244 related articles for article (PubMed ID: 27002017)
1. Use of the frozen elephant trunk technique in complicated chronic dissection with porcelain aorta and visceral arteries originating from different lumens.
Zembala MO; Irimie V; Urbanski PP
Interact Cardiovasc Thorac Surg; 2016 Apr; 22(4):504-6. PubMed ID: 27002017
[TBL] [Abstract][Full Text] [Related]
2. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.
Hirano K; Tokui T; Nakamura B; Inoue R; Inagaki M; Maze Y; Kato N
Vasc Endovascular Surg; 2018 Jan; 52(1):80-85. PubMed ID: 29121846
[TBL] [Abstract][Full Text] [Related]
3. Repair of Chronic Aneurysmal Aortic Dissection Using a Stent Graft and an Amplatzer
Kanaoka Y; Ohki T; Ozawa H
Ann Vasc Surg; 2017 Feb; 39():288.e5-288.e12. PubMed ID: 27671450
[TBL] [Abstract][Full Text] [Related]
4. Reversed Frozen Elephant Trunk Technique to Treat a Type II Thoracoabdominal Aortic Aneurysm.
Debus ES; Kölbel T; Wipper S; Diener H; Reiter B; Detter C; Tsilimparis N
J Endovasc Ther; 2017 Apr; 24(2):277-280. PubMed ID: 28112018
[TBL] [Abstract][Full Text] [Related]
5. Experimental evaluation of homemade distal stent graft fenestration for thoracic endovascular aortic repair of type A dissection by a transapical approach.
Gandet T; Seghrouchni A; Ozdemir BA; Captier G; Demaria R; Alric P; Albat B; Canaud L
J Vasc Surg; 2018 Oct; 68(4):1217-1224. PubMed ID: 29680298
[TBL] [Abstract][Full Text] [Related]
6. Frozen elephant trunk repair for descending thoracic aortic dissection in a man with a hostile left pleural cavity.
Kent WD; Manjunath A; Malaisrie SC
Tex Heart Inst J; 2014 Jun; 41(3):341-3. PubMed ID: 24955060
[TBL] [Abstract][Full Text] [Related]
7. Endovascular aortic repair as second-stage surgery after hybrid open arch repair by the frozen elephant trunk technique for extended thoracic aneurysm.
Uchida N; Kodama H; Katayama K; Takasaki T; Katayama A; Takahashi S; Sueda T
Ann Thorac Cardiovasc Surg; 2013; 19(3):257-61. PubMed ID: 22971718
[TBL] [Abstract][Full Text] [Related]
8. Staged treatment of mega aortic syndrome using the frozen elephant trunk and hybrid thoracoabdominal repair.
Gkremoutis A; Zierer A; Schmitz-Rixen T; El-Sayed Ahmad A; Kaiser E; Keese M; Schmandra T
J Thorac Cardiovasc Surg; 2017 Dec; 154(6):1842-1849. PubMed ID: 28734626
[TBL] [Abstract][Full Text] [Related]
9. Candy-Plug Technique Using an Excluder Aortic Extender for Distal Occlusion of a Large False Lumen Aneurysm in Chronic Aortic Dissection.
Ogawa Y; Nishimaki H; Chiba K; Murakami K; Sakurai Y; Fujiwara K; Miyairi T; Nakajima Y
J Endovasc Ther; 2016 Jun; 23(3):483-6. PubMed ID: 27009975
[TBL] [Abstract][Full Text] [Related]
10. Acute Type A Aortic Dissection Treated Using a Tubular Stent-Graft in the Ascending Aorta and a Multibranched Stent-Graft in the Aortic Arch.
Kölbel T; Detter C; Carpenter SW; Rohlffs F; von Kodolitsch Y; Wipper S; Reichenspurner H; Debus ES; Tsilimparis N
J Endovasc Ther; 2017 Feb; 24(1):75-80. PubMed ID: 27881689
[TBL] [Abstract][Full Text] [Related]
11. Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection.
Huang CY; Weng SH; Weng CF; Chen WY; Chen IM; Hsu CP; Shih CC
J Thorac Cardiovasc Surg; 2013 Sep; 146(3):623-30. PubMed ID: 23040193
[TBL] [Abstract][Full Text] [Related]
12. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.
Sobocinski J; Lombardi JV; Dias NV; Berger L; Zhou Q; Jia F; Resch T; Haulon S
J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523
[TBL] [Abstract][Full Text] [Related]
13. Stented elephant trunk procedure with left subclavian artery transposition for acute type B dissection with distal arch involvement.
Zhu JM; Qi RD; Chen L; Liu W; Li CN; Fan ZM; Sun LZ
J Thorac Cardiovasc Surg; 2015 Nov; 150(5):1160-5. PubMed ID: 26344688
[TBL] [Abstract][Full Text] [Related]
14. One-stage total thoracic aortic repair for mega-aorta using frozen elephant trunk technique.
Uchida N; Katayama A; Kuraoka M; Sueda T
Interact Cardiovasc Thorac Surg; 2011 Oct; 13(4):419-20. PubMed ID: 21724660
[TBL] [Abstract][Full Text] [Related]
15. Frozen elephant trunk procedure in a dextropositioned arch and descending aorta.
Easo J; Hölzl P; Dikov V; Chavan A; Dapunt O
J Endovasc Ther; 2010 Dec; 17(6):751-4. PubMed ID: 21142485
[TBL] [Abstract][Full Text] [Related]
16. Association between Aortic Remodeling and Stent Graft-Induced New Entry in Extensive Residual Type A Dissecting Aortic Aneurysm after Hybrid Arch Repair.
Huang CY; Chen CW; Chen PL; Chen WY; Chen IM; Hsu CP; Shih CC
Ann Vasc Surg; 2016 Feb; 31():60-9. PubMed ID: 26620378
[TBL] [Abstract][Full Text] [Related]
17. Hybrid thoracoabdominal aneurysm repair with simultaneous antegrade visceral revascularization and supra-aortic debranching from the ascending aorta.
Torsello G; Can A; Umscheid T; Tessarek J
J Endovasc Ther; 2007 Jun; 14(3):342-6. PubMed ID: 17723013
[TBL] [Abstract][Full Text] [Related]
18. Endovascular aortic repair of a chronic ascending and arch aortic aneurysm.
Gandet T; Alric P; Bommart S; Canaud L
J Thorac Cardiovasc Surg; 2018 Mar; 155(3):e79-e83. PubMed ID: 28987735
[No Abstract] [Full Text] [Related]
19. Total arch replacement and frozen elephant trunk for acute type A aortic dissection.
Iino K; Takago S; Saito N; Ueda H; Yamamoto Y; Kato H; Kimura K; Takemura H
J Thorac Cardiovasc Surg; 2022 Nov; 164(5):1400-1409.e3. PubMed ID: 33341270
[TBL] [Abstract][Full Text] [Related]
20. Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection.
Zhao Y; Yin H; Chen Y; Wang M; Zheng L; Li Z; Chang G
J Vasc Surg; 2018 Jan; 67(1):93-103. PubMed ID: 28711399
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]