These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 270279)

  • 1. A new parallel plate dialyser. III. Preliminary experience on clinical performance.
    Dawids S; Vojnovic S
    Acta Med Scand Suppl; 1977; 607():27-29. PubMed ID: 270279
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new parallel plate dialyser. II. Description of design and in vitro performance.
    Dawids S; Boe C
    Acta Med Scand Suppl; 1977; 607():17-25. PubMed ID: 270278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new parallel plate dialyser. I. Development and testing of membrane support.
    Dawids S; Boe C
    Acta Med Scand Suppl; 1977; 607():7-16. PubMed ID: 270280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of a new parallel-flow, plate dialyser and a hollow fibre dialyser.
    Sølling J; Hansen HE
    Scand J Urol Nephrol; 1979; 13(3):305-7. PubMed ID: 394310
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Phase one clinical trial of a new composite artificial kidney: a single unit combining dialysis with hemoperfusion.
    Chang TM; Barre P; Kuruvilla S; Messier D; Man N; Resurreccion E
    Trans Am Soc Artif Intern Organs; 1982; 28():43-8. PubMed ID: 7164276
    [No Abstract]   [Full Text] [Related]  

  • 6. Diffusion kinetics of urea, creatinine and uric acid in blood during hemodialysis. Clinical implications.
    Descombes E; Perriard F; Fellay G
    Clin Nephrol; 1993 Nov; 40(5):286-95. PubMed ID: 8281718
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Clinical experiences with Nepross C-02 dialyzer].
    Balcke P; Schmidt P; Zazgornik J; Kopsa H; Pils P
    Acta Med Austriaca; 1977; 4(2):47-9. PubMed ID: 906781
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical and engineering evaluation of disposable envelope inserts for the Kiil dialyzer.
    Nosé Y; Mrava GL; Weber DC; Kon T; Nakamoto S; Popowniak KL; Kuruvila C
    Trans Am Soc Artif Intern Organs; 1969; 15():118-26. PubMed ID: 5791375
    [No Abstract]   [Full Text] [Related]  

  • 9. A comparative evaluation of three high efficiency disposable dialyzers.
    Hoenich NA; Kerr DN
    Clin Nephrol; 1975 Jun; 3(6):211-6. PubMed ID: 1095269
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Clinical testing of the Bulgarian Diamex dialyzers].
    Antonov S; Kiriakov Z; Kuleva V; Krivoshiev S; Velkovski Ts
    Vutr Boles; 1986; 25(3):63-8. PubMed ID: 3532557
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical investigation of the new dialyzer Gambro PRO-3.
    Wehle B; Oja-Pettersson K; Schyllert B; Diehl U; Bergström J
    Blood Purif; 1986; 4(1-3):47-52. PubMed ID: 3730160
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reuse of a disposable dialyser for home dialysis.
    Miach PJ; Evans SM; Wilcox AA; Dawborn JK
    Med J Aust; 1976 Feb; 1(6):146-7. PubMed ID: 1263968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of chronic, intermittent, and short term hemoperfusions in patients with chronic renal failure using semipermeable microcapsules (artificial cells) formed from membrane-coated activated charcoal.
    Chang TM; Gonda A; Dirks JH; Malave N
    Trans Am Soc Artif Intern Organs; 1971; 17():246-52. PubMed ID: 5158100
    [No Abstract]   [Full Text] [Related]  

  • 14. Initial clinical evaluation of the Hospal artificial kidney system.
    Kirkwood RG; O'Brien M; Butruille Y; Lazarus JM; Gottlieb MN; Lowrie EG
    Trans Am Soc Artif Intern Organs; 1978; 24():509-15. PubMed ID: 716049
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A short clinical trial with a new parallel flow hemodialyzer.
    Boner G; Maimon A
    Isr J Med Sci; 1971 Oct; 7(10):1201-3. PubMed ID: 5143186
    [No Abstract]   [Full Text] [Related]  

  • 16. [Comparative studies of the efficiency of MLW-1.3 and 1.8-hollow fiber dialyzers].
    Engelhardt I; Rouvel J; Precht K
    Z Urol Nephrol; 1982 Feb; 75(2):73-9. PubMed ID: 7072396
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The disposable Kiil envelope artificial kidney - in vitro results.
    Mrava GL; Weber DC; Kon T; Lips P; Nosé Y
    Med Res Eng; 1970 Feb; 9(1):23-6. PubMed ID: 5440878
    [No Abstract]   [Full Text] [Related]  

  • 18. [First experiences with the cuprophane coil ExO1].
    Schmidt P; Mayrhofer E; Kotzaurek R
    Wien Med Wochenschr; 1969 May; 119(22):409-11. PubMed ID: 5801628
    [No Abstract]   [Full Text] [Related]  

  • 19. The Gambro Lundia--a new disposable multilayer dialyser.
    Von Hartitzsch B; Hoenich NA; Erickson J; Jolly D; Samson P; Reed BR; Ashcroft R; Clayton CB
    Proc Eur Dial Transplant Assoc; 1972; 9():601-4. PubMed ID: 4668940
    [No Abstract]   [Full Text] [Related]  

  • 20. Clincial performance characteristics of a new combined system for simulatenous hemoperfusion-hemodialysis-ultrafiltration in series.
    Chang TM; Chirito E; Barre B; Cole C; Hewish M
    Trans Am Soc Artif Intern Organs; 1975; 21():502-9. PubMed ID: 1146025
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.