These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 27043423)

  • 1. Coronary Artery Variants and Anomalies in Patients With Bicuspid Aortic Valve.
    Michałowska IM; Hryniewiecki T; Kwiatek P; Stokłosa P; Swoboda-Rydz U; Szymański P
    J Thorac Imaging; 2016 May; 31(3):156-62. PubMed ID: 27043423
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The impact of coronary anomalies on the outcome in aortic valve surgery: comparison of bicuspid aortic valve versus tricuspid aortic valve morphotype.
    Naito S; Petersen J; Reichenspurner H; Girdauskas E
    Interact Cardiovasc Thorac Surg; 2018 Apr; 26(4):617-622. PubMed ID: 29244161
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ascending aortic dilatation is rarely associated with coronary artery disease regardless of aortic valve morphology.
    Jackson V; Eriksson MJ; Caidahl K; Eriksson P; Franco-Cereceda A
    J Thorac Cardiovasc Surg; 2014 Dec; 148(6):2973-80.e1. PubMed ID: 25242056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Focus on the unique mechanisms involved in thoracic aortic aneurysm formation in bicuspid aortic valve versus tricuspid aortic valve patients: clinical implications of a pilot study.
    Balistreri CR; Pisano C; Candore G; Maresi E; Codispoti M; Ruvolo G
    Eur J Cardiothorac Surg; 2013 Jun; 43(6):e180-6. PubMed ID: 23248206
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of Valve Morphology on the Prevalence of Coronary Artery Disease: A Systematic Review and Meta-Analysis.
    Poggio P; Cavallotti L; Songia P; Di Minno A; Ambrosino P; Mammana L; Parolari A; Alamanni F; Tremoli E; Di Minno MN
    J Am Heart Assoc; 2016 May; 5(5):. PubMed ID: 27194004
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The bicuspid aortic valve and its relation to aortic dilation.
    Yuan SM; Jing H; Lavee J
    Clinics (Sao Paulo); 2010 May; 65(5):497-505. PubMed ID: 20535368
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Patterns of ascending aortic dilatation and predictors of surgical replacement of the aorta: A comparison of bicuspid and tricuspid aortic valve patients over eight years of follow-up.
    Agnese V; Pasta S; Michelena HI; Minà C; Romano GM; Carerj S; Zito C; Maalouf JF; Foley TA; Raffa G; Clemenza F; Pilato M; Bellavia D
    J Mol Cell Cardiol; 2019 Oct; 135():31-39. PubMed ID: 31348923
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies.
    Philip F; Faza NN; Schoenhagen P; Desai MY; Tuzcu EM; Svensson LG; Kapadia SR
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):E88-98. PubMed ID: 25914355
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Aortic Valve Replacement on Aortic Root Dilatation Rate in Patients With Bicuspid and Tricuspid Aortic Valves.
    Regeer MV; Versteegh MI; Klautz RJ; Schalij MJ; Bax JJ; Marsan NA; Delgado V
    Ann Thorac Surg; 2016 Dec; 102(6):1981-1987. PubMed ID: 27457830
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coexistent bicuspid aortic valve and mitral valve prolapse: epidemiology, phenotypic spectrum, and clinical implications.
    Padang R; Enriquez-Sarano M; Pislaru SV; Maalouf JF; Nkomo VT; Mankad SV; Maltais S; Suri RM; Schaff HV; Michelena HI
    Eur Heart J Cardiovasc Imaging; 2019 Jun; 20(6):677-686. PubMed ID: 30445616
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fused aortic valve without an elliptical-shaped systolic orifice in patients with severe aortic stenosis: cardiac computed tomography is useful for differentiation between bicuspid aortic valve with raphe and tricuspid aortic valve with commissural fusion.
    Bak SH; Ko SM; Song MG; Shin JK; Chee HK; Kim JS
    Eur Radiol; 2015 Apr; 25(4):1208-17. PubMed ID: 25424562
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical properties of the thoracic aneurysmal wall: differences between bicuspid aortic valve and tricuspid aortic valve patients.
    Forsell C; Björck HM; Eriksson P; Franco-Cereceda A; Gasser TC
    Ann Thorac Surg; 2014 Jul; 98(1):65-71. PubMed ID: 24881863
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thoracic aortic atherosclerosis in patients with a bicuspid aortic valve; a case-control study.
    Dolmaci OB; Klautz RJM; Poelmann RE; Lindeman JHN; Sprengers R; Kroft L; Grewal N
    BMC Cardiovasc Disord; 2023 Jul; 23(1):363. PubMed ID: 37468858
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcatheter aortic valve replacement for patients with severe bicuspid aortic stenosis.
    Pineda AM; Rymer J; Wang A; Banks AZ; Koweek LH; Plichta R; Williams A; Vavalle JP; Halim S; Kiefer T; Wang A; Gaca J; Hughes GC; Harrison JK
    Am Heart J; 2020 Jun; 224():105-112. PubMed ID: 32361278
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Patients With Bicuspid Aortic Stenosis Demonstrate Adverse Left Ventricular Remodeling and Impaired Cardiac Function Before Surgery With Increased Risk of Postoperative Heart Failure.
    Wedin JO; Vedin O; Rodin S; Simonson OE; Hörsne Malmborg J; Pallin J; James SK; Flachskampf FA; Ståhle E; Grinnemo KH
    Circulation; 2022 Oct; 146(17):1310-1322. PubMed ID: 35971843
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative evaluation of coronary disease burden: bicuspid valve disease is not atheroprotective.
    Dolmaci OB; Driessen AHG; Klautz RJM; Poelmann R; Lindeman JHN; Grewal N
    Open Heart; 2021 Sep; 8(2):. PubMed ID: 34497063
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Coronary anatomy in Turner syndrome versus patients with isolated bicuspid aortic valves.
    Koenraadt WMC; Siebelink HJ; Bartelings MM; Schalij MJ; van der Vlugt MJ; van den Bosch AE; Budde RPJ; Roos-Hesselink JW; Duijnhouwer AL; van den Hoven AT; DeRuiter MC; Jongbloed MRM
    Heart; 2019 May; 105(9):701-707. PubMed ID: 30368485
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcatheter aortic valve replacement in bicuspid aortic valve disease.
    Mylotte D; Lefevre T; Søndergaard L; Watanabe Y; Modine T; Dvir D; Bosmans J; Tchetche D; Kornowski R; Sinning JM; Thériault-Lauzier P; O'Sullivan CJ; Barbanti M; Debry N; Buithieu J; Codner P; Dorfmeister M; Martucci G; Nickenig G; Wenaweser P; Tamburino C; Grube E; Webb JG; Windecker S; Lange R; Piazza N
    J Am Coll Cardiol; 2014 Dec; 64(22):2330-9. PubMed ID: 25465419
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In Silico Shear and Intramural Stresses are Linked to Aortic Valve Morphology in Dilated Ascending Aorta.
    Pasta S; Gentile G; Raffa GM; Bellavia D; Chiarello G; Liotta R; Luca A; Scardulla C; Pilato M
    Eur J Vasc Endovasc Surg; 2017 Aug; 54(2):254-263. PubMed ID: 28655506
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bicuspid Aortic Valve Anatomy and Relationship With Devices: The BAVARD Multicenter Registry.
    Tchetche D; de Biase C; van Gils L; Parma R; Ochala A; Lefevre T; Hovasse T; De Backer O; Sondergaard L; Bleiziffer S; Lange R; Kornowski R; Landes U; Norgaard BL; Biasco L; Philippart R; Molina-Martin de Nicolas J; Mylotte D; Lemee C; Dumonteil N; Van Mieghem NM
    Circ Cardiovasc Interv; 2019 Jan; 12(1):e007107. PubMed ID: 30626202
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.