145 related articles for article (PubMed ID: 27002900)
1. Photon source term after single collision in targets of silicon, copper and lead for 50-500 keV X-ray beams.
Nariyama N
J Xray Sci Technol; 2016 Mar; 24(3):343-51. PubMed ID: 27002900
[TBL] [Abstract][Full Text] [Related]
2. A new concept of pencil beam dose calculation for 40-200 keV photons using analytical dose kernels.
Bartzsch S; Oelfke U
Med Phys; 2013 Nov; 40(11):111714. PubMed ID: 24320422
[TBL] [Abstract][Full Text] [Related]
3. Application of the diagnostic radiological index of protection to protective garments.
Pasciak AS; Jones AK; Wagner LK
Med Phys; 2015 Feb; 42(2):653-662. PubMed ID: 28102605
[TBL] [Abstract][Full Text] [Related]
4. Radiation induced current in the RF coils of integrated linac-MR systems: the effect of buildup and magnetic field.
Burke B; Ghila A; Fallone BG; Rathee S
Med Phys; 2012 Aug; 39(8):5004-14. PubMed ID: 22894426
[TBL] [Abstract][Full Text] [Related]
5. Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities.
Kharrati H; Agrebi A; Karaoui MK
Med Phys; 2007 Apr; 34(4):1398-404. PubMed ID: 17500471
[TBL] [Abstract][Full Text] [Related]
6. Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam.
Ding GX
Med Phys; 2002 Nov; 29(11):2459-63. PubMed ID: 12462709
[TBL] [Abstract][Full Text] [Related]
7. The influence of self-absorption on PET and PET/CT shielding requirements.
Elschot M; de Wit TC; de Jong HW
Med Phys; 2010 Jun; 37(6):2999-3007. PubMed ID: 20632612
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo simulation of diagnostic x-ray scatter.
Papin PJ; Rielly PS
Med Phys; 1988; 15(6):909-14. PubMed ID: 3237150
[TBL] [Abstract][Full Text] [Related]
9. The spectrum and angular distribution of x rays scattered from a water phantom.
Cheng CW; Taylor KW; Holloway AF
Med Phys; 1995 Aug; 22(8):1235-45. PubMed ID: 7476709
[TBL] [Abstract][Full Text] [Related]
10. Fundamental x-ray interaction limits in diagnostic imaging detectors: spatial resolution.
Hajdok G; Battista JJ; Cunningham IA
Med Phys; 2008 Jul; 35(7):3180-93. PubMed ID: 18697543
[TBL] [Abstract][Full Text] [Related]
11. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
[TBL] [Abstract][Full Text] [Related]
12. An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.
Kim J; Hill R; Claridge Mackonis E; Kuncic Z
Phys Med Biol; 2010 Feb; 55(3):783-97. PubMed ID: 20071763
[TBL] [Abstract][Full Text] [Related]
13. Head scatter off-axis for megavoltage x rays.
Zhu TC; Bjärngard BE
Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo simulation of photon buildup factors for shielding materials in radiotherapy x-ray facilities.
Karoui MK; Kharrati H
Med Phys; 2013 Jul; 40(7):073901. PubMed ID: 23822458
[TBL] [Abstract][Full Text] [Related]
15. A model for the energy and angular distribution of x rays emitted from an x-ray tube. Part II. Validation of x-ray spectra from 20 to 300 kV.
Omar A; Andreo P; Poludniowski G
Med Phys; 2020 Sep; 47(9):4005-4019. PubMed ID: 32593216
[TBL] [Abstract][Full Text] [Related]
16. Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques.
Safigholi H; Faghihi R; Jashni SK; Meigooni AS
Med Phys; 2012 Apr; 39(4):1971-9. PubMed ID: 22482618
[TBL] [Abstract][Full Text] [Related]
17. The characterization and transmission of scattered radiation resulting from x-ray beams filtered with zero to 0.99 mm copper.
Sutton DG; Martin CJ; Peet D; Williams JR
J Radiol Prot; 2012 Jun; 32(2):117-29. PubMed ID: 22555158
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo calculations of kQ, the beam quality conversion factor.
Muir BR; Rogers DW
Med Phys; 2010 Nov; 37(11):5939-50. PubMed ID: 21158307
[TBL] [Abstract][Full Text] [Related]
19. Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data.
Zourari K; Peppa V; Ballester F; Siebert FA; Papagiannis P
Med Phys; 2014 Apr; 41(4):043901. PubMed ID: 24694161
[TBL] [Abstract][Full Text] [Related]
20. Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events.
Liaparinos PF; Kandarakis IS
Med Phys; 2011 Jul; 38(7):4440-50. PubMed ID: 21859045
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]