These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 26977342)

  • 1. High frame rate photoacoustic imaging at 7000 frames per second using clinical ultrasound system.
    Sivasubramanian K; Pramanik M
    Biomed Opt Express; 2016 Feb; 7(2):312-23. PubMed ID: 26977342
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fast photoacoustic imaging systems using pulsed laser diodes: a review.
    Upputuri PK; Pramanik M
    Biomed Eng Lett; 2018 May; 8(2):167-181. PubMed ID: 30603201
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system.
    Upputuri PK; Pramanik M
    Biomed Opt Express; 2015 Oct; 6(10):4118-29. PubMed ID: 26504659
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-speed, low-cost, pulsed-laser-diode-based second-generation desktop photoacoustic tomography system.
    Kalva SK; Upputuri PK; Pramanik M
    Opt Lett; 2019 Jan; 44(1):81-84. PubMed ID: 30645563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental evaluation of photoacoustic coded excitation using unipolar golay codes.
    Mienkina MP; Friedrich CS; Gerhardt NC; Wilkening WG; Hofmann MR; Schmitz G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Jul; 57(7):1583-93. PubMed ID: 20639152
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 2  MHz multi-wavelength pulsed laser for functional photoacoustic microscopy.
    Liang Y; Jin L; Guan BO; Wang L
    Opt Lett; 2017 Apr; 42(7):1452-1455. PubMed ID: 28362790
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo near-realtime volumetric optical-resolution photoacoustic microscopy using a high-repetition-rate nanosecond fiber-laser.
    Shi W; Hajireza P; Shao P; Forbrich A; Zemp RJ
    Opt Express; 2011 Aug; 19(18):17143-50. PubMed ID: 21935076
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Photoacoustic Imaging of Human Vasculature Using LED versus Laser Illumination: A Comparison Study on Tissue Phantoms and In Vivo Humans.
    Agrawal S; Kuniyil Ajith Singh M; Johnstonbaugh K; C Han D; R Pameijer C; Kothapalli SR
    Sensors (Basel); 2021 Jan; 21(2):. PubMed ID: 33435375
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optical Resolution Photoacoustic Microscopy With Fast Laser Scanning and Fixed Photoacoustic Detector
    Ishikawa K; Shintate R; Nagaoka R; Saijo Y
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():4800-4803. PubMed ID: 30441420
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Extending Imaging Depth in PLD-Based Photoacoustic Imaging: Moving Beyond Averaging.
    Chandramoorthi S; Thittai AK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Mar; 68(3):549-557. PubMed ID: 32784132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Low-Cost Multi-Wavelength Photoacoustic Imaging Based on Portable Continuous-Wave Laser Diode Module.
    Zhong H; Jiang D; Lan H; Duan T; Gao F; Gao F
    IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):738-745. PubMed ID: 32746335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time interleaved photoacoustic/ultrasound (PAUS) imaging for interventional procedure guidance.
    Wei CW; Nguyen TM; Xia J; Arnal B; Pelivanov I; O'Donnell M
    Proc SPIE Int Soc Opt Eng; 2015 Feb; 9323():. PubMed ID: 36247362
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-speed intravascular photoacoustic imaging at 1.7 μm with a KTP-based OPO.
    Hui J; Yu Q; Ma T; Wang P; Cao Y; Bruning RS; Qu Y; Chen Z; Zhou Q; Sturek M; Cheng JX; Chen W
    Biomed Opt Express; 2015 Nov; 6(11):4557-66. PubMed ID: 26601018
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Live feedback and 3D photoacoustic remote sensing.
    Abbasi S; Bell K; Ecclestone B; Haji Reza P
    Quant Imaging Med Surg; 2021 Mar; 11(3):1033-1045. PubMed ID: 33654675
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quickly Alternating Green and Red Laser Source for Real-time Multispectral Photoacoustic Microscopy.
    Park SM; Kim DY; Cho SW; Kim BM; Lee TG; Kim CS; Lee SW
    Photoacoustics; 2020 Dec; 20():100204. PubMed ID: 33014706
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ablation of porcine ligamentum flavum with Ho:YAG, q-switched Ho:YAG, and quadrupled Nd:YAG lasers.
    Johnson MR; Codd PJ; Hill WM; Boettcher T
    Lasers Surg Med; 2015 Dec; 47(10):839-51. PubMed ID: 26415136
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cost-efficient laser-diode-induced optical-resolution photoacoustic microscopy for two-dimensional/three-dimensional biomedical imaging.
    Zeng L; Liu G; Yang D; Ji X
    J Biomed Opt; 2014; 19(7):076017. PubMed ID: 25057961
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deep tissue photoacoustic computed tomography with a fast and compact laser system.
    Wang D; Wang Y; Wang W; Luo D; Chitgupi U; Geng J; Zhou Y; Wang L; Lovell JF; Xia J
    Biomed Opt Express; 2017 Jan; 8(1):112-123. PubMed ID: 28101405
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fiber laser technologies for photoacoustic microscopy.
    Jin L; Liang Y
    Vis Comput Ind Biomed Art; 2021 Apr; 4(1):11. PubMed ID: 33928461
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study.
    Wei CW; Nguyen TM; Xia J; Arnal B; Wong EY; Pelivanov IM; O'Donnell M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Feb; 62(2):319-28. PubMed ID: 25643081
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.