These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
241 related articles for article (PubMed ID: 27028383)
21. Biomechanical effect of 4-rod technique on lumbosacral fixation: an in vitro human cadaveric investigation. Wang T; Liu H; Zheng Z; Li Z; Wang J; Shrivastava SS; Yang H Spine (Phila Pa 1976); 2013 Jul; 38(15):E925-9. PubMed ID: 23609200 [TBL] [Abstract][Full Text] [Related]
22. Cervical disc replacement-porous coated motion prosthesis: a comparative biomechanical analysis showing the key role of the posterior longitudinal ligament. McAfee PC; Cunningham B; Dmitriev A; Hu N; Woo Kim S; Cappuccino A; Pimenta L Spine (Phila Pa 1976); 2003 Oct; 28(20):S176-85. PubMed ID: 14560189 [TBL] [Abstract][Full Text] [Related]
23. Biomechanical evaluation of posterior thoracic transpedicular discectomy. Deniz FE; Brasiliense LB; Lazaro BC; Reyes PM; Sawa AG; Sonntag VK; Crawford NR J Neurosurg Spine; 2010 Aug; 13(2):253-9. PubMed ID: 20672963 [TBL] [Abstract][Full Text] [Related]
24. The role of obesity in the biomechanics and radiological changes of the spine: an in vitro study. Rodriguez-Martinez NG; Perez-Orribo L; Kalb S; Reyes PM; Newcomb AG; Hughes J; Theodore N; Crawford NR J Neurosurg Spine; 2016 Apr; 24(4):615-23. PubMed ID: 26654342 [TBL] [Abstract][Full Text] [Related]
25. Biomechanical analysis of rotational motions after disc arthroplasty: implications for patients with adult deformities. McAfee PC; Cunningham BW; Hayes V; Sidiqi F; Dabbah M; Sefter JC; Hu N; Beatson H Spine (Phila Pa 1976); 2006 Sep; 31(19 Suppl):S152-60. PubMed ID: 16946633 [TBL] [Abstract][Full Text] [Related]
26. Effect of increasing implant height on lumbar spine kinematics and foraminal size using the ProDisc-L prosthesis. Gaffey JL; Ghanayem AJ; Voronov ML; Havey RM; Carandang G; Abjornson C; Patwardhan AG Spine (Phila Pa 1976); 2010 Sep; 35(19):1777-82. PubMed ID: 20700082 [TBL] [Abstract][Full Text] [Related]
27. Biomechanical comparison of single- and two-level cervical arthroplasty versus arthrodesis: effect on adjacent-level spinal kinematics. Cunningham BW; Hu N; Zorn CM; McAfee PC Spine J; 2010 Apr; 10(4):341-9. PubMed ID: 20362252 [TBL] [Abstract][Full Text] [Related]
28. An injectable nucleus pulposus implant restores compressive range of motion in the ovine disc. Malhotra NR; Han WM; Beckstein J; Cloyd J; Chen W; Elliott DM Spine (Phila Pa 1976); 2012 Aug; 37(18):E1099-105. PubMed ID: 22588378 [TBL] [Abstract][Full Text] [Related]
29. Biomechanical evaluation of lateral lumbar interbody fusion with secondary augmentation. Reis MT; Reyes PM; Bse ; Altun I; Newcomb AG; Singh V; Chang SW; Kelly BP; Crawford NR J Neurosurg Spine; 2016 Dec; 25(6):720-726. PubMed ID: 27391398 [TBL] [Abstract][Full Text] [Related]
32. A biomechanical study of the instrumented and adjacent lumbar levels after In-Space interspinous spacer insertion. Park SW; Lim TJ; Park J J Neurosurg Spine; 2010 May; 12(5):560-9. PubMed ID: 20433305 [TBL] [Abstract][Full Text] [Related]
33. Bioabsorbable interbody cages in a sheep cervical spine fusion model. Kandziora F; Pflugmacher R; Scholz M; Eindorf T; Schnake KJ; Haas NP Spine (Phila Pa 1976); 2004 Sep; 29(17):1845-55; discussion 1856. PubMed ID: 15534403 [TBL] [Abstract][Full Text] [Related]
34. Influence of Complex Loading Conditions on Intervertebral Disc Failure. Berger-Roscher N; Casaroli G; Rasche V; Villa T; Galbusera F; Wilke HJ Spine (Phila Pa 1976); 2017 Jan; 42(2):E78-E85. PubMed ID: 27187053 [TBL] [Abstract][Full Text] [Related]
36. Total disc replacement arthroplasty using the AcroFlex lumbar disc: a non-human primate model. Cunningham BW; Lowery GL; Serhan HA; Dmitriev AE; Orbegoso CM; McAfee PC; Fraser RD; Ross RE; Kulkarni SS Eur Spine J; 2002 Oct; 11 Suppl 2(Suppl 2):S115-23. PubMed ID: 12384732 [TBL] [Abstract][Full Text] [Related]
37. [Biomechanical evaluation of effects of percutaneous cement discoplasty and percutaneous cement interbody fusion on spinal stability]. Li S; Shao P; Xu B; Liu Y; Zhang J; Liu G; Zhang H; Guo Z; Li X; Hu Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Nov; 36(11):1407-1412. PubMed ID: 36382460 [TBL] [Abstract][Full Text] [Related]
38. [Biomechanics changes of lumbar spine caused by foraminotomy via percutaneous transforaminal endoscopic lumbar discectomy]. Qian J; Yu SS; Liu JJ; Chen L; Jing JH Zhonghua Yi Xue Za Zhi; 2018 Apr; 98(13):1013-1018. PubMed ID: 29690712 [No Abstract] [Full Text] [Related]
39. Defining the Neutral Zone of sheep intervertebral joints during dynamic motions: an in vitro study. Thompson RE; Barker TM; Pearcy MJ Clin Biomech (Bristol); 2003 Feb; 18(2):89-98. PubMed ID: 12550806 [TBL] [Abstract][Full Text] [Related]
40. Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Cunningham BW; Gordon JD; Dmitriev AE; Hu N; McAfee PC Spine (Phila Pa 1976); 2003 Oct; 28(20):S110-7. PubMed ID: 14560182 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]