BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 26982341)

  • 1. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.
    Liu S; Xia Z; Liu J; Xu J; Ren H; Lu T; Yang X
    PLoS One; 2016; 11(3):e0149482. PubMed ID: 26982341
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours.
    Xu J; Jia ZZ; Song ZJ; Yang XD; Chen K; Liang P
    Int J Med Robot; 2010 Sep; 6(3):256-68. PubMed ID: 20564429
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automatic entry point planning for robotic post-mortem CT-based needle placement.
    Ebert LC; Fürst M; Ptacek W; Ruder TD; Gascho D; Schweitzer W; Thali MJ; Flach PM
    Forensic Sci Med Pathol; 2016 Sep; 12(3):336-42. PubMed ID: 27421263
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Overlapping radiofrequency ablation planning and robot-assisted needle insertion for large liver tumors.
    Liu P; Qin J; Duan B; Wang Q; Tan X; Zhao B; Jonnathan PL; Chui CK; Heng PA
    Int J Med Robot; 2019 Feb; 15(1):e1952. PubMed ID: 30117266
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automatic planning of needle placement for robot-assisted percutaneous procedures.
    Belbachir E; Golkar E; Bayle B; Essert C
    Int J Comput Assist Radiol Surg; 2018 Sep; 13(9):1429-1438. PubMed ID: 29671199
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computer-assisted trajectory planning for percutaneous needle insertions.
    Seitel A; Engel M; Sommer CM; Radeleff BA; Essert-Villard C; Baegert C; Fangerau M; Fritzsche KH; Yung K; Meinzer HP; Maier-Hein L
    Med Phys; 2011 Jun; 38(6):3246-59. PubMed ID: 21815399
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Accuracy analysis of robotic assistant needle placement for trigeminal gasserian ganglion].
    Zhu JH; Wang J; Liu XJ; Guo CB
    Beijing Da Xue Xue Bao Yi Xue Ban; 2019 Oct; 51(5):973-976. PubMed ID: 31624409
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hand gesture guided robot-assisted surgery based on a direct augmented reality interface.
    Wen R; Tay WL; Nguyen BP; Chng CB; Chui CK
    Comput Methods Programs Biomed; 2014 Sep; 116(2):68-80. PubMed ID: 24438993
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Robotic assistance for percutaneous needle insertion in the kidney: preclinical proof on a swine animal model.
    de Baere T; Roux C; Noel G; Delpla A; Deschamps F; Varin E; Tselikas L
    Eur Radiol Exp; 2022 Mar; 6(1):13. PubMed ID: 35257224
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental analysis of robot-assisted needle insertion into porcine liver.
    Wang W; Shi Y; Goldenberg AA; Yuan X; Zhang P; He L; Zou Y
    Biomed Mater Eng; 2015; 26 Suppl 1():S375-80. PubMed ID: 26406026
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automatic and accurate needle detection in 2D ultrasound during robot-assisted needle insertion process.
    Chen S; Lin Y; Li Z; Wang F; Cao Q
    Int J Comput Assist Radiol Surg; 2022 Feb; 17(2):295-303. PubMed ID: 34677747
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Phantom and Animal Study of a Robot-Assisted, CT-Guided Targeting System using Image-Only Navigation for Stereotactic Needle Insertion without Positional Sensors.
    Fong KY; Tan ASM; Bin Sulaiman MS; Leong SH; Ng KW; Too CW
    J Vasc Interv Radiol; 2022 Nov; 33(11):1416-1423.e4. PubMed ID: 35970505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Zerobot®: A Remote-controlled Robot for Needle Insertion in CT-guided Interventional Radiology Developed at Okayama University.
    Hiraki T; Kamegawa T; Matsuno T; Komaki T; Sakurai J; Kanazawa S
    Acta Med Okayama; 2018 Dec; 72(6):539-546. PubMed ID: 30573907
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Automatic Robotic Puncture System for Accurate Liver Cancer Ablation Based on Optical Surgical Navigation].
    Hou J; Yang R; Lin Q; Zhang Z; Xie Y; Huang M
    Zhongguo Yi Liao Qi Xie Za Zhi; 2018 Jan; 42(1):27-30. PubMed ID: 29862741
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of the needle insertion robot for percutaneous vertebroplasty.
    Onogi S; Morimoto K; Sakuma I; Nakajima Y; Koyama T; Sugano N; Tamura Y; Yonenobu S; Momoi Y
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 2):105-13. PubMed ID: 16685949
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.
    Gravett M; Cepek J; Fenster A
    Med Phys; 2017 Nov; 44(11):5544-5555. PubMed ID: 28849592
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Robotic Insertion of Various Ablation Needles Under Computed Tomography Guidance: Accuracy in Animal Experiments.
    Hiraki T; Matsuno T; Kamegawa T; Komaki T; Sakurai J; Matsuura R; Yamaguchi T; Sasaki T; Iguchi T; Matsui Y; Gobara H; Kanazawa S
    Eur J Radiol; 2018 Aug; 105():162-167. PubMed ID: 30017274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.
    Li P; Yang Z; Jiang S
    Med Biol Eng Comput; 2018 Jun; 56(6):931-949. PubMed ID: 29679255
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automatic Robotic Steering of Flexible Needles from 3D Ultrasound Images in Phantoms and Ex Vivo Biological Tissue.
    Mignon P; Poignet P; Troccaz J
    Ann Biomed Eng; 2018 Sep; 46(9):1385-1396. PubMed ID: 29845413
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Needle release mechanism enabling multiple insertions with an ultrasound-guided prostate brachytherapy robot.
    Shuyang Chen ; Gonenc B; Meng Li ; Song DY; Burdette EC; Iordachita I; Kazanzides P
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():4339-4342. PubMed ID: 29060857
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.