These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

354 related articles for article (PubMed ID: 27016367)

  • 1. Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract.
    Liu G; Yan G; Zhu B; Lu L
    Med Biol Eng Comput; 2016 Nov; 54(11):1779-1791. PubMed ID: 27016367
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Wireless Capsule Endoscope System With Low-Power Controlling and Processing ASIC.
    Xinkai Chen ; Xiaoyu Zhang ; Linwei Zhang ; Xiaowen Li ; Nan Qi ; Hanjun Jiang ; Zhihua Wang
    IEEE Trans Biomed Circuits Syst; 2009 Feb; 3(1):11-22. PubMed ID: 23853159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A complexity-efficient and one-pass image compression algorithm for wireless capsule endoscopy.
    Liu G; Yan G; Zhao S; Kuang S
    Technol Health Care; 2015; 23 Suppl 2():S239-47. PubMed ID: 26410489
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A wireless capsule system with ASIC for monitoring the physiological signals of the human gastrointestinal tract.
    Xu F; Yan G; Zhao K; Lu L; Gao J; Liu G
    IEEE Trans Biomed Circuits Syst; 2014 Dec; 8(6):871-80. PubMed ID: 25608285
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An Ingenious Design of a High Performance-Low Complexity Image Compressor for Wireless Capsule Endoscopy.
    Intzes I; Meng H; Cosmas J
    Sensors (Basel); 2020 Mar; 20(6):. PubMed ID: 32183258
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A UWB wireless capsule endoscopy device.
    Thotahewa KM; Redoute JM; Yuce MR
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6977-80. PubMed ID: 25571601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Integration of Low-Power ASIC and MEMS Sensors for Monitoring Gastrointestinal Tract Using a Wireless Capsule System.
    Arefin MS; Redoute JM; Yuce MR
    IEEE J Biomed Health Inform; 2018 Jan; 22(1):87-97. PubMed ID: 28391213
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Colored Video Analysis in Wireless Capsule Endoscopy: A Survey of State-of-the-Art.
    Ashour AS; Dey N; Mohamed WS; Tromp JG; Sherratt RS; Shi F; Moraru L
    Curr Med Imaging; 2020; 16(9):1074-1084. PubMed ID: 32107996
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An ultra-low-power image compressor for capsule endoscope.
    Lin MC; Dung LR; Weng PK
    Biomed Eng Online; 2006 Feb; 5():14. PubMed ID: 16504138
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Low-power wireless electronic capsule for long-term gastrointestinal monitoring.
    Zhao K; Yan G; Lu L; Xu F
    J Med Syst; 2015 Feb; 39(2):9. PubMed ID: 25631843
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Portable wireless power transmission system for video capsule endoscopy.
    Zhiwei J; Guozheng Y; Bingquan Z
    J Med Eng Technol; 2014 Oct; 38(7):351-8. PubMed ID: 25082182
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of wireless power transmission systems in wireless capsule endoscopy: an overview.
    Basar MR; Ahmad MY; Cho J; Ibrahim F
    Sensors (Basel); 2014 Jun; 14(6):10929-51. PubMed ID: 24949645
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-power ultrawideband wireless telemetry transceiver for medical sensor applications.
    Gao Y; Zheng Y; Diao S; Toh WD; Ang CW; Je M; Heng CH
    IEEE Trans Biomed Eng; 2011 Mar; 58(3):768-72. PubMed ID: 21138797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wireless Capsule Gastrointestinal Endoscopy: Direction-of-Arrival Estimation Based Localization Survey.
    Dey N; Ashour AS; Shi F; Sherratt RS
    IEEE Rev Biomed Eng; 2017; 10():2-11. PubMed ID: 28459696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Recent developments in wireless capsule endoscopy imaging: Compression and summarization techniques.
    B S; P A
    Comput Biol Med; 2022 Oct; 149():106087. PubMed ID: 36115301
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low-power transceiver analog front-end circuits for bidirectional high data rate wireless telemetry in medical endoscopy applications.
    Chi B; Yao J; Han S; Xie X; Li G; Wang Z
    IEEE Trans Biomed Eng; 2007 Jul; 54(7):1291-9. PubMed ID: 17605360
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Therapeutic Wireless Capsule for Treatment of Gastrointestinal Haemorrhage by Balloon Tamponade Effect.
    Leung BHK; Poon CCY; Zhang R; Zheng Y; Chan CKW; Chiu PWY; Lau JYW; Sung JJY
    IEEE Trans Biomed Eng; 2017 May; 64(5):1106-1114. PubMed ID: 27416587
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual-head wireless powered video capsule based on new type of receiving coils.
    Liu G; Yan G; Xu W; Kuang S
    J Med Eng Technol; 2015 May; 39(4):246-52. PubMed ID: 25815581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A two-hop wireless power transfer system with an efficiency-enhanced power receiver for motion-free capsule endoscopy inspection.
    Sun T; Xie X; Li G; Gu Y; Deng Y; Wang Z
    IEEE Trans Biomed Eng; 2012 Nov; 59(11):3247-54. PubMed ID: 22759436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of a lossless image compression system for video capsule endoscopy and its performance in in-vivo trials.
    Khan TH; Wahid KA
    Sensors (Basel); 2014 Nov; 14(11):20779-99. PubMed ID: 25375753
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.