These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 26969205)

  • 1. Is determination of the hip rotation center during computer-assisted surgery influenced by the pinless femoral sensor attachment method? An in vitro preliminary study comparing osseous pin fixation.
    de Thomasson E; Gouzy S; Cloerec F; Geais L
    Orthop Traumatol Surg Res; 2016 May; 102(3):375-8. PubMed ID: 26969205
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental validation of a pinless femoral reference array for computer-assisted hip arthroplasty.
    Renkawitz T; Wegner M; Gneiting S; Haimerl M; Sendtner E; Kalteis T; Grifka J
    J Orthop Res; 2010 May; 28(5):583-8. PubMed ID: 19950361
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of Leg Length and Offset Restoration in Femoral Pinless Navigation Compared to Navigation Using a Fixed Pin during Total Hip Arthroplasty.
    Weber M; Thieme M; Kaiser M; Völlner F; Worlicek M; Craiovan B; Grifka J; Renkawitz T
    Biomed Res Int; 2018; 2018():1639840. PubMed ID: 30046589
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Leg length and offset measures with a pinless femoral reference array during THA.
    Renkawitz T; Schuster T; Grifka J; Kalteis T; Sendtner E
    Clin Orthop Relat Res; 2010 Jul; 468(7):1862-8. PubMed ID: 19768517
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In-vitro investigation of a noninvasive referencing technology for computer-assisted total hip arthroplasty.
    Renkawitz T; Gneiting S; Schaumburger J; Woerner M; Springorum HR; Grifka J; Schuster T; Sendtner E
    Orthopedics; 2010 Apr; 33(4):. PubMed ID: 20415298
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: prospective study with the EOS imaging system.
    Barbier O; Skalli W; Mainard L; Mainard D;
    Orthop Traumatol Surg Res; 2014 Oct; 100(6 Suppl):S287-91. PubMed ID: 25129705
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of fixation and location on the stability of the markers in navigated total hip arthroplasty: a cadaver study.
    Mayr E; de la Barrera JL; Eller G; Bach C; Nogler M
    J Bone Joint Surg Br; 2006 Feb; 88(2):168-72. PubMed ID: 16434518
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pin Site Complications Associated With Computer-Assisted Navigation in Hip and Knee Arthroplasty.
    Kamara E; Berliner ZP; Hepinstall MS; Cooper HJ
    J Arthroplasty; 2017 Sep; 32(9):2842-2846. PubMed ID: 28522245
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Skeletal landmarks for TKR implantations: evaluation of their accuracy using EOS imaging acquisition system.
    Schlatterer B; Suedhoff I; Bonnet X; Catonne Y; Maestro M; Skalli W
    Orthop Traumatol Surg Res; 2009 Feb; 95(1):2-11. PubMed ID: 19251231
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pelvic tilt measurement before and after total hip arthroplasty.
    Blondel B; Parratte S; Tropiano P; Pauly V; Aubaniac JM; Argenson JN
    Orthop Traumatol Surg Res; 2009 Dec; 95(8):568-72. PubMed ID: 19910273
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Morbidity and Safety of Iliac Crest Reference Array Pins in Navigated Total Hip Arthroplasty: A Prospective Cohort Study.
    Lambers AP; Salim XG; Jennings R; Bucknill AT
    J Arthroplasty; 2018 May; 33(5):1557-1561. PubMed ID: 29352689
    [TBL] [Abstract][Full Text] [Related]  

  • 12. What is the best hip center location method to compute HKA angle in computer-assisted orthopedic surgery? In silico and in vitro comparison of four methods.
    Dardenne G; Dib Z; Poirier N; Letissier H; Lefèvre C; Stindel E
    Orthop Traumatol Surg Res; 2019 Feb; 105(1):55-61. PubMed ID: 30573397
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Influence of Hip Rotation on Femoral Offset Following Short Stem Total Hip Arthroplasty.
    Boese CK; Bredow J; Ettinger M; Eysel P; Thorey F; Lechler P; Budde S
    J Arthroplasty; 2016 Jan; 31(1):312-6. PubMed ID: 26271542
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Plain radiographs fail to reflect femoral offset in total hip arthroplasty.
    Weber M; Woerner ML; Springorum HR; Hapfelmeier A; Grifka J; Renkawitz TF
    J Arthroplasty; 2014 Aug; 29(8):1661-5. PubMed ID: 24857334
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transepicondylar distal femoral pin placement in computer assisted surgical navigation.
    Stiehl JB
    Comput Aided Surg; 2007 Jul; 12(4):242-6. PubMed ID: 17786600
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating.
    Sariali E; Mauprivez R; Khiami F; Pascal-Mousselard H; Catonné Y
    Orthop Traumatol Surg Res; 2012 Apr; 98(2):151-8. PubMed ID: 22381566
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.
    Lin F; Lim D; Wixson RL; Milos S; Hendrix RW; Makhsous M
    Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):1004-11. PubMed ID: 18541352
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of cutaneous and transosseous electromagnetic position sensors in the assessment of tibial rotation in a cadaveric model.
    Magit DP; McGarry M; Tibone JE; Lee TQ
    Am J Sports Med; 2008 May; 36(5):971-7. PubMed ID: 18272792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pin track induced fractures around computer-assisted TKA.
    Beldame J; Boisrenoult P; Beaufils P
    Orthop Traumatol Surg Res; 2010 May; 96(3):249-55. PubMed ID: 20488143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Even the Intraoperative Knowledge of Femoral Stem Anteversion Cannot Prevent Impingement in Total Hip Arthroplasty.
    Weber M; Woerner ML; Sendtner E; Völlner F; Grifka J; Renkawitz TF
    J Arthroplasty; 2016 Nov; 31(11):2514-2519. PubMed ID: 27236745
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.