These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. The second-order differential phase contrast and its retrieval for imaging with x-ray Talbot interferometry. Yang Y; Tang X Med Phys; 2012 Dec; 39(12):7237-53. PubMed ID: 23231275 [TBL] [Abstract][Full Text] [Related]
4. Accurate effective atomic number determination with polychromatic grating-based phase-contrast computed tomography. Birnbacher L; Willner M; Marschner M; Pfeiffer D; Pfeiffer F; Herzen J Opt Express; 2018 Jun; 26(12):15153-15166. PubMed ID: 30114766 [TBL] [Abstract][Full Text] [Related]
5. Spherical grating based x-ray Talbot interferometry. Cong W; Xi Y; Wang G Med Phys; 2015 Nov; 42(11):6514-9. PubMed ID: 26520741 [TBL] [Abstract][Full Text] [Related]
6. High sensitivity X-ray phase contrast imaging by laboratory grating-based interferometry at high Talbot order geometry. Vila-Comamala J; Romano L; Jefimovs K; Dejea H; Bonnin A; Cook AC; Planinc I; Cikes M; Wang Z; Stampanoni M Opt Express; 2021 Jan; 29(2):2049-2064. PubMed ID: 33726406 [TBL] [Abstract][Full Text] [Related]
7. Performance evaluation of x-ray differential phase contrast computed tomography (PCT) with respect to medical imaging. Raupach R; Flohr T Med Phys; 2012 Aug; 39(8):4761-74. PubMed ID: 22894401 [TBL] [Abstract][Full Text] [Related]
8. Tilted grating phase-contrast computed tomography using statistical iterative reconstruction. Birnbacher L; Viermetz M; Noichl W; Allner S; Fehringer A; Marschner M; von Teuffenbach M; Willner M; Achterhold K; Noël PB; Koehler T; Herzen J; Pfeiffer F Sci Rep; 2018 Apr; 8(1):6608. PubMed ID: 29700372 [TBL] [Abstract][Full Text] [Related]
9. Helical differential X-ray phase-contrast computed tomography. Fu J; Willner M; Chen L; Tan R; Achterhold K; Bech M; Herzen J; Kunka D; Mohr J; Pfeiffer F Phys Med; 2014 May; 30(3):374-9. PubMed ID: 24518822 [TBL] [Abstract][Full Text] [Related]
10. Choosing sensitivity to reduce X-ray dose in medical phase contrast imaging. Preusche O Opt Express; 2018 Apr; 26(8):10339-10357. PubMed ID: 29715972 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of phase-contrast CT of breast tissue at conventional X-ray sources - presentation of selected findings. Grandl S; Willner M; Herzen J; Mayr D; Auweter SD; Hipp A; Pfeiffer F; Reiser M; Hellerhoff K Z Med Phys; 2013 Sep; 23(3):212-21. PubMed ID: 23489931 [TBL] [Abstract][Full Text] [Related]
12. Simulation study on X-ray phase contrast imaging with dual-phase gratings. Bopp J; Ludwig V; Seifert M; Pelzer G; Maier A; Anton G; Riess C Int J Comput Assist Radiol Surg; 2019 Jan; 14(1):3-10. PubMed ID: 30349975 [TBL] [Abstract][Full Text] [Related]
13. Grating-based x-ray differential phase contrast imaging with twin peaks in phase-stepping curves-phase retrieval and dewrapping. Yang Y; Xie H; Cai W; Mao H; Tang X Med Phys; 2016 Jun; 43(6):2855-2869. PubMed ID: 27277034 [TBL] [Abstract][Full Text] [Related]
14. Analysis and correction of bias induced by phase stepping jitter in grating-based X-ray phase-contrast imaging. De Marco F; Marschner M; Birnbacher L; Noël P; Herzen J; Pfeiffer F Opt Express; 2018 May; 26(10):12707-12722. PubMed ID: 29801307 [TBL] [Abstract][Full Text] [Related]
15. Sensitivity of X-ray grating interferometry. Modregger P; Pinzer BR; Thüring T; Rutishauser S; David C; Stampanoni M Opt Express; 2011 Sep; 19(19):18324-38. PubMed ID: 21935201 [TBL] [Abstract][Full Text] [Related]
16. A general theory of interference fringes in x-ray phase grating imaging. Yan A; Wu X; Liu H Med Phys; 2015 Jun; 42(6):3036-47. PubMed ID: 26127056 [TBL] [Abstract][Full Text] [Related]
17. X-ray phase-contrast tomosynthesis for improved breast tissue discrimination. Schleede S; Bech M; Grandl S; Sztrókay A; Herzen J; Mayr D; Stockmar M; Potdevin G; Zanette I; Rack A; Weitkamp T; Pfeiffer F Eur J Radiol; 2014 Mar; 83(3):531-6. PubMed ID: 24387825 [TBL] [Abstract][Full Text] [Related]
18. Optimisation of image reconstruction for phase-contrast x-ray Talbot-Lau imaging with regard to mechanical robustness. Seifert M; Kaeppler S; Hauke C; Horn F; Pelzer G; Rieger J; Michel T; Riess C; Anton G Phys Med Biol; 2016 Sep; 61(17):6441-64. PubMed ID: 27514576 [TBL] [Abstract][Full Text] [Related]
19. Development of X-ray phase CT with a hybrid configuration of Lau and Talbot-Lau interferometers. Kageyama M; Okajima K; Maesawa M; Nonoguchi M; Nonoguchi M; Kuribayashi M; Hara Y; Momose A J Xray Sci Technol; 2021; 29(1):63-73. PubMed ID: 33164981 [TBL] [Abstract][Full Text] [Related]
20. Phase unwrapping in spectral X-ray differential phase-contrast imaging with an energy-resolving photon-counting pixel detector. Epple FM; Ehn S; Thibault P; Koehler T; Potdevin G; Herzen J; Pennicard D; Graafsma H; Noël PB; Pfeiffer F IEEE Trans Med Imaging; 2015 Mar; 34(3):816-23. PubMed ID: 25163054 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]