These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 27016455)
1. Development of filter paper hemoglobin A1c assay applicable to newborn screening. Pollock AJ; Allen DB; Wiebe D; Eickhoff J; MacDonald M; Baker M Clin Chim Acta; 2016 Jun; 457():24-6. PubMed ID: 27016455 [TBL] [Abstract][Full Text] [Related]
2. Analysis of hemoglobin A1c from dried blood spot samples with the Tina-quantR II immunoturbidimetric method. Jones TG; Warber KD; Roberts BD J Diabetes Sci Technol; 2010 Mar; 4(2):244-9. PubMed ID: 20307383 [TBL] [Abstract][Full Text] [Related]
3. Comparison of HbA1c detection in whole blood and dried blood spots using an automated ion-exchange HPLC system. Maleska A; Hirtz C; Casteleyn E; Villard O; Ducos J; Avignon A; Sultan A; Lehmann S Bioanalysis; 2017 Mar; 9(5):427-434. PubMed ID: 28220711 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of filter paper method for measuring glycated hemoglobin. Anjali ; Geethanjali FS; Kumar RS; Seshadri MS J Assoc Physicians India; 2007 Feb; 55():115-9. PubMed ID: 17571740 [TBL] [Abstract][Full Text] [Related]
5. Dried Blood Spot Test for Glycated Hemoglobin Measurement in Pediatric Diabetes Care. McNiven M; Thevaranjan N; Yau D; Robertson J; Oluwole O; Buse J; Inman M Can J Diabetes; 2024 Mar; 48(2):74-81. PubMed ID: 37839678 [TBL] [Abstract][Full Text] [Related]
6. Collection and laboratory methods for dried blood spots for hemoglobin A1c and total and high-density lipoprotein cholesterol in population-based surveys. Miller IM; Lacher DA; Chen TC; Zipf GW; Gindi RM; Galinsky AM; Nwankwo T; Terry AL Clin Chim Acta; 2015 May; 445():143-54. PubMed ID: 25818242 [TBL] [Abstract][Full Text] [Related]
7. HPLC-based Measurement of Glycated Hemoglobin using Dried Blood Spots Collected under Adverse Field Conditions. Thomas D; Seeman T; Potter A; Hu P; Crimmins E; Herningtyas EH; Sumantri C; Frankenberg E Biodemography Soc Biol; 2018; 64(1):43-62. PubMed ID: 29741414 [TBL] [Abstract][Full Text] [Related]
8. Comparison of dried blood spot to venous methods for hemoglobin A1c, glucose, total cholesterol, high-density lipoprotein cholesterol, and C-reactive protein. Lacher DA; Berman LE; Chen TC; Porter KS Clin Chim Acta; 2013 Jun; 422():54-8. PubMed ID: 23566929 [TBL] [Abstract][Full Text] [Related]
9. Prospective evaluation of accuracy, precision, and reproducibility of an at-home hemoglobin A1c sampling kit. Parkes J; Ray R; Kerestan S; Davis H; Ginsberg B Diabetes Technol Ther; 1999; 1(4):411-9. PubMed ID: 11474825 [TBL] [Abstract][Full Text] [Related]
10. Pandemic-Associated Trends in Measurement of HbA1c in Children with Diabetes Mellitus and Validation of Dried Blood Spot as an Alternative Sample Matrix. Garnett ER; Recio B; Jung J; Tam E; Devaraj S Ann Clin Lab Sci; 2021 Jul; 51(4):535-539. PubMed ID: 34452892 [TBL] [Abstract][Full Text] [Related]
12. A computer vision approach to the assessment of dried blood spot size and quality in newborn screening. Flynn N; Moat SJ; Hogg SL Clin Chim Acta; 2023 Jul; 547():117418. PubMed ID: 37276944 [TBL] [Abstract][Full Text] [Related]
13. Comparison of Glycated Hemoglobin Results Based on At-Home and In-Lab Dried Blood Spot Sampling to Routine Venous Blood Sampling In-Lab in Adult Patients With Type 1 or Type 2 Diabetes. Elliott TG; Dooley KC; Zhang M; Campbell HSD; Thompson DJS Can J Diabetes; 2018 Aug; 42(4):426-432.e1. PubMed ID: 29282199 [TBL] [Abstract][Full Text] [Related]
14. HPLC analysis of HbA1c in dried blood spot samples (DBS): a reliable future for diabetes monitoring. Lomeo A; Bolner A; Scattolo N; Guzzo P; Amadori F; Sartori S; Lomeo L Clin Lab; 2008; 54(5-6):161-7. PubMed ID: 18780661 [TBL] [Abstract][Full Text] [Related]
15. Adapting to telemedicine in the COVID-19 era: Feasibility of dried blood spot testing for hemoglobin A1c. Roberts AJ; Malik F; Pihoker C; Dickerson JA Diabetes Metab Syndr; 2021; 15(1):433-437. PubMed ID: 33588200 [TBL] [Abstract][Full Text] [Related]
16. Measurement of psychosine in dried blood spots--a possible improvement to newborn screening programs for Krabbe disease. Turgeon CT; Orsini JJ; Sanders KA; Magera MJ; Langan TJ; Escolar ML; Duffner P; Oglesbee D; Gavrilov D; Tortorelli S; Rinaldo P; Raymond K; Matern D J Inherit Metab Dis; 2015 Sep; 38(5):923-9. PubMed ID: 25762404 [TBL] [Abstract][Full Text] [Related]
17. Volumetric absorptive microsampling at home as an alternative tool for the monitoring of HbA1c in diabetes patients. Verougstraete N; Lapauw B; Van Aken S; Delanghe J; Stove C; Stove V Clin Chem Lab Med; 2017 Mar; 55(3):462-469. PubMed ID: 27732552 [TBL] [Abstract][Full Text] [Related]
18. Analysis of HbA1c using microfluidic card (Capitainer qDBS card) as a pre-step before determination of the HbA1c value with an immunological method. Rollborn N; Larsson A; Kultima K Scand J Clin Lab Invest; 2024 Feb; 84(1):11-15. PubMed ID: 38240284 [TBL] [Abstract][Full Text] [Related]
19. The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional study. Mastronardi CA; Whittle B; Tunningley R; Neeman T; Paz-Filho G BMC Clin Pathol; 2015; 15():13. PubMed ID: 26157353 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of hemoglobin A Wu Y; Yang X; Wang H; Li Z; Wang T Scand J Clin Lab Invest; 2017 Apr; 77(2):104-108. PubMed ID: 28097881 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]