These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 26978706)

  • 1. Exertional Angina Due To Fused Aortic Bioprosthesis During Left Ventricular Assist Device Support: Two Cases and Review of the Literature.
    Bonios MJ; Selzman CH; Gilbert EM; McKellar SH; Koliopoulou A; Strege JL; Nativi JN; Fang JC; Stehlik J; Drakos SG
    ASAIO J; 2017; 63(1):e6-e9. PubMed ID: 26978706
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A modified Park's stitch to correct aortic insufficiency for bioprosthetic valve at time of left ventricular assist device implant: a case report.
    Kazui T; Sydow N; Friedman M; Kim S; Lick S; Khalpey Z
    J Cardiothorac Surg; 2016 Nov; 11(1):161. PubMed ID: 27899134
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Management of aortic insufficiency with continuous flow left ventricular assist devices: bioprosthetic valve replacement.
    Feldman CM; Silver MA; Sobieski MA; Slaughter MS
    J Heart Lung Transplant; 2006 Dec; 25(12):1410-2. PubMed ID: 17178333
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is a Bioprosthetic Valve in the Aortic Position Desirable with a Continuous Flow LVAD?
    Doi A; Marasco SF; McGiffin DC
    J Card Surg; 2015 May; 30(5):466-8. PubMed ID: 25807875
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transfemoral transcatheter aortic valve replacement with a self-expanding valve for severe aortic regurgitation in a patient with left ventricular assist device.
    Rene AG; Desai N; Wald J; Rame JE; Frogel JK; Anwaruddin S
    J Card Surg; 2017 Nov; 32(11):741-745. PubMed ID: 29178215
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous aortic valve replacement in left ventricular assist device recipients: single-center experience.
    Dranishnikov N; Stepanenko A; Potapov EV; Dandel M; Siniawski H; Mladenow A; Hübler M; Grauhan O; Weng Y; Krabatsch T; Hetzer R; Kukucka M
    Int J Artif Organs; 2012 Jul; 35(7):489-94. PubMed ID: 22661109
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Emergency transcatheter aortic valve implantation in patients with severe aortic regurgitation and a left ventricle assist device: A case report and systematic review.
    van der Werf HW; Schurer RA; Vonck TE; Poelman JE; Klungel AA; Cernak V; van den Heuvel AF; van der Harst P
    Eur Heart J Acute Cardiovasc Care; 2017 Dec; 6(8):719-727. PubMed ID: 27245700
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgical correction of aortic valve insufficiency after left ventricular assist device implantation.
    Atkins BZ; Hashmi ZA; Ganapathi AM; Harrison JK; Hughes GC; Rogers JG; Milano CA
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1247-52. PubMed ID: 23870154
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Sudden Chest Pain due to Early Bioprosthetic Valve Dysfunction:Report of a Case].
    Yamakawa M; Yokoyama Y; Yamada M; Ashida S; Hasegawa H; Yokote J
    Kyobu Geka; 2024 Mar; 77(3):206-209. PubMed ID: 38465492
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy and durability of central oversewing for treatment of aortic insufficiency in patients with continuous-flow left ventricular assist devices.
    Schechter MA; Joseph JT; Krishnamoorthy A; Finet JE; Ganapathi AM; Lodge AJ; Milano CA; Patel CB
    J Heart Lung Transplant; 2014 Sep; 33(9):937-42. PubMed ID: 24997496
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acquired aortic cusp fusion after chronic left ventricular assist device support.
    Banchs JE; Dawn B; Abdel-Latif A; Qureshi A; Agrawal N; Bouvette M; Stoddard MF
    J Am Soc Echocardiogr; 2006 Nov; 19(11):1401.e1-3. PubMed ID: 17098144
    [TBL] [Abstract][Full Text] [Related]  

  • 12. LVAD with concomitant rapid deployment valve implantation - a case report.
    Holloway DD; Jones LC; Howell SJ; Rich JD; Pham DT
    J Cardiothorac Surg; 2019 Jul; 14(1):126. PubMed ID: 31262339
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transfemoral aortic valve replacement for severe aortic valve regurgitation in a patient with a pulsatile-flow biventricular assist device.
    Gomes B; Bekeredjian R; Leuschner F; Ehlermann P; Schmack B; Ruhparwar A; Raake PW; Katus HA; Kreusser MM
    ESC Heart Fail; 2019 Feb; 6(1):217-221. PubMed ID: 30479049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of aortic valve opening in patients with aortic insufficiency after left ventricular assist device implantation.
    da Rocha E Silva JG; Meyer AL; Eifert S; Garbade J; Mohr FW; Strueber M
    Eur J Cardiothorac Surg; 2016 Mar; 49(3):784-7. PubMed ID: 26084757
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First report of a simultaneous transcatheter mitral valve-in-valve and aortic valve replacement in a left ventricular assist device patient.
    Meduri C; Kauten J; Vannan M; Rajagopal V
    Catheter Cardiovasc Interv; 2017 Sep; 90(3):526-529. PubMed ID: 28295972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ventricular Septal Defect from Aortic Regurgitation Jet Lesion in Aortic Valve Infective Endocarditis.
    Darabant S; Oberton SB; Roldan LP; Roldan CA
    J Heart Valve Dis; 2016 Mar; 25(2):150-152. PubMed ID: 27989057
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Complete fusion of a percutaneous aortic valve placed after ventricular assist device.
    Derryberry SL; Williams RD; Fredi JL; Ball SK
    Interact Cardiovasc Thorac Surg; 2017 Aug; 25(2):329-330. PubMed ID: 28475802
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses--valve-in-valve technique.
    Gotzmann M; Mügge A; Bojara W
    Catheter Cardiovasc Interv; 2010 Dec; 76(7):1000-6. PubMed ID: 20824744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Abnormal distortion of aortic corevalve bioprosthesis with suicide left ventricle, aortic insufficiency, and severe mitral regurgitation during transcatheter aortic valve replacement.
    Leya F; Tuchek JM; Coats W
    Catheter Cardiovasc Interv; 2016 Dec; 88(7):1181-1187. PubMed ID: 26945836
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A case in which biventricular assist device support was required after aortic valve replacement with a bioprosthetic valve.
    Koizumi K; Yozu R; Shin H; Tsutsumi K; Enoki C; Iino Y; Matayoshi T; Morita M
    J Artif Organs; 2003; 6(3):218-21. PubMed ID: 14598107
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.