148 related articles for article (PubMed ID: 26966030)
1. [How to assess the neutral position of the fetus for the crown-rump length measurement at the nuchal translucency scan].
Roux N; Dhombres F; Friszer S; Jouannic JM
Gynecol Obstet Fertil; 2016 Mar; 44(3):146-50. PubMed ID: 26966030
[TBL] [Abstract][Full Text] [Related]
2. Quality of first-trimester measurement of crown-rump length.
Dhombres F; Khoshnood B; Bessis R; Fries N; Senat MV; Jouannic JM
Am J Obstet Gynecol; 2014 Dec; 211(6):672.e1-5. PubMed ID: 24912098
[TBL] [Abstract][Full Text] [Related]
3. [A simple self-assessment tool for the first-trimester ultrasound images].
Dhombres F; Friszer S; Bessis R; Jouannic JM
Gynecol Obstet Fertil; 2015 Dec; 43(12):761-6. PubMed ID: 26476892
[TBL] [Abstract][Full Text] [Related]
4. Relation between the quality of the ultrasound image acquisition and the precision of the measurement of the crown-rump length in the late first trimester: what are the consequences?
Dhombres F; Roux N; Friszer S; Bessis R; Khoshnood B; Jouannic JM
Eur J Obstet Gynecol Reprod Biol; 2016 Dec; 207():37-44. PubMed ID: 27816740
[TBL] [Abstract][Full Text] [Related]
5. Nuchal translucency in normal fetus and its variation with increasing crown rump length (CRL) and gestational age.
Karki S; Joshi KS; Tamrakar SR; Regmi S; Khanal K
Kathmandu Univ Med J (KUMJ); 2013; 11(44):282-6. PubMed ID: 24899320
[TBL] [Abstract][Full Text] [Related]
6. Visualization of intracranial translucency at the 11-13-week scan is improved after specific training.
Mangione R; Lelong N; Fontanges M; Amat S; Rosenblatt J; Khoshnood B; Jouannic JM
Ultrasound Obstet Gynecol; 2011 Dec; 38(6):635-9. PubMed ID: 21998023
[TBL] [Abstract][Full Text] [Related]
7. Detection of fetal structural anomalies in a basic first-trimester screening program for aneuploidy.
Bromley B; Shipp TD; Lyons J; Navathe RS; Groszmann Y; Benacerraf BR
J Ultrasound Med; 2014 Oct; 33(10):1737-45. PubMed ID: 25253819
[TBL] [Abstract][Full Text] [Related]
8. Relationship between fetal nuchal translucency and crown-rump length in an Asian population.
Jou HJ; Wu SC; Li TC; Hsu HC; Tzeng CY; Hsieh FJ
Ultrasound Obstet Gynecol; 2001 Feb; 17(2):111-4. PubMed ID: 11251917
[TBL] [Abstract][Full Text] [Related]
9. Ultrasonographic study of fetal facial profile markers during the first trimester.
Ji C; Jiang X; Yin L; Deng X; Yang Z; Pan Q; Zhang J; Liang Q
BMC Pregnancy Childbirth; 2021 Apr; 21(1):324. PubMed ID: 33894762
[TBL] [Abstract][Full Text] [Related]
10. Lack of correlation between first trimester maternal serum 25-hydroxyvitamin D levels and ultrasound measured crown-rump length and nuchal translucency.
Fernández-Alonso AM; Fiol-Ruiz G; Chedraui P; Pérez-López FR
Arch Gynecol Obstet; 2011 Dec; 284(6):1585-8. PubMed ID: 21877143
[TBL] [Abstract][Full Text] [Related]
11. Image-scoring system for crown-rump length measurement.
Wanyonyi SZ; Napolitano R; Ohuma EO; Salomon LJ; Papageorghiou AT
Ultrasound Obstet Gynecol; 2014 Dec; 44(6):649-54. PubMed ID: 24677327
[TBL] [Abstract][Full Text] [Related]
12. Optimal crown-rump length for measuring the nuchal translucency.
Wax JR; Pinette MG; Cartin A; Blackstone J
J Clin Ultrasound; 2007; 35(6):302-4. PubMed ID: 17486568
[TBL] [Abstract][Full Text] [Related]
13. [Distribution and normal reference range of fetal nuchal translucency thickness in Kunming pregnant women in the first trimester].
Sun Q; Xu J; Hu SQ; Chen M; Ma RM; Lau TK; Zhang L; Xiao X; Qian Y; Guo Z
Zhonghua Fu Chan Ke Za Zhi; 2012 Jul; 47(7):514-7. PubMed ID: 23141162
[TBL] [Abstract][Full Text] [Related]
14. Fetal echocardiography at the time of the nuchal translucency scan.
Lombardi CM; Bellotti M; Fesslova V; Cappellini A
Ultrasound Obstet Gynecol; 2007 Mar; 29(3):249-57. PubMed ID: 17318942
[TBL] [Abstract][Full Text] [Related]
15. What information on fetal anatomy can be provided by a single first-trimester transabdominal three-dimensional sweep?
Fauchon DE; Benzie RJ; Wye DA; Cairns DR
Ultrasound Obstet Gynecol; 2008 Mar; 31(3):266-70. PubMed ID: 18307174
[TBL] [Abstract][Full Text] [Related]
16. Isolated Cleft Lip and Palate: Maxillary Gap Sign and Palatino-Maxillary Diameter at 11-13 Weeks.
Lachmann R; Schilling U; Brückmann D; Weichert A; Brückmann A
Fetal Diagn Ther; 2018; 44(4):241-246. PubMed ID: 29073631
[TBL] [Abstract][Full Text] [Related]
17. Impact of bias in crown-rump length measurement at first-trimester screening for trisomy 21.
Kagan KO; Hoopmann M; Baker A; Huebner M; Abele H; Wright D
Ultrasound Obstet Gynecol; 2012 Aug; 40(2):135-9. PubMed ID: 22262465
[TBL] [Abstract][Full Text] [Related]
18. Fetal nuchal translucency screening in 12495 pregnancies in Sardinia.
Zoppi MA; Ibba RM; Floris M; Monni G
Ultrasound Obstet Gynecol; 2001 Dec; 18(6):649-51. PubMed ID: 11844208
[TBL] [Abstract][Full Text] [Related]
19. Clinical implications of intra- and interobserver reproducibility of transvaginal sonographic measurement of gestational sac and crown-rump length at 6-9 weeks' gestation.
Pexsters A; Luts J; Van Schoubroeck D; Bottomley C; Van Calster B; Van Huffel S; Abdallah Y; D'Hooghe T; Lees C; Timmerman D; Bourne T
Ultrasound Obstet Gynecol; 2011 Nov; 38(5):510-5. PubMed ID: 21077156
[TBL] [Abstract][Full Text] [Related]
20. Fetal Crown-Chin Length to Crown-Rump Length Ratio as a Prenatal Sonographic Marker for Triploidy at First Trimester.
Yang X; Li Y; Wu S; Du K; Li D; Liao C
J Ultrasound Med; 2022 Mar; 41(3):679-684. PubMed ID: 34018626
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]