21. Improved glottic exposure with the Video Macintosh Laryngoscope in adult emergency department tracheal intubations. Brown CA; Bair AE; Pallin DJ; Laurin EG; Walls RM; Ann Emerg Med; 2010 Aug; 56(2):83-8. PubMed ID: 20202720 [TBL] [Abstract][Full Text] [Related]
22. Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. Aziz MF; Dillman D; Fu R; Brambrink AM Anesthesiology; 2012 Mar; 116(3):629-36. PubMed ID: 22261795 [TBL] [Abstract][Full Text] [Related]
23. Randomized controlled trial comparing the McGrath MAC video laryngoscope with the King Vision video laryngoscope in adult patients. Alvis BD; Hester D; Watson D; Higgins M; St Jacques P Minerva Anestesiol; 2016 Jan; 82(1):30-5. PubMed ID: 25881731 [TBL] [Abstract][Full Text] [Related]
24. Use of the GlideScope Ranger Video Laryngoscope for Emergency Intubation in the Prehospital Setting: A Randomized Control Trial. Trimmel H; Kreutziger J; Fitzka R; Szüts S; Derdak C; Koch E; Erwied B; Voelckel WG Crit Care Med; 2016 Jul; 44(7):e470-6. PubMed ID: 27002277 [TBL] [Abstract][Full Text] [Related]
25. Using a Bougie With C-MAC Video Laryngoscopy Did Not Improve First-Attempt Intubation Success Rates in Critical Care Air Transport. Waldron O; Sena R; Boehmer S; Flamm A Air Med J; 2023; 42(6):445-449. PubMed ID: 37996180 [TBL] [Abstract][Full Text] [Related]
26. A Comparison of Paramedic First Pass Endotracheal Intubation Success Rate of the VividTrac VT-A 100, GlideScope Ranger, and Direct Laryngoscopy Under Simulated Prehospital Cervical Spinal Immobilization Conditions in a Cadaveric Model. Hodnick R; Zitek T; Galster K; Johnson S; Bledsoe B; Ebbs D Prehosp Disaster Med; 2017 Dec; 32(6):621-624. PubMed ID: 28807073 [TBL] [Abstract][Full Text] [Related]
27. Comparison of Endotracheal Intubation Skills With Video Laryngoscopy and Direct Laryngoscopy in Providing Airway Patency in a Moving Ambulance. Gok PG; Ozakin E; Acar N; Karakilic E; Kaya FB; Tekin N; Yazlamaz NO J Emerg Med; 2021 Jun; 60(6):752-759. PubMed ID: 33518375 [TBL] [Abstract][Full Text] [Related]
28. Preliminary Experience With Inertial Movement Technology to Characterize Endotracheal Intubation Kinematics. Carlson JN; Cho S; Ohu IPN; Griffin RE; Ko HS; Lim C; Wang HE Simul Healthc; 2020 Jun; 15(3):160-166. PubMed ID: 32398415 [TBL] [Abstract][Full Text] [Related]
29. Video-laryngoscopy versus direct laryngoscopy in critically ill patients: a pilot randomized trial. Griesdale DE; Chau A; Isac G; Ayas N; Foster D; Irwin C; Choi P; Can J Anaesth; 2012 Nov; 59(11):1032-9. PubMed ID: 22932944 [TBL] [Abstract][Full Text] [Related]
30. The efficacy of the Storz Miller 1 video laryngoscope in a simulated infant difficult intubation. Fiadjoe JE; Stricker PA; Hackell RS; Salam A; Gurnaney H; Rehman MA; Litman RS Anesth Analg; 2009 Jun; 108(6):1783-6. PubMed ID: 19448202 [TBL] [Abstract][Full Text] [Related]
31. A comparison of the Truview PCD and the GlideScope Cobalt AVL video-laryngoscopes to the Miller blade for successfully intubating manikins simulating normal and difficult pediatric airways. Hippard HK; Kalyani G; Olutoye OA; Mann DG; Watcha MF Paediatr Anaesth; 2016 Jun; 26(6):613-20. PubMed ID: 27083381 [TBL] [Abstract][Full Text] [Related]
32. A deliberately restricted laryngeal view with the GlideScope® video laryngoscope is associated with faster and easier tracheal intubation when compared with a full glottic view: a randomized clinical trial. Gu Y; Robert J; Kovacs G; Milne AD; Morris I; Hung O; MacQuarrie K; Mackinnon S; Adam Law J Can J Anaesth; 2016 Aug; 63(8):928-37. PubMed ID: 27090535 [TBL] [Abstract][Full Text] [Related]
33. The Association of Laryngeal Position on Videolaryngoscopy and Time Taken to Intubate Using Spatial Point Pattern Analysis of Prospectively Collected Quality Assurance Data. Miller MR; Gemal H; Ware S; Hayes-Bradley C Anesth Analg; 2022 Jun; 134(6):1288-1296. PubMed ID: 35020681 [TBL] [Abstract][Full Text] [Related]
34. Comparison of the C-MAC video laryngoscope to a flexible fiberoptic scope for intubation with cervical spine immobilization. Yumul R; Elvir-Lazo OL; White PF; Durra O; Ternian A; Tamman R; Naruse R; Ebba H; Yusufali T; Wong R; Hernandez Conte A; Farnad S; Pham C; Wender RH J Clin Anesth; 2016 Jun; 31():46-52. PubMed ID: 27185677 [TBL] [Abstract][Full Text] [Related]
35. Biomechanical evaluation of the phases during simulated endotracheal intubation (ETI): pilot study on the effect of different laryngoscopes. Bartolomeo L; Noh Y; Kasuya Y; Nagai M; Zecca M; Sessa S; Cosentino S; Saito K; Lin Z; Ishii H; Takanishi A Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4887-90. PubMed ID: 24110830 [TBL] [Abstract][Full Text] [Related]
36. Comparing the novel GlideScope Groove videolaryngoscope with conventional videolaryngoscopy: a randomized mannequin study of novice providers. Tung A; Griesdale DE J Clin Anesth; 2013 Dec; 25(8):644-50. PubMed ID: 24095892 [TBL] [Abstract][Full Text] [Related]
37. First clinical evaluation of the C-MAC D-Blade videolaryngoscope during routine and difficult intubation. Cavus E; Neumann T; Doerges V; Moeller T; Scharf E; Wagner K; Bein B; Serocki G Anesth Analg; 2011 Feb; 112(2):382-5. PubMed ID: 21156978 [TBL] [Abstract][Full Text] [Related]
38. Comparison of the TruView PCD video laryngoscope and macintosh laryngoscope for pediatric tracheal intubation by novice paramedics: a randomized crossover simulation trial. Szarpak Ł; Czyżewski Ł; Kurowski A; Truszewski Z Eur J Pediatr; 2015 Oct; 174(10):1325-32. PubMed ID: 25894914 [TBL] [Abstract][Full Text] [Related]
39. Optimization of glottic exposure during intubation of a patient lying supine on the ground. Adnet F; Lapostolle F; Borron SW; Hennequin B; Leclercq G; Fleury M Am J Emerg Med; 1997 Oct; 15(6):555-7. PubMed ID: 9337359 [TBL] [Abstract][Full Text] [Related]
40. Comparison of the GlideScope Cobalt® and Storz DCI® Video Laryngoscopes in Children Younger Than 2 Years of Age During Manual In-Line Stabilization: A Randomized Trainee Evaluation Study. Vadi MG; Roddy KJ; Ghazal EA; Um M; Neiheisel AJ; Applegate RL Pediatr Emerg Care; 2017 Jul; 33(7):467-473. PubMed ID: 26785097 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]