731 related articles for article (PubMed ID: 27017367)
1. Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation: The Critical Role of Valve Implantation Height.
De Torres-Alba F; Kaleschke G; Diller GP; Vormbrock J; Orwat S; Radke R; Reinke F; Fischer D; Reinecke H; Baumgartner H
JACC Cardiovasc Interv; 2016 Apr; 9(8):805-813. PubMed ID: 27017367
[TBL] [Abstract][Full Text] [Related]
2. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
[TBL] [Abstract][Full Text] [Related]
3. Clinical outcome and paravalvular leakage of the new balloon-expandable Edwards Sapien 3 valve in comparison to its predecessor model (Edwards Sapien XT) in patients undergoing transfemoral aortic valve replacement.
Bocksch W; Grossmann B; Geisler T; Steeg M; Droppa M; Jorbenadze R; Haap M; Gawaz M; Fateh-Moghadam S
Catheter Cardiovasc Interv; 2016 Sep; 88(3):466-75. PubMed ID: 27184353
[TBL] [Abstract][Full Text] [Related]
4. Device success and 30-day clinical outcome in patients undergoing preimplant valvuloplasty in transfemoral versus omitting valvuloplasty in transapical transcatheter aortic valve replacement.
Wong SC; Pawar S; Minutello RM; Horn EM; Skubas NJ; Devereux RB; Salemi A
J Thorac Cardiovasc Surg; 2015 Nov; 150(5):1111-7. PubMed ID: 26277463
[TBL] [Abstract][Full Text] [Related]
5. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
[TBL] [Abstract][Full Text] [Related]
6. Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation.
Iacovelli F; Pignatelli A; Giugliano G; Stabile E; Cicala M; Salemme L; Cioppa A; Popusoi G; Pucciarelli A; Verdoliva S; Bortone AS; Losi MA; Coscioni E; Esposito G; Contegiacomo G; Tesorio T
Europace; 2018 Jan; 20(1):116-123. PubMed ID: 28339584
[TBL] [Abstract][Full Text] [Related]
7. Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation.
Binder RK; Webb JG; Toggweiler S; Freeman M; Barbanti M; Willson AB; Alhassan D; Hague CJ; Wood DA; Leipsic J
JACC Cardiovasc Interv; 2013 May; 6(5):462-8. PubMed ID: 23702010
[TBL] [Abstract][Full Text] [Related]
8. DynaCT-guided anatomical rotation of the SAPIEN XT valve during transapical aortic valve implantation: proof of concept.
Blumenstein JM; Van Linden A; Moellmann H; Seeburger J; Rastan A; Kim WK; Mohr FW; Kempfert J; Walther T
Thorac Cardiovasc Surg; 2013 Aug; 61(5):409-13. PubMed ID: 23247690
[TBL] [Abstract][Full Text] [Related]
9. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
[TBL] [Abstract][Full Text] [Related]
10. Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation.
Husser O; Kessler T; Burgdorf C; Templin C; Pellegrini C; Schneider S; Kasel AM; Kastrati A; Schunkert H; Hengstenberg C
Rev Esp Cardiol (Engl Ed); 2016 Feb; 69(2):141-8. PubMed ID: 26542175
[TBL] [Abstract][Full Text] [Related]
11. European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1-year outcomes from the SOURCE XT Registry.
Schymik G; Lefèvre T; Bartorelli AL; Rubino P; Treede H; Walther T; Baumgartner H; Windecker S; Wendler O; Urban P; Mandinov L; Thomas M; Vahanian A
JACC Cardiovasc Interv; 2015 Apr; 8(5):657-69. PubMed ID: 25946437
[TBL] [Abstract][Full Text] [Related]
12. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
[TBL] [Abstract][Full Text] [Related]
13. Transfemoral valve-in-valve implantation for degenerated bioprosthetic aortic valves using the new balloon-expandable Edwards Sapien 3 valve.
Gonska B; Seeger J; Rodewald C; Scharnbeck D; Rottbauer W; Wöhrle J
Catheter Cardiovasc Interv; 2016 Oct; 88(4):636-643. PubMed ID: 27142354
[TBL] [Abstract][Full Text] [Related]
14. Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis.
Gonska B; Seeger J; Junker A; Rodewald C; Trepte U; Scharnbeck D; Rottbauer W; Wöhrle J
Arch Cardiovasc Dis; 2018; 111(8-9):470-479. PubMed ID: 29128473
[TBL] [Abstract][Full Text] [Related]
15. Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions.
Schaefer A; Linder M; Treede H; Deuschl F; Schofer N; Seiffert M; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L
Clin Res Cardiol; 2016 Jul; 105(7):585-91. PubMed ID: 26680213
[TBL] [Abstract][Full Text] [Related]
16. Management of paravalvular regurgitation after Edwards SAPIEN transcatheter aortic valve replacement: management of paravalvular regurgitation after TAVR.
Martinez CA; Singh V; O'Neill BP; Alfonso CE; Bilsker MS; Martinez Clark P; Williams D; Cohen MG; Heldman AW; O'Neill WW
Catheter Cardiovasc Interv; 2013 Aug; 82(2):300-11. PubMed ID: 23580318
[TBL] [Abstract][Full Text] [Related]
17. Transfemoral implantation of Edwards Sapien XT aortic valve without previous valvuloplasty: role of 2D/3D transesophageal echocardiography.
García E; Almería C; Unzué L; Jiménez-Quevedo P; Cuadrado A; Macaya C
Catheter Cardiovasc Interv; 2014 Nov; 84(6):868-76. PubMed ID: 24482054
[TBL] [Abstract][Full Text] [Related]
18. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes.
Tan JS; Leipsic J; Perlman G; Stub D; Dvir D; Hansson NC; Norgaard BL; Blanke P; Cheung A; Ye J; Thompson CR; Moss RR; Lauck S; Wood D; Webb J
JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612
[TBL] [Abstract][Full Text] [Related]
19. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
[TBL] [Abstract][Full Text] [Related]
20. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis.
Kamperidis V; van Rosendael PJ; de Weger A; Katsanos S; Regeer M; van der Kley F; Mertens B; Sianos G; Ajmone Marsan N; Bax JJ; Delgado V
JACC Cardiovasc Interv; 2015 Apr; 8(5):670-7. PubMed ID: 25946438
[TBL] [Abstract][Full Text] [Related]