These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 27007286)

  • 1. The Carina© middle ear implant: surgical and functional outcomes.
    Bruschini L; Berrettini S; Forli F; Murri A; Cuda D
    Eur Arch Otorhinolaryngol; 2016 Nov; 273(11):3631-3640. PubMed ID: 27007286
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Carina active middle-ear implant with conventional hearing aids for mixed hearing loss.
    Savaş VA; Gündüz B; Karamert R; Cevizci R; Düzlü M; Tutar H; Bayazit YA
    J Laryngol Otol; 2016 Apr; 130(4):340-3. PubMed ID: 26991874
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surgical and audiological outcomes of a fully implantable middle ear implant: early results from a retrospective multicentre study.
    Lau K; Scotta G; Barauna I; da Silva VC; Peixoto MC; Ray J
    Eur Arch Otorhinolaryngol; 2020 Oct; 277(10):2721-2727. PubMed ID: 32372259
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fully implantable Otologics MET Carina(™) device for the treatment of sensorineural and mixed hearing loss: Audio-otological results.
    Bruschini L; Forli F; Passetti S; Bruschini P; Berrettini S
    Acta Otolaryngol; 2010 Oct; 130(10):1147-53. PubMed ID: 20380547
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results.
    Bruschini L; Forli F; Santoro A; Bruschini P; Berrettini S
    Acta Otorhinolaryngol Ital; 2009 Apr; 29(2):79-85. PubMed ID: 20111617
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Totally Implantable Active Middle Ear Implants.
    Seidman MD; Janz TA; Shohet JA
    Otolaryngol Clin North Am; 2019 Apr; 52(2):297-309. PubMed ID: 30770176
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Use of the Carina active middle ear implant in otosclerosis patients].
    Didczuneit-Sandhop B; Langer J
    HNO; 2021 Oct; 69(10):828-834. PubMed ID: 33415345
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Audiologic limitations of Vibrant Soundbridge device: Is the contralateral hearing aid fitting indispensable?
    Jung J; Roh KJ; Moon IS; Kim SH; Hwang KR; Lee JM; Hou JH; Choi JY
    Laryngoscope; 2016 Sep; 126(9):2116-23. PubMed ID: 26774568
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Vibrant Sound Bridge System. A new kind hearing prosthesis for patients with sensorineural hearing loss. 2. Audiological results].
    Lenarz T; Weber BP; Issing PR; Gnadeberg D; Ambjørnsen K; Mack KF; Winter M
    Laryngorhinootologie; 2001 Jul; 80(7):370-80. PubMed ID: 11488147
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fully implantable hearing device with transducer on the round window as a treatment of mixed hearing loss.
    Tringali S; Pergola N; Berger P; Dubreuil C
    Auris Nasus Larynx; 2009 Jun; 36(3):353-8. PubMed ID: 19013036
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The first results of a totally implanted active middle ear device.
    Peixoto MDC; Miranda C; Bento M; Oliveira S; Pratas R; Correia da Silva V
    Eur Arch Otorhinolaryngol; 2019 Oct; 276(10):2775-2781. PubMed ID: 31342145
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Our auditory results using the Vibrant Soundbridge on the long process of the incus: 20 years of data.
    Grégoire A; Van Damme JP; Gilain C; Bihin B; Garin P
    Auris Nasus Larynx; 2018 Feb; 45(1):66-72. PubMed ID: 28285827
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Fully implantable middle ear implant--indications, surgical technique and first results].
    Niemczyk K; Morawski K; Lachowska M; Bartoszewicz R; Sokołowski J; Karchier E
    Otolaryngol Pol; 2011; 65(3):236-40. PubMed ID: 21916227
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outcomes of cochlear implantation in adults with asymmetric hearing loss.
    Franko-Tobin E; Camilon PR; Camposeo E; Holcomb MA; Meyer TA
    Otol Neurotol; 2015 Mar; 36(3):409-15. PubMed ID: 25569365
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The active middle ear implant for the rehabilitation of sensorineural, mixed and conductive hearing losses].
    Sprinzl GM; Wolf-Magele A; Schnabl J; Koci V
    Laryngorhinootologie; 2011 Sep; 90(9):560-72. PubMed ID: 21913153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Binaural hearing restoration with a bilateral fully implantable middle ear implant.
    Cuda D; Murri A; Mainardi A; Forli F; Berrettini S; Bruschini L
    Eur Arch Otorhinolaryngol; 2021 Jul; 278(7):2239-2246. PubMed ID: 32833054
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Totally implantable active middle ear implants: ten years' experience at the University of Tübingen.
    Zenner HP; Rodriguez Jorge J
    Adv Otorhinolaryngol; 2010; 69():72-84. PubMed ID: 20610916
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cochlear implant outcomes in adults and adolescents with early-onset hearing loss.
    Caposecco A; Hickson L; Pedley K
    Ear Hear; 2012; 33(2):209-20. PubMed ID: 21934504
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of active middle ear implants in patients with severe mixed hearing loss.
    Verhaegen VJ; Mulder JJ; Cremers CW; Snik AF
    Otol Neurotol; 2012 Apr; 33(3):297-301. PubMed ID: 22366752
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use.
    Schmerber S; Deguine O; Marx M; Van de Heyning P; Sterkers O; Mosnier I; Garin P; Godey B; Vincent C; Venail F; Mondain M; Deveze A; Lavieille JP; Karkas A
    Eur Arch Otorhinolaryngol; 2017 Apr; 274(4):1835-1851. PubMed ID: 27475796
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.