260 related articles for article (PubMed ID: 27004291)
1. The Use of Photofunctionalized Implants for Low or Extremely Low Primary Stability Cases.
Kitajima H; Ogawa T
Int J Oral Maxillofac Implants; 2016; 31(2):439-47. PubMed ID: 27004291
[TBL] [Abstract][Full Text] [Related]
2. Implant Stability Development of Photofunctionalized Implants Placed in Regular and Complex Cases: A Case-Control Study.
Hirota M; Ozawa T; Iwai T; Ogawa T; Tohnai I
Int J Oral Maxillofac Implants; 2016; 31(3):676-86. PubMed ID: 27183088
[TBL] [Abstract][Full Text] [Related]
3. Photofunctionalized dental implants: a case series in compromised bone.
Funato A; Ogawa T
Int J Oral Maxillofac Implants; 2013; 28(6):1589-601. PubMed ID: 24278928
[TBL] [Abstract][Full Text] [Related]
4. Success rate, healing time, and implant stability of photofunctionalized dental implants.
Funato A; Yamada M; Ogawa T
Int J Oral Maxillofac Implants; 2013; 28(5):1261-71. PubMed ID: 24066316
[TBL] [Abstract][Full Text] [Related]
5. Implant stability change and osseointegration speed of immediately loaded photofunctionalized implants.
Suzuki S; Kobayashi H; Ogawa T
Implant Dent; 2013 Oct; 22(5):481-90. PubMed ID: 24021973
[TBL] [Abstract][Full Text] [Related]
6. Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial.
Becker W; Sennerby L; Bedrossian E; Becker BE; Lucchini JP
J Periodontol; 2005 Mar; 76(3):391-7. PubMed ID: 15857073
[TBL] [Abstract][Full Text] [Related]
7. Role of photofunctionalization in mitigating impaired osseointegration associated with type 2 diabetes in rats.
Sugita Y; Honda Y; Kato I; Kubo K; Maeda H; Ogawa T
Int J Oral Maxillofac Implants; 2014; 29(6):1293-300. PubMed ID: 25397793
[TBL] [Abstract][Full Text] [Related]
8. Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values.
Bornstein MM; Hart CN; Halbritter SA; Morton D; Buser D
Clin Implant Dent Relat Res; 2009 Dec; 11(4):338-47. PubMed ID: 19438966
[TBL] [Abstract][Full Text] [Related]
9. Effects of Ultraviolet Photofunctionalization on Bone Augmentation and Integration Capabilities of Titanium Mesh and Implants.
Hirota M; Ikeda T; Tabuchi M; Ozawa T; Tohnai I; Ogawa T
Int J Oral Maxillofac Implants; 2017; 32(1):52-62. PubMed ID: 28095515
[TBL] [Abstract][Full Text] [Related]
10. Comparison of Initial Implant Stability of Implants Placed Using Bicortical Fixation, Indirect Sinus Elevation, and Unicortical Fixation.
Hsu A; Seong WJ; Wolff R; Zhang L; Hodges J; Olin PS; Hinrichs JE
Int J Oral Maxillofac Implants; 2016; 31(2):459-68. PubMed ID: 27004293
[TBL] [Abstract][Full Text] [Related]
11. Development of Implant Stability Quotient values of implants placed with simultaneous sinus floor elevation - results of a prospective study with 109 implants.
Kuchler U; Chappuis V; Bornstein MM; Siewczyk M; Gruber R; Maestre L; Buser D
Clin Oral Implants Res; 2017 Jan; 28(1):109-115. PubMed ID: 26774074
[TBL] [Abstract][Full Text] [Related]
12. Resonance Frequency Analysis of Thermal Acid-Etched, Hydrophilic Implants During First 3 Months of Healing and Osseointegration in an Early-Loading Protocol.
van Eekeren P; Said C; Tahmaseb A; Wismeijer D
Int J Oral Maxillofac Implants; 2015; 30(4):843-50. PubMed ID: 26252037
[TBL] [Abstract][Full Text] [Related]
13. Effect of ultraviolet photofunctionalization of dental titanium implants on osseointegration.
Mehl C; Kern M; Neumann F; Bähr T; Wiltfang J; Gassling V
J Zhejiang Univ Sci B; 2018 Jul; 19(7):525-534. PubMed ID: 29971991
[TBL] [Abstract][Full Text] [Related]
14. Identification of stability changes for immediately placed dental implants.
West JD; Oates TW
Int J Oral Maxillofac Implants; 2007; 22(4):623-30. PubMed ID: 17929524
[TBL] [Abstract][Full Text] [Related]
15. Immediate loading of dental implants supporting fixed partial dentures in the posterior mandible: a randomized controlled split-mouth study--machined versus titanium oxide implant surface.
Schincaglia GP; Marzola R; Scapoli C; Scotti R
Int J Oral Maxillofac Implants; 2007; 22(1):35-46. PubMed ID: 17340895
[TBL] [Abstract][Full Text] [Related]
16. A comparative retrospective study of immediately loaded implants in postextraction sites versus healed sites: results after 6 to 7 years in the maxilla.
Malchiodi L; Ghensi P; Cucchi A; Corrocher G
Int J Oral Maxillofac Implants; 2011; 26(2):373-84. PubMed ID: 21483891
[TBL] [Abstract][Full Text] [Related]
17. Does Length, Diameter, or Bone Quality Affect Primary and Secondary Stability in Self-Tapping Dental Implants?
Gómez-Polo M; Ortega R; Gómez-Polo C; Martín C; Celemín A; Del Río J
J Oral Maxillofac Surg; 2016 Jul; 74(7):1344-53. PubMed ID: 27070843
[TBL] [Abstract][Full Text] [Related]
18. Resonance frequency analysis of one-stage dental implant stability during the osseointegration period.
Ersanli S; Karabuda C; Beck F; Leblebicioglu B
J Periodontol; 2005 Jul; 76(7):1066-71. PubMed ID: 16018748
[TBL] [Abstract][Full Text] [Related]
19. Engineering bone-implant integration with photofunctionalized titanium microfibers.
Park W; Ishijima M; Hirota M; Soltanzadeh P; Ogawa T
J Biomater Appl; 2016 Mar; 30(8):1242-50. PubMed ID: 26656313
[TBL] [Abstract][Full Text] [Related]
20. Alveolar ridge augmentation using anodized implants coated with Escherichia coli-derived recombinant human bone morphogenetic protein 2.
Huh JB; Park CK; Kim SE; Shim KM; Choi KH; Kim SJ; Shim JS; Shin SW
Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jul; 112(1):42-9. PubMed ID: 21194992
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]