These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
180 related articles for article (PubMed ID: 27045318)
1. Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem. Mukka S; Mellner C; Knutsson B; Sayed-Noor A; Sköldenberg O Acta Orthop; 2016 Jun; 87(3):257-61. PubMed ID: 27045318 [TBL] [Abstract][Full Text] [Related]
2. Increased risk for postoperative periprosthetic fracture in hip fracture patients with the Exeter stem than the anatomic SP2 Lubinus stem. Mellner C; Mohammed J; Larsson M; Esberg S; Szymanski M; Hellström N; Chang C; Berg HE; Sköldenberg O; Knutsson B; Morberg P; Mukka S Eur J Trauma Emerg Surg; 2021 Jun; 47(3):803-809. PubMed ID: 31740996 [TBL] [Abstract][Full Text] [Related]
4. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem. Brodén C; Mukka S; Muren O; Eisler T; Boden H; Stark A; Sköldenberg O Acta Orthop; 2015 Apr; 86(2):169-74. PubMed ID: 25280133 [TBL] [Abstract][Full Text] [Related]
5. Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years. Mohammed J; Mukka S; Hedbeck CJ; Chammout G; Gordon M; Sköldenberg O Acta Orthop; 2019 Oct; 90(5):427-432. PubMed ID: 31154885 [TBL] [Abstract][Full Text] [Related]
6. Polished, Collarless, Tapered, Cemented Stems for Primary Hip Arthroplasty May Exhibit High Rate of Periprosthetic Fracture at Short-Term Follow-Up. Scott T; Salvatore A; Woo P; Lee YY; Salvati EA; Gonzalez Della Valle A J Arthroplasty; 2018 Apr; 33(4):1120-1125. PubMed ID: 29223405 [TBL] [Abstract][Full Text] [Related]
7. More reoperations for periprosthetic fracture after cemented hemiarthroplasty with polished taper-slip stems than after anatomical and straight stems in the treatment of hip fractures: a study from the Norwegian Hip Fracture Register 2005 to 2016. Kristensen TB; Dybvik E; Furnes O; Engesæter LB; Gjertsen JE Bone Joint J; 2018 Dec; 100-B(12):1565-1571. PubMed ID: 30499310 [TBL] [Abstract][Full Text] [Related]
8. Postoperative periprosthetic fractures in patients with an Exeter stem due to a femoral neck fracture: cumulative incidence and surgical outcome. Inngul C; Enocson A Int Orthop; 2015 Sep; 39(9):1683-8. PubMed ID: 25341951 [TBL] [Abstract][Full Text] [Related]
9. Substantially higher prevalence of postoperative periprosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem: A prospective cohort study involving 979 hips. Garellick G; Kärrholm J; Lindahl H; Chatziagorou G; Mukka S; Mellner C; Knutsson B; Sayed-Noor A; Sköldenberg O Acta Orthop; 2016 Dec; 87(6):653. PubMed ID: 27784189 [No Abstract] [Full Text] [Related]
10. Increased risk of periprosthetic femur fractures associated with a unique cementless stem design. Watts CD; Abdel MP; Lewallen DG; Berry DJ; Hanssen AD Clin Orthop Relat Res; 2015 Jun; 473(6):2045-53. PubMed ID: 25502478 [TBL] [Abstract][Full Text] [Related]
11. Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience. Abdel MP; Houdek MT; Watts CD; Lewallen DG; Berry DJ Bone Joint J; 2016 Apr; 98-B(4):468-74. PubMed ID: 27037428 [TBL] [Abstract][Full Text] [Related]
12. A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacement. Grammatopoulos G; Pandit H; Kambouroglou G; Deakin M; Gundle R; McLardy-Smith P; Taylor A; Murray D Injury; 2011 Nov; 42(11):1271-6. PubMed ID: 21315343 [TBL] [Abstract][Full Text] [Related]
13. Cumulative Long-Term Incidence of Postoperative Periprosthetic Femoral Fractures Using an Uncemented Tapered Titanium Hip Stem: 26- to 32-Year Results. Peitgen DS; Innmann MM; Merle C; Gotterbarm T; Moradi B; Streit MR J Arthroplasty; 2019 Jan; 34(1):77-81. PubMed ID: 30274947 [TBL] [Abstract][Full Text] [Related]
14. Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review. Baryeh K; Sochart DH Arch Orthop Trauma Surg; 2022 Dec; 142(12):4075-4085. PubMed ID: 35048171 [TBL] [Abstract][Full Text] [Related]
15. Periprosthetic fracture in the elderly with anatomic modular cementless hemiarthroplasty. Kouyoumdjian P; Dhenin A; Dupeyron A; Coulomb R; Asencio G Orthop Traumatol Surg Res; 2016 Oct; 102(6):701-5. PubMed ID: 27496660 [TBL] [Abstract][Full Text] [Related]
16. Periprosthetic femoral fractures around the original cemented polished triple-tapered C-stem femoral implant: a consecutive series of 500 primary total hip arthroplasties with an average follow-up of 15 years. Baryeh K; Wang C; Sochart DH Arch Orthop Trauma Surg; 2023 Jul; 143(7):4511-4518. PubMed ID: 36447057 [TBL] [Abstract][Full Text] [Related]
17. Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component. A follow-up study at a minimum of ten years. Firestone DE; Callaghan JJ; Liu SS; Goetz DD; Sullivan PM; Vittetoe DA; Johnston RC J Bone Joint Surg Am; 2007 Jan; 89(1):126-32. PubMed ID: 17200319 [TBL] [Abstract][Full Text] [Related]
18. The design of the cemented stem influences the risk of Vancouver type B fractures, but not of type C: an analysis of 82,837 Lubinus SPII and Exeter Polished stems. Chatziagorou G; Lindahl H; Kärrholm J Acta Orthop; 2019 Apr; 90(2):135-142. PubMed ID: 30739553 [TBL] [Abstract][Full Text] [Related]
19. The influence of cemented femoral stem choice on the incidence of revision for periprosthetic fracture after primary total hip arthroplasty: an analysis of national joint registry data. Palan J; Smith MC; Gregg P; Mellon S; Kulkarni A; Tucker K; Blom AW; Murray DW; Pandit H Bone Joint J; 2016 Oct; 98-B(10):1347-1354. PubMed ID: 27694588 [TBL] [Abstract][Full Text] [Related]
20. Higher periprosthetic fracture rate associated with use of modern uncemented stems compared to cemented stems in femoral neck fractures. Song JSA; Dillman D; Wilson D; Dunbar M; Richardson G Hip Int; 2019 Mar; 29(2):177-183. PubMed ID: 29682992 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]