  • 1. Clinical utilization of arterial occlusion pressure estimation method in lower limb surgery: effectiveness of tourniquet pressures.
    Tuncalı B; Boya H; Kayhan Z; Araç Ş; Çamurdan MA
    Acta Orthop Traumatol Turc; 2016; 50(2):171-7. PubMed ID: 26969952
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tourniquet pressure settings based on limb occlusion pressure determination or arterial occlusion pressure estimation in total knee arthroplasty? A prospective, randomized, double blind trial.
    Tuncali B; Boya H; Kayhan Z; Arac S
    Acta Orthop Traumatol Turc; 2018 Jul; 52(4):256-260. PubMed ID: 29752149
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Obese patients require higher, but not high pneumatic tourniquet inflation pressures using a novel technique during total knee arthroplasty.
    Tuncalı B; Boya H; Kayhan Z; Araç Ş
    Eklem Hastalik Cerrahisi; 2018 Apr; 29(1):40-5. PubMed ID: 29526158
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of arterial occlusion pressure estimation-based tourniquet pressure settings in upper limb surgery.
    Tuncali B; Kokten G; Boya H; Altinel F; Kayhan Z
    J Orthop Sci; 2022 Sep; 27(5):1051-1055. PubMed ID: 34315653
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison between two mathematical methods to estimate arterial occlusion pressure and tourniquet effectiveness in lower limb surgery: a prospective, randomized, double blind, comparative study.
    Kasem SA; Al Menesy T; Badawy AA; Abd Elmawgoud A; Adel G; Badawy YA
    J Clin Monit Comput; 2020 Aug; 34(4):675-681. PubMed ID: 31346900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method for estimating arterial occlusion pressure in optimizing pneumatic tourniquet inflation pressure.
    Tuncali B; Karci A; Tuncali BE; Mavioglu O; Ozkan M; Bacakoglu AK; Baydur H; Ekin A; Elar Z
    Anesth Analg; 2006 Jun; 102(6):1752-7. PubMed ID: 16717321
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of lower tourniquet inflation pressures in extremity surgery facilitated by curved and wide tourniquets and an integrated cuff inflation system.
    Pedowitz RA; Gershuni DH; Botte MJ; Kuiper S; Rydevik BL; Hargens AR
    Clin Orthop Relat Res; 1993 Feb; (287):237-44. PubMed ID: 8448950
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimal Inflation Tourniquet Pressure Using Induced Hypotension with Limb Occlusion Pressure Determination or Arterial Occlusion Pressure Estimation in Upper Limb Surgery: A Randomized Double-Blinded Comparative Study.
    Kasem SA; Bassiouny AAE; Rashwan DAE; Bahr MH
    Anesth Pain Med; 2020 Apr; 10(2):e102124. PubMed ID: 32754434
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Controlled hypotension and minimal inflation pressure: a new approach for pneumatic tourniquet application in upper limb surgery.
    Tuncali B; Karci A; Bacakoglu AK; Tuncali BE; Ekin A
    Anesth Analg; 2003 Nov; 97(5):1529-1532. PubMed ID: 14570681
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lower tourniquet cuff pressure reduces postoperative wound complications after total knee arthroplasty: a randomized controlled study of 164 patients.
    Olivecrona C; Ponzer S; Hamberg P; Blomfeldt R
    J Bone Joint Surg Am; 2012 Dec; 94(24):2216-21. PubMed ID: 23318611
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new tourniquet system that determines pressures in synchrony with systolic blood pressure.
    Ishii Y; Noguchi H; Matsuda Y; Takeda M; Higashihara T
    Arch Orthop Trauma Surg; 2008 Mar; 128(3):297-300. PubMed ID: 17874247
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Occlusion of arterial flow in the extremities at subsystolic pressures through the use of wide tourniquet cuffs.
    Graham B; Breault MJ; McEwen JA; McGraw RW
    Clin Orthop Relat Res; 1993 Jan; (286):257-61. PubMed ID: 8425355
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of adaptive pneumatic tourniquet systems based on minimal inflation pressure for upper limb surgeries.
    Liu HY; Guo JY; Zhang ZB; Li KY; Wang WD
    Biomed Eng Online; 2013 Sep; 12():92. PubMed ID: 24053348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 'The BloodStopper' - experiences with a novel portable hand-held orthopaedic limb tourniquet.
    Millar TM; McGrath P; McConnachie CC
    Trop Doct; 2007 Oct; 37(4):202-3. PubMed ID: 17988474
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated cuff occlusion pressure effect on quality of operative fields in foot and ankle surgery: a randomized prospective study.
    Younger AS; Manzary M; Wing KJ; Stothers K
    Foot Ankle Int; 2011 Mar; 32(3):239-43. PubMed ID: 21477541
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimizing tourniquet pressure in pediatric anterior cruciate ligament reconstructive surgery: a blinded, prospective randomized controlled trial.
    Reilly CW; McEwen JA; Leveille L; Perdios A; Mulpuri K
    J Pediatr Orthop; 2009; 29(3):275-80. PubMed ID: 19305279
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new tourniquet system that determines pressures in synchrony with systolic blood pressure in knee surgery.
    Ishii Y; Noguchi H; Takeda M; Higashihara T
    Knee Surg Sports Traumatol Arthrosc; 2009 Jan; 17(1):48-52. PubMed ID: 18830581
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wide contoured thigh cuffs and automated limb occlusion measurement allow lower tourniquet pressures.
    Younger AS; McEwen JA; Inkpen K
    Clin Orthop Relat Res; 2004 Nov; (428):286-93. PubMed ID: 15534554
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dexmedetomidine attenuates tourniquet-induced hyperdynamic response in patients undergoing lower limb surgeries: a randomized controlled study.
    Lao HC; Tsai PS; Su JY; Kwok TG; Huang CJ
    J Surg Res; 2013 Jan; 179(1):e99-e106. PubMed ID: 22487388
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimal tourniquet pressure to maintain arterial closure in upper limb surgery.
    Levy O; David Y; Heim M; Eldar I; Chetrit A; Engel J
    J Hand Surg Br; 1993 Apr; 18(2):204-6. PubMed ID: 8501377
    [TBL] [Abstract][Full Text] [Related]  