; Thorpe A; Cauda E; Harper M
J Occup Environ Hyg; 2016; 13(6):D93-8. PubMed ID: 26891196
[TBL] [Abstract][Full Text] [Related]
18. Exposure to Respirable Crystalline Silica in the GB Brick Manufacturing and Stone Working Industries.
Baldwin PEJ; Yates T; Beattie H; Keen C; Warren N
Ann Work Expo Health; 2019 Feb; 63(2):184-196. PubMed ID: 30624605
[TBL] [Abstract][Full Text] [Related]
19. Comparison of respirable dust samplers for use in hard rock mines.
Knight G; Moore E
Am Ind Hyg Assoc J; 1987 Apr; 48(4):354-63. PubMed ID: 3591651
[TBL] [Abstract][Full Text] [Related]
20. Validation of the analysis of respirable crystalline silica (quartz) in foams used with CIP 10-R samplers.
Eypert-Blaison C; Moulut JC; Lecaque T; Marc F; Kauffer E
Ann Occup Hyg; 2011 May; 55(4):357-68. PubMed ID: 21257743
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]