These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Self-calibrated GRAPPA method for 2D and 3D radial data. Arunachalam A; Samsonov A; Block WF Magn Reson Med; 2007 May; 57(5):931-8. PubMed ID: 17457884 [TBL] [Abstract][Full Text] [Related]
24. Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine. Li S; Chan C; Stockmann JP; Tagare H; Adluru G; Tam LK; Galiana G; Constable RT; Kozerke S; Peters DC Magn Reson Med; 2015 Apr; 73(4):1643-53. PubMed ID: 24753213 [TBL] [Abstract][Full Text] [Related]
25. Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA. Seiberlich N; Lee G; Ehses P; Duerk JL; Gilkeson R; Griswold M Magn Reson Med; 2011 Dec; 66(6):1682-8. PubMed ID: 21523823 [TBL] [Abstract][Full Text] [Related]
26. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Griswold MA; Jakob PM; Heidemann RM; Nittka M; Jellus V; Wang J; Kiefer B; Haase A Magn Reson Med; 2002 Jun; 47(6):1202-10. PubMed ID: 12111967 [TBL] [Abstract][Full Text] [Related]
27. Sparsity adaptive reconstruction for highly accelerated cardiac MRI. Chen C; Liu Y; Schniter P; Jin N; Craft J; Simonetti O; Ahmad R Magn Reson Med; 2019 Jun; 81(6):3875-3887. PubMed ID: 30666694 [TBL] [Abstract][Full Text] [Related]
28. Cardiac magnetic resonance imaging using radial k-space sampling and self-calibrated partial parallel reconstruction. Xie J; Lai P; Huang F; Li Y; Li D Magn Reson Imaging; 2010 May; 28(4):495-506. PubMed ID: 20061114 [TBL] [Abstract][Full Text] [Related]
29. GRAPPA operator for wider radial bands (GROWL) with optimally regularized self-calibration. Lin W; Huang F; Li Y; Reykowski A Magn Reson Med; 2010 Sep; 64(3):757-66. PubMed ID: 20806377 [TBL] [Abstract][Full Text] [Related]
30. Reconstruction of undersampled non-Cartesian data sets using pseudo-Cartesian GRAPPA in conjunction with GROG. Seiberlich N; Breuer F; Heidemann R; Blaimer M; Griswold M; Jakob P Magn Reson Med; 2008 May; 59(5):1127-37. PubMed ID: 18429026 [TBL] [Abstract][Full Text] [Related]
31. Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding. Deshmane A; Blaimer M; Breuer F; Jakob P; Duerk J; Seiberlich N; Griswold M Magn Reson Med; 2016 Feb; 75(2):883-96. PubMed ID: 25765372 [TBL] [Abstract][Full Text] [Related]
32. Whole-heart cine MRI in a single breath-hold--a compressed sensing accelerated 3D acquisition technique for assessment of cardiac function. Wech T; Pickl W; Tran-Gia J; Ritter C; Beer M; Hahn D; Köstler H Rofo; 2014 Jan; 186(1):37-41. PubMed ID: 23996623 [TBL] [Abstract][Full Text] [Related]