These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 27040207)

  • 1. Evaluation of physicochemical properties of SiO2-coated stainless steel after sterilization.
    Walke W; Paszenda Z; Pustelny T; Opilski Z; Drewniak S; Kościelniak-Ziemniak M; Basiaga M
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():155-63. PubMed ID: 27040207
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biological effects of sol-gel derived ZrO2 and SiO2/ZrO2 coatings on stainless steel surface--In vitro model using mesenchymal stem cells.
    Smieszek A; Donesz-Sikorska A; Grzesiak J; Krzak J; Marycz K
    J Biomater Appl; 2014 Nov; 29(5):699-714. PubMed ID: 25074359
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhancement of biocompatibility of 316LVM stainless steel by cyclic potentiodynamic passivation.
    Shahryari A; Omanovic S; Szpunar JA
    J Biomed Mater Res A; 2009 Jun; 89(4):1049-62. PubMed ID: 18478556
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Degradation of 316L stainless steel sternal wire by steam sterilization.
    Shih CC; Su YY; Chen LC; Shih CM; Lin SJ
    Acta Biomater; 2010 Jun; 6(6):2322-8. PubMed ID: 20025998
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A combination of interdisciplinary analytical tools for evaluation of multi-layered coatings on medical grade stainless steel for biomedical applications.
    Maver U; Xhanari K; Žižek M; Korte D; Gradišnik L; Franko M; Finšgar M
    Eur J Pharm Biopharm; 2018 Jul; 128():230-246. PubMed ID: 29730258
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications.
    Haïdopoulos M; Turgeon S; Sarra-Bournet C; Laroche G; Mantovani D
    J Mater Sci Mater Med; 2006 Jul; 17(7):647-57. PubMed ID: 16770550
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bone quality around bioactive silica-based coated stainless steel implants: analysis by micro-Raman, XRF and XAS techniques.
    Ballarre J; Desimone PM; Chorro M; Baca M; Orellano JC; Ceré SM
    J Struct Biol; 2013 Nov; 184(2):164-72. PubMed ID: 24076155
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Study of bioactive nano-multiplayer films on medical stainless steel fabrication and haemocompatibility].
    Yue L; Zhao H; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):108-12. PubMed ID: 18435269
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Sr on the bioactivity and corrosion resistance of nanoporous niobium oxide coating for orthopaedic applications.
    Pauline SA; Rajendran N
    Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():194-205. PubMed ID: 24433904
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Localized corrosion of 316L stainless steel with SiO2-CaO films obtained by means of sol-gel treatment.
    Vallet-Regí M; Izquierdo-Barba I; Gil FJ
    J Biomed Mater Res A; 2003 Nov; 67(2):674-8. PubMed ID: 14566812
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion protection performance of porous strontium hydroxyapatite coating on polypyrrole coated 316L stainless steel.
    Gopi D; Ramya S; Rajeswari D; Kavitha L
    Colloids Surf B Biointerfaces; 2013 Jul; 107():130-6. PubMed ID: 23475060
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of graphene oxide interlayer on corrosion barrier and bioactive properties of electrophoretically deposited ZrO
    Mahmoudi M; Farhadian M; Raeissi K; Labbaf S; Karimzadeh F; Golozar MA; Barnoush A
    Mater Sci Eng C Mater Biol Appl; 2020 Dec; 117():111342. PubMed ID: 32919689
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduced platelet adhesion and improved corrosion resistance of superhydrophobic TiO₂-nanotube-coated 316L stainless steel.
    Huang Q; Yang Y; Hu R; Lin C; Sun L; Vogler EA
    Colloids Surf B Biointerfaces; 2015 Jan; 125():134-41. PubMed ID: 25481855
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biocompatible carbohydrate-functionalized stainless steel surfaces: a new method for passivating biomedical implants.
    Slaney AM; Wright VA; Meloncelli PJ; Harris KD; West LJ; Lowary TL; Buriak JM
    ACS Appl Mater Interfaces; 2011 May; 3(5):1601-12. PubMed ID: 21438637
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preparation and characterization of sol-gel hydroxyapatite and its electrochemical evaluation for biomedical applications.
    Vijayalakshmi U; Prabakaran K; Rajeswari S
    J Biomed Mater Res A; 2008 Dec; 87(3):739-49. PubMed ID: 18200538
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires.
    Kim H; Johnson JW
    Angle Orthod; 1999 Feb; 69(1):39-44. PubMed ID: 10022183
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of strontium and magnesium substituted porous hydroxyapatite/poly(3,4-ethylenedioxythiophene) coating on surgical grade stainless steel and its bioactivity on osteoblast cells.
    Gopi D; Ramya S; Rajeswari D; Surendiran M; Kavitha L
    Colloids Surf B Biointerfaces; 2014 Feb; 114():234-40. PubMed ID: 24200951
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of bone marrow and adipose-derived mesenchymal stem cells for testing the biocompatibility of metal-based biomaterials functionalized with ascorbic acid.
    Marycz K; Śmieszek A; Grzesiak J; Donesz-Sikorska A; Krzak-Roś J
    Biomed Mater; 2013 Dec; 8(6):065004. PubMed ID: 24280658
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Corrosion and haemocompatibility of 316L stainless steel with electroplated Rh film].
    Liu J; Yang D; Liang C; Guo L; Kong L; Cai Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Jun; 18(2):169-72. PubMed ID: 11450526
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chemical nanocavitation of surfaces to enhance the utility of stainless steel as a medical material.
    Rodriguez-Contreras A; Guadarrama Bello D; Flynn S; Variola F; Wuest JD; Nanci A
    Colloids Surf B Biointerfaces; 2018 Jan; 161():677-687. PubMed ID: 29175762
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.