253 related articles for article (PubMed ID: 26978137)
1. Biomechanical Contribution of Tension-Reducing Rotator Cuff Sutures in 3-Part Proximal Humerus Fractures.
Arvesen JE; Gill SW; Sinatra PM; Eng M; Bledsoe G; Kaar SG
J Orthop Trauma; 2016 Aug; 30(8):e262-6. PubMed ID: 26978137
[TBL] [Abstract][Full Text] [Related]
2. No Contribution of Tension-Reducing Rotator Cuff Sutures on Locking Plate Fixation in a 2-Part Proximal Humerus Fracture Model.
Sinatra PM; Jernick ML; Bledsoe G; Kaar SG
J Orthop Trauma; 2014 Aug; 28(8):458-63. PubMed ID: 24375272
[TBL] [Abstract][Full Text] [Related]
3. The results of tension band rotator cuff suture fixation of locked plating of displaced proximal humerus fractures.
Shukla DR; McAnany S; Pean C; Overley S; Lovy A; Parsons BO
Injury; 2017 Feb; 48(2):474-480. PubMed ID: 28063677
[TBL] [Abstract][Full Text] [Related]
4. Surgical Treatment of Displaced Greater Tuberosity Fractures of the Humerus.
Rouleau DM; Mutch J; Laflamme GY
J Am Acad Orthop Surg; 2016 Jan; 24(1):46-56. PubMed ID: 26700632
[TBL] [Abstract][Full Text] [Related]
5. Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.
Gaudelli C; Ménard J; Mutch J; Laflamme GY; Petit Y; Rouleau DM
Clin Biomech (Bristol, Avon); 2014 Nov; 29(9):1003-8. PubMed ID: 25246375
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of Rotator Cuff Augmentation of Proximal Humerus Fracture Fixation.
El-Gazzar Y; Davis E; Beals TR; Flandry F
J Surg Orthop Adv; 2022; 31(2):119-122. PubMed ID: 35820099
[TBL] [Abstract][Full Text] [Related]
7. Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens.
Voigt C; Hurschler C; Rechi L; Vosshenrich R; Lill H
Acta Orthop; 2009 Aug; 80(4):465-71. PubMed ID: 19562564
[TBL] [Abstract][Full Text] [Related]
8. Arthroscopic Fixation of Tibial Eminence Fractures: A Biomechanical Comparative Study of Screw, Suture, and Suture Anchor.
Li J; Yu Y; Liu C; Su X; Liao W; Li Z
Arthroscopy; 2018 May; 34(5):1608-1616. PubMed ID: 29397286
[TBL] [Abstract][Full Text] [Related]
9. Surgical management of isolated greater tuberosity fractures of the proximal humerus.
DeBottis D; Anavian J; Green A
Orthop Clin North Am; 2014 Apr; 45(2):207-18. PubMed ID: 24684914
[TBL] [Abstract][Full Text] [Related]
10. Relationship of cortical thickness of the proximal humerus and pullout strength of a locked plate and screw construct.
Wallace MJ; Bledsoe G; Moed BR; Israel HA; Kaar SG
J Orthop Trauma; 2012 Apr; 26(4):222-5. PubMed ID: 22207205
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model.
Walsh S; Reindl R; Harvey E; Berry G; Beckman L; Steffen T
Clin Biomech (Bristol, Avon); 2006 Dec; 21(10):1027-31. PubMed ID: 16919375
[TBL] [Abstract][Full Text] [Related]
12. A Transosseous Suture as an Alternative to Suture Anchor on Anterior-Avulsion Greater Tuberosity Fragment Fixation in Neer Three-Part Proximal Humeral Fracture: A Biomechanical Study.
Ju J; Ma M; Ding Z; Zhang Y; Fu Z; Chen J
Orthop Surg; 2023 Aug; 15(8):2132-2137. PubMed ID: 36331129
[TBL] [Abstract][Full Text] [Related]
13. A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures.
Walker R; Castaneda P; Putnam JG; Schemitsch EH; McKee MD
J Orthop Trauma; 2020 Jul; 34(7):e233-e238. PubMed ID: 31977668
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.
Röderer G; Scola A; Schmölz W; Gebhard F; Windolf M; Hofmann-Fliri L
Injury; 2013 Oct; 44(10):1327-32. PubMed ID: 23769470
[TBL] [Abstract][Full Text] [Related]
15. Additional cuff suture provides mechanical advantage for fixation of split-type greater tuberosity fracture of humerus.
Pisitwattanaporn P; Saengpetch N; Thamyongkit S; Wanitchanont T; Sa-Ngasoongsong P; Aroonjarattham P
Injury; 2022 Dec; 53(12):4033-4037. PubMed ID: 36424688
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical evaluation of two intramedullary nailing techniques with different locking options in a three-part fracture proximal humerus model.
Rothstock S; Plecko M; Kloub M; Schiuma D; Windolf M; Gueorguiev B
Clin Biomech (Bristol, Avon); 2012 Aug; 27(7):686-91. PubMed ID: 22465242
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of BioCorkscrew and Bioknotless RC suture anchor rotator cuff repair fixation: an in vitro biomechanical study.
Ammon JT; Nyland J; Chang HC; Burden R; Caborn DN
Knee Surg Sports Traumatol Arthrosc; 2007 Nov; 15(11):1375-81. PubMed ID: 17437085
[TBL] [Abstract][Full Text] [Related]
18. Simultaneous repair of chronic full-thickness rotator cuff tears during fixation of proximal humerus fractures and clinical results.
Aksu N; Aslan O; Kara AN; Işiklar ZU
Acta Orthop Traumatol Turc; 2010; 44(3):173-9. PubMed ID: 21088456
[TBL] [Abstract][Full Text] [Related]
19. A novel suture anchor constructed of cortical bone for rotator cuff repair: a biomechanical study on sheep humerus specimens.
Guo Q; Li C; Qi W; Li H; Lu X; Shen X; Qu F; Liu Y
Int Orthop; 2016 Sep; 40(9):1913-8. PubMed ID: 27055449
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.
Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):735-41. PubMed ID: 24997810
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]