157 related articles for article (PubMed ID: 27025338)
1. Unique nonstructural dysfunction of the omnicarbon valve: case report.
Kurumisawa S; Kaminishi Y; Muraoka A; Misawa Y
J Cardiothorac Surg; 2016 Mar; 11():40. PubMed ID: 27025338
[TBL] [Abstract][Full Text] [Related]
2. Pannus resection through the tilting disc prosthesis: successful treatment preserving the prosthesis.
Misawa Y; Fuse K; Kato M
Artif Organs; 1997 Dec; 21(12):1301-2. PubMed ID: 9423984
[TBL] [Abstract][Full Text] [Related]
3. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].
Nakamura M; Muraoka A; Aizawa K; Akutsu H; Kurumisawa S; Misawa Y
Kyobu Geka; 2015 Jul; 68(7):528-31. PubMed ID: 26197829
[TBL] [Abstract][Full Text] [Related]
4. [Intermittent opening of a mechanical mitral valve prosthesis due to pannus formation; report of a case].
Seo H; Sasaki Y; Hirai H; Hosono M; Sakaguchi M; Nagashima F; Nakahira A; Morisaki A; Okada Y; Suehiro S
Kyobu Geka; 2011 May; 64(5):415-8. PubMed ID: 21591446
[TBL] [Abstract][Full Text] [Related]
5. Acute mitral valve dysfunction due to leaflet escape in a Tri-technologies bileaflet mechanical valve.
Cianciulli TF; Lax JA; Saccheri MC; Redruello HJ; Belforte SM; Picone VP; Prezioso HA
Eur J Echocardiogr; 2007 Jan; 8(1):63-6. PubMed ID: 16434233
[TBL] [Abstract][Full Text] [Related]
6. 'Obstruction alternans' of a Sorin tilting disc prosthetic mitral valve: a case of emergency action.
Rallidis LS; Papadopoulos C; Kanakakis J; Paraskevaidis I; Kremastinos DT
Eur J Echocardiogr; 2008 Sep; 9(5):704-6. PubMed ID: 18490294
[TBL] [Abstract][Full Text] [Related]
7. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.
Cianciulli TF; Lax JA; Saccheri MC; Guidoin R; Salvado CM; Fernández AJ; Prezioso HA
Eur J Echocardiogr; 2008 Jan; 9(1):65-8. PubMed ID: 17045541
[TBL] [Abstract][Full Text] [Related]
8. Prosthetic mitral valve thrombosis, malfunction, and paroxysmal mitral regurgitation.
Moorthy N; Ananthakrishna R; Rao DPV; Manjunath SC; Nanjappa MC
Echocardiography; 2018 Mar; 35(3):388-390. PubMed ID: 29457259
[TBL] [Abstract][Full Text] [Related]
9. Leaflet escape in a TRI bileaflet rotatable mitral valve.
Dikmengil M; Sucu N; Aytacoglu BN; Mavioglu I
J Heart Valve Dis; 2004 Jul; 13(4):638-40. PubMed ID: 15311872
[TBL] [Abstract][Full Text] [Related]
10. [Valve-in-valve replacement of primary tissue valve failure of bovine pericardial valve minor].
Tateishi M; Koide M; Kunii Y; Watanabe K; Ohsawa M
Kyobu Geka; 2006 Jan; 59(1):61-4. PubMed ID: 16440687
[TBL] [Abstract][Full Text] [Related]
11. [Findings of the Carpentier-Edwards porcine bioprosthesis in the mitral position with PTF in the 16th post-operative year].
Matsuzaki K; Koishizawa T; Hiramatsu Y
Kyobu Geka; 1997 Oct; 50(11):950-3. PubMed ID: 9330518
[TBL] [Abstract][Full Text] [Related]
12. [Reoperation for a Starr-Edwards ball valve prosthesis implanted in mitral position 31 years ago].
Goshima M; Shiono M; Yamamoto T; Inoue T; Hata M; Sezai A; Niino T; Nakamura T; Ye Z; Negishi N; Sezai Y
Kyobu Geka; 2003 Jul; 56(7):535-40. PubMed ID: 12854458
[TBL] [Abstract][Full Text] [Related]
13. [Repair of paravalvular leak after a third mitral valve replacement].
Aizawa K; Tateishi A; Sakano Y; Kaminishi Y; Ohki S; Saito T; Konishi H; Kawada M; Misawa Y
Kyobu Geka; 2007 Sep; 60(10):903-5. PubMed ID: 17877009
[TBL] [Abstract][Full Text] [Related]
14. [A case of bioprosthetic mitral valvular dysfunction due to pannus-formation].
Takagi H; Terada Y; Shimoyama Y; Ino T; Wanibuchi Y; Furuta S
Kyobu Geka; 1990 Jul; 43(7):569-72. PubMed ID: 2395253
[TBL] [Abstract][Full Text] [Related]
15. [Mitral valve replacement for four times with three kinds of prosthetic valve dysfunction].
Kojima N; Ito S; Sakano Y; Konishi H; Misawa Y
Kyobu Geka; 2011 Mar; 64(3):225-9. PubMed ID: 21404561
[TBL] [Abstract][Full Text] [Related]
16. Mitral stenosis after mitral valve repair using the duran flexible annuloplasty ring for degenerative mitral regurgitation.
Nishida H; Takahara Y; Takeuchi S; Mogi K
J Heart Valve Dis; 2005 Jul; 14(4):563-4. PubMed ID: 16116886
[TBL] [Abstract][Full Text] [Related]
17. [Reoperation for mitral regurgitation 13 years after aortic valve replacement and manouguian's anulus enlargement: report of a case].
Imanaka K; Furuse A; Murakawa T; Nakajima J; Kozuka Y; Yagyu K
Kyobu Geka; 1997 Dec; 50(13):1101-3. PubMed ID: 9404109
[TBL] [Abstract][Full Text] [Related]
18. Transcatheter valve-in-valve implantation for failed mitral prosthesis: the first experience in Japan.
Tada N; Enta Y; Sakurai M; Ootomo T; Hata M
Cardiovasc Interv Ther; 2017 Jan; 32(1):82-86. PubMed ID: 26711631
[TBL] [Abstract][Full Text] [Related]
19. Resistance to secondary thrombosis of the On-X mitral prosthesis.
Jiritano F; Serraino GF; Rossi M; Pisano G; Renzulli A
J Heart Valve Dis; 2013 Sep; 22(5):740-2. PubMed ID: 24383391
[TBL] [Abstract][Full Text] [Related]
20. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.
Calik ES; Limandal HK; Arslan U; Tort M; Yildiz Z; Bayram E; Dag O; Kaygin MA; Erkut B
Heart Surg Forum; 2015 Dec; 18(6):E245-9. PubMed ID: 26726714
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]