These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 27007749)

  • 1. Dual Bone Fixation: A Biomechanical Comparison of 3 Implant Constructs in a Mid-Diaphyseal Fracture Model of the Feline Radius and Ulna.
    Preston TJ; Glyde M; Hosgood G; Day RE
    Vet Surg; 2016 Apr; 45(3):289-94. PubMed ID: 27007749
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Properties of the 1.5 mm Locking Compression Plate: Comparison with the 1.5 and 2.0 mm Straight Plates in Compression and Torsion.
    Watrous GK; Moens NMM; Runciman J; Gibson TWG
    Vet Comp Orthop Traumatol; 2018 Nov; 31(6):438-444. PubMed ID: 30357797
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ex vivo biomechanical comparison of a 3.5 mm locking compression plate applied cranially and a 2.7 mm locking compression plate applied medially in a gap model of the distal aspect of the canine radius.
    Uhl JM; Kapatkin AS; Garcia TC; Stover SM
    Vet Surg; 2013 Oct; 42(7):840-6. PubMed ID: 24033354
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of a locking compression plate combined with an intramedullary pin or a polyetheretherketone rod in a cadaveric canine tibia gap model.
    Beierer LH; Glyde M; Day RE; Hosgood GL
    Vet Surg; 2014 Nov; 43(8):1032-8. PubMed ID: 25132257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of mono- and bicortical screws in an experimentally induced gap fracture.
    Demner D; Garcia TC; Serdy MG; Hayashi K; Nir BA; Stover SM
    Vet Comp Orthop Traumatol; 2014; 27(6):422-9. PubMed ID: 25327936
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical Comparison of Two Locking Plate Constructs for the Stabilization of Feline Tibial Fractures.
    Hottmann NM; Johnson MD; Banks SA; Tuyn D; Lewis DD
    Vet Comp Orthop Traumatol; 2020 Mar; 33(2):89-95. PubMed ID: 31858511
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of intramedullary pin size and monocortical screw configuration on locking compression plate-rod constructs in an in vitro fracture gap model.
    Pearson T; Glyde M; Hosgood G; Day R
    Vet Comp Orthop Traumatol; 2015; 28(2):95-103. PubMed ID: 25633043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ex vivo biomechanical evaluation of 2.4 mm LCP plate rod constructs versus 2.7 mm LCP applied to the feline tibia.
    Gutbrod A; Longo F; Affentranger R; Ferguson SJ; Pozzi A; Knell SC
    Vet Surg; 2024 May; 53(4):710-716. PubMed ID: 37818951
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vitro biomechanical comparison of interlocking nail constructs and double plating for fixation of diaphyseal femur fractures in immature horses.
    Radcliffe RM; Lopez MJ; Turner TA; Watkins JP; Radcliffe CH; Markel MD
    Vet Surg; 2001; 30(2):179-90. PubMed ID: 11230773
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro biomechanical comparison of 3.5 string of pearl plate fixation to 3.5 locking compression plate fixation in a canine fracture gap model.
    Malenfant RC; Sod GA
    Vet Surg; 2014 May; 43(4):465-70. PubMed ID: 24720361
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical Comparison of Locking Compression Plate versus Positive Profile Pins and Polymethylmethacrylate for Stabilization of the Canine Lumbar Vertebrae.
    Sturges BK; Kapatkin AS; Garcia TC; Anwer C; Fukuda S; Hitchens PL; Wisner T; Hayashi K; Stover SM
    Vet Surg; 2016 Apr; 45(3):309-18. PubMed ID: 27007649
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model.
    Bruce CW; Gibson TW; Runciman RJ
    Vet Comp Orthop Traumatol; 2014; 27(6):430-5. PubMed ID: 25345445
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stiffness of a type II external skeletal fixator and locking compression plate in a fracture gap model.
    Muro NM; Gilley RS; Kemper AR; Benitez ME; Barry SL; McNally C
    Vet Surg; 2021 Apr; 50(3):622-632. PubMed ID: 33404123
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical Comparison of Locking Compression Plate and Limited Contact Dynamic Compression Plate Combined with an Intramedullary Rod in a Canine Femoral Fracture-Gap Model.
    Matres-Lorenzo L; Diop A; Maurel N; Boucton MC; Bernard F; Bernardé A
    Vet Surg; 2016 Apr; 45(3):319-26. PubMed ID: 26909507
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical comparison of a 3.5-mm conical coupling plating system and a 3.5-mm locking compression plate applied as plate-rod constructs to an experimentally created fracture gap in femurs of canine cadavers.
    Tremolada G; Lewis DD; Paragnani KL; Conrad BP; Kim SE; Pozzi A
    Am J Vet Res; 2017 Jun; 78(6):712-717. PubMed ID: 28541152
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Augmentation of diaphyseal fractures of the radius and ulna in toy breed dogs using a free autogenous omental graft and bone plating.
    Baltzer WI; Cooley S; Warnock JJ; Nemanic S; Stieger-Vanegas SM
    Vet Comp Orthop Traumatol; 2015; 28(2):131-9. PubMed ID: 25703613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Distal Ulna Fractures: A Biomechanical Comparison of Locking Versus Nonlocking Plating Constructs.
    Collins M; Hart A; Hines J; Steffen T; Harvey EJ; Martineau PA
    J Orthop Trauma; 2014 Aug; 28(8):470-5. PubMed ID: 24121982
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Minimally invasive application of a radial plate following placement of an ulnar rod in treating antebrachial fractures. Technique and case series.
    Witsberger TH; Hulse DA; Kerwin SC; Saunders WB
    Vet Comp Orthop Traumatol; 2010; 23(6):459-67. PubMed ID: 20830446
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Biomechanical Comparison of Three Miniature Locking Plate Systems in a Rabbit Radial and Ulnar Fracture Model.
    Takizawa H; Honnami M; Sakai T; Sasaki A; Sakamoto A; Mochizuki M
    Vet Comp Orthop Traumatol; 2019 Jul; 32(4):297-304. PubMed ID: 31319431
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Locking compression plate: a treatment option for diaphyseal nonunion of radius or ulna.
    Ling HT; Kwan MK; Chua YP; Deepak AS; Ahmad TS
    Med J Malaysia; 2006 Dec; 61 Suppl B():8-12. PubMed ID: 17600986
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.