BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 26975735)

  • 1. Organ doses can be estimated from the computed tomography (CT) dose index for cone-beam CT on radiotherapy equipment.
    Martin CJ; Abuhaimed A; Sankaralingam M; Metwaly M; Gentle DJ
    J Radiol Prot; 2016 Jun; 36(2):215-29. PubMed ID: 26975735
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Monte Carlo study of organ and effective doses of cone beam computed tomography (CBCT) scans in radiotherapy.
    Abuhaimed A; Martin CJ; Sankaralingam M
    J Radiol Prot; 2018 Mar; 38(1):61-80. PubMed ID: 28952463
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.
    Baptista M; Di Maria S; Vieira S; Santos J; Pereira J; Pereira M; Vaz P
    Radiat Environ Biophys; 2019 Mar; 58(1):21-37. PubMed ID: 30392077
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.
    Abuhaimed A; Martin CJ; Sankaralingam M; Gentle DJ
    Phys Med Biol; 2015 Jul; 60(14):5413-38. PubMed ID: 26118740
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pediatric cone beam CT on Varian Halcyon and TrueBeam radiotherapy systems: radiation dose and positioning accuracy evaluations.
    Huang Y; Du Y; Li C; Wang H; Zu Z; Feng Z; Zhou S; Wu H; Zhang Y
    J Radiol Prot; 2019 Sep; 39(3):739-748. PubMed ID: 31042686
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimation of effective imaging dose and excess absolute risk of secondary cancer incidence for four-dimensional cone-beam computed tomography acquisition.
    Yuasa Y; Shiinoki T; Onizuka R; Fujimoto K
    J Appl Clin Med Phys; 2019 Nov; 20(11):57-68. PubMed ID: 31593377
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies.
    Buckley JG; Wilkinson D; Malaroda A; Metcalfe P
    J Appl Clin Med Phys; 2018 Jan; 19(1):174-183. PubMed ID: 29265684
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT.
    Rampado O; Giglioli FR; Rossetti V; Fiandra C; Ragona R; Ropolo R
    Med Phys; 2016 May; 43(5):2515. PubMed ID: 27147362
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of cone beam CT (CBCT) scan parameters on size specific dose estimate (SSDE): a Monte Carlo study.
    Abuhaimed A; Martin CJ; Demirkaya O
    Phys Med Biol; 2019 May; 64(11):115002. PubMed ID: 30822764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy.
    Hioki K; Araki F; Ohno T; Nakaguchi Y; Tomiyama Y
    Phys Med Biol; 2014 Dec; 59(23):7297-313. PubMed ID: 25383908
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental validation of a kV source model and dose computation method for CBCT imaging in an anthropomorphic phantom.
    Poirier Y; Tambasco M
    J Appl Clin Med Phys; 2016 Jul; 17(4):155-171. PubMed ID: 27455477
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of coefficients to derive organ and effective doses from cone-beam CT (CBCT) scans: a Monte Carlo study.
    Abuhaimed A; Martin CJ
    J Radiol Prot; 2018 Mar; 38(1):189-206. PubMed ID: 29154259
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computed tomography dose index and dose length product for cone-beam CT: Monte Carlo simulations.
    Kim S; Song H; Samei E; Yin FF; Yoshizumi TT
    J Appl Clin Med Phys; 2011 Jan; 12(2):3395. PubMed ID: 21587186
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of computed tomography dose index in cone beam computed tomography: MOSFET measurements and Monte Carlo simulations.
    Kim S; Yoshizumi T; Toncheva G; Yoo S; Yin FF; Frush D
    Health Phys; 2010 May; 98(5):683-91. PubMed ID: 20386198
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols.
    Kim S; Yoo S; Yin FF; Samei E; Yoshizumi T
    Med Phys; 2010 Jul; 37(7):3648-59. PubMed ID: 20831072
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An investigation of image guidance dose for breast radiotherapy.
    Alvarado R; Booth JT; Bromley RM; Gustafsson HB
    J Appl Clin Med Phys; 2013 May; 14(3):4085. PubMed ID: 23652243
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comprehensive Monte Carlo study of patient doses from cone-beam CT imaging in radiotherapy.
    Marchant TE; Joshi KD
    J Radiol Prot; 2017 Mar; 37(1):13-30. PubMed ID: 27922831
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Variation of patient imaging doses with scanning parameters for linac-integrated kilovoltage cone beam CT.
    Liao X; Wang Y; Lang J; Wang P; Li J; Ge R; Yang J
    Biomed Mater Eng; 2015; 26 Suppl 1():S1659-67. PubMed ID: 26405932
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose.
    Ding GX; Munro P
    Radiother Oncol; 2013 Jul; 108(1):91-8. PubMed ID: 23830468
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of radiation dose and image quality for the Varian cone beam computed tomography system.
    Cheng HC; Wu VW; Liu ES; Kwong DL
    Int J Radiat Oncol Biol Phys; 2011 May; 80(1):291-300. PubMed ID: 20932676
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.