These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 26953180)

  • 1. On Holo-Hilbert spectral analysis: a full informational spectral representation for nonlinear and non-stationary data.
    Huang NE; Hu K; Yang AC; Chang HC; Jia D; Liang WK; Yeh JR; Kao CL; Juan CH; Peng CK; Meijer JH; Wang YH; Long SR; Wu Z
    Philos Trans A Math Phys Eng Sci; 2016 Apr; 374(2065):20150206. PubMed ID: 26953180
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Full Informational Spectral Analysis for Auditory Steady-State Responses in Human Brain Using the Combination of Canonical Correlation Analysis and Holo-Hilbert Spectral Analysis.
    Lee PL; Lee TM; Lee WK; Chu NN; Shelepin YE; Hsu HT; Chang HH
    J Clin Med; 2022 Jul; 11(13):. PubMed ID: 35807153
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Order-frequency Holo-Hilbert spectral analysis for machinery fault diagnosis under time-varying operating conditions.
    Ying W; Zheng J; Huang W; Tong J; Pan H; Li Y
    ISA Trans; 2024 Mar; 146():472-483. PubMed ID: 38311494
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hilbert-Huang transformation-based time-frequency analysis methods in biomedical signal applications.
    Lin CF; Zhu JD
    Proc Inst Mech Eng H; 2012 Mar; 226(3):208-16. PubMed ID: 22558835
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Revealing the Dynamic Nature of Amplitude Modulated Neural Entrainment With Holo-Hilbert Spectral Analysis.
    Juan CH; Nguyen KT; Liang WK; Quinn AJ; Chen YH; Muggleton NG; Yeh JR; Woolrich MW; Nobre AC; Huang NE
    Front Neurosci; 2021; 15():673369. PubMed ID: 34421511
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Time-frequency analysis of non-stationary fusion plasma signals using an improved Hilbert-Huang transform.
    Liu Y; Tan Y; Xie H; Wang W; Gao Z
    Rev Sci Instrum; 2014 Jul; 85(7):073502. PubMed ID: 25085135
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spectral Analysis of Electricity Demand Using Hilbert-Huang Transform.
    Luque J; Anguita D; Pérez F; Denda R
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32455613
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Holo-Hilbert spectral-based noise removal method for EEG high-frequency bands.
    Moradi N; LeVan P; Akin B; Goodyear BG; Sotero RC
    J Neurosci Methods; 2022 Feb; 368():109470. PubMed ID: 34973273
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Time-frequency analysis of pupil size modulated by global luminance, arousal, and saccade preparation signals using Hilbert-Huang transform.
    Nguyen KT; Liang WK; Juan CH; Wang CA
    Int J Psychophysiol; 2022 Jun; 176():89-99. PubMed ID: 35367510
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detecting position dependent tremor with the Empirical mode decomposition.
    Lee A; Altenmüller E
    J Clin Mov Disord; 2015; 2():3. PubMed ID: 26788339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wearable Sensor-Based Human Activity Recognition Method with Multi-Features Extracted from Hilbert-Huang Transform.
    Xu H; Liu J; Hu H; Zhang Y
    Sensors (Basel); 2016 Dec; 16(12):. PubMed ID: 27918414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Structural Damage Localization and Quantification Based on a CEEMDAN Hilbert Transform Neural Network Approach: A Model Steel Truss Bridge Case Study.
    Mousavi AA; Zhang C; Masri SF; Gholipour G
    Sensors (Basel); 2020 Feb; 20(5):. PubMed ID: 32110964
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Motion Capture Data Analysis in the Instantaneous Frequency-Domain Using Hilbert-Huang Transform.
    Dong R; Cai D; Ikuno S
    Sensors (Basel); 2020 Nov; 20(22):. PubMed ID: 33207544
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mean frequency derived via Hilbert-Huang transform with application to fatigue EMG signal analysis.
    Xie H; Wang Z
    Comput Methods Programs Biomed; 2006 May; 82(2):114-20. PubMed ID: 16616796
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spectral denoising based on Hilbert-Huang transform combined with F-test.
    Bian X; Ling M; Chu Y; Liu P; Tan X
    Front Chem; 2022; 10():949461. PubMed ID: 36110141
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analyses of EEG Oscillatory Activities during Slow and Fast Repetitive Movements using Holo-Hilbert Spectral Analysis.
    Hsu HT; Lee WK; Shyu KK; Yeh TK; Chang CY; Lee PL
    IEEE Trans Neural Syst Rehabil Eng; 2018 Jul; ():. PubMed ID: 30010582
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Investigating Power Density and the Degree of Nonlinearity in Intrinsic Components of Anesthesia EEG by the Hilbert-Huang Transform: An Example Using Ketamine and Alfentanil.
    Tsai FF; Fan SZ; Lin YS; Huang NE; Yeh JR
    PLoS One; 2016; 11(12):e0168108. PubMed ID: 27973590
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Time-frequency analysis of neuronal populations with instantaneous resolution based on noise-assisted multivariate empirical mode decomposition.
    Alegre-Cortés J; Soto-Sánchez C; Pizá ÁG; Albarracín AL; Farfán FD; Felice CJ; Fernández E
    J Neurosci Methods; 2016 Jul; 267():35-44. PubMed ID: 27044801
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SU-E-J-143: Characteristics of Tumor-Motion Surrogate Signals Analyzed Using Empirical Mode Decomposition and Hilbert-Huang Transformation.
    Han-Oh S
    Med Phys; 2012 Jun; 39(6Part8):3685. PubMed ID: 28518947
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Frequency analysis of eyes open and eyes closed EEG signals using the Hilbert-Huang transform.
    Thuraisingham RA; Tran Y; Craig A; Nguyen H
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():2865-8. PubMed ID: 23366522
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.