These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 27046088)

  • 41. Ultrapure dialysate and inflammatory response in haemodialysis evaluated by darbepoetin requirements--a randomized study.
    Lamas JM; Alonso M; Sastre F; García-Trío G; Saavedra J; Palomares L
    Nephrol Dial Transplant; 2006 Oct; 21(10):2851-8. PubMed ID: 16822792
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Survival with low- and high-flux dialysis.
    Sánchez-Álvarez E; Rodríguez-García M; Locatelli F; Zoccali C; Martín-Malo A; Floege J; Ketteler M; London G; Górriz JL; Rutkowski B; Ferreira A; Pavlovic D; Cannata-Andía JB; Fernández-Martín JL;
    Clin Kidney J; 2021 Aug; 14(8):1915-1923. PubMed ID: 34345415
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Differences in bio-incompatibility among four biocompatible dialyzer membranes using in maintenance hemodialysis patients.
    Zhang DL; Liu J; Cui WY; Ji DY; Zhang Y; Liu WH
    Ren Fail; 2011; 33(7):682-91. PubMed ID: 21787159
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Association between haemoglobin level and all-cause mortality in haemodialysis patients: the link with inflammation and malnutrition.
    Selim G; Stojceva-Taneva O; Sikole A; Amitov V; Trajcevska L; Asani A; Trojacanec-Piponska S; Polenakovic M
    Prilozi; 2007 Jul; 28(1):81-95. PubMed ID: 17921920
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Evaluation of oxidant-antioxidant balance in patients on maintenance haemodialysis: a comparative study of dialyzers membranes.
    Macías Núñez JF; Ghais Z; Bustamante J; Lopez-Novoa JM; Arrieta J; Barril G; Del Pino MD; Escaja C; Martín IM; Fernández Andrade C; García F; Núñez J; Onaindía JM; González J; Pérez-Prieto M; Fernández M; Lopez J; Santiago JM; Vicens M; Sousa F
    Nephron Clin Pract; 2010; 114(1):c67-73. PubMed ID: 19816045
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Dialysis filter type determines the acute effect of haemodialysis on endothelial function and oxidative stress.
    Kosch M; Levers A; Fobker M; Barenbrock M; Schaefer RM; Rahn KH; Hausberg M
    Nephrol Dial Transplant; 2003 Jul; 18(7):1370-5. PubMed ID: 12808175
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Pegylated interferon-alpha2a kinetics during experimental haemodialysis: impact of permeability and pore size of dialysers.
    Barril G; Quiroga JA; Sanz P; Rodrìguez-Salvanés F; Selgas R; Carreño V
    Aliment Pharmacol Ther; 2004 Jul; 20(1):37-44. PubMed ID: 15225169
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Current peritoneal dialysis compared with haemodialysis: medium-term survival analysis of incident dialysis patients in the Canary Islands in recent years].
    Rufino JM; García C; Vega N; Macía M; Hernández D; Rodríguez A; Maceira B; Lorenzo V
    Nefrologia; 2011; 31(2):174-84. PubMed ID: 21461011
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Biocompatibility and permeability of dialyzer membranes do not affect anemia, erythropoietin dosage or mortality in japanese patients on chronic non-reuse hemodialysis: a prospective cohort study from the J-DOPPS II study.
    Yokoyama H; Kawaguchi T; Wada T; Takahashi Y; Higashi T; Yamazaki S; Fukuhara S; Akiba T; Akizawa T; Asano Y; Kurokawa K; Saito A;
    Nephron Clin Pract; 2008; 109(2):c100-8. PubMed ID: 18596379
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Effects of different dialysis membranes and techniques on the nutritional status, morbidity and mortality of hemodialysis patients].
    Chiappini MG; Ammann T; Selvaggi G; Bravi M; Traietti P
    G Ital Nefrol; 2004; 21 Suppl 30():S190-6. PubMed ID: 15750983
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Randomized trial of high-flux vs low-flux haemodialysis: effects on homocysteine and lipids.
    House AA; Wells GA; Donnelly JG; Nadler SP; Hébert PC
    Nephrol Dial Transplant; 2000 Jul; 15(7):1029-34. PubMed ID: 10862642
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Evaluation of Proteins and Cells that Adsorb to Dialysis Membranes Used in Continuous Hemodiafiltration: Comparison of AN69ST, Polymethylmethacrylate, and Polysulfone Membranes.
    Michikoshi J; Matsumoto S; Miyawaki H; Morita M; Niu H; Seo K; Hagiwara S; Kitano T
    Blood Purif; 2019; 48(4):358-367. PubMed ID: 31344702
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Effect of Membrane Permeability on Cardiovascular Risk Factors and β2m Plasma Levels in Patients on Long-Term Haemodialysis: A Randomised Crossover Trial.
    Chazot C; Kirchgessner J; Pham J; Vo-Van C; Lorriaux C; Hurot JM; Zaoui E; Grassmann A; Jean G; Marcelli D
    Nephron; 2015; 129(4):269-75. PubMed ID: 25825336
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Removal of uraemic plasma factor(s) using different dialysis modalities reduces phosphatidylserine exposure in red blood cells.
    Bonomini M; Ballone E; Di Stante S; Bucciarelli T; Dottori S; Arduini A; Urbani A; Sirolli V
    Nephrol Dial Transplant; 2004 Jan; 19(1):68-74. PubMed ID: 14671041
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis.
    Krane V; Krieter DH; Olschewski M; März W; Mann JF; Ritz E; Wanner C
    Am J Kidney Dis; 2007 Feb; 49(2):267-75. PubMed ID: 17261429
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Treatment modalities in comparison: when do clinical differences emerge?
    Locatelli F; Manzoni C
    Nephrol Dial Transplant; 2000; 15 Suppl 1():29-35. PubMed ID: 10737164
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The effect of convection on the nutritional status of haemodialysis patients.
    Basile C
    Nephrol Dial Transplant; 2003 Aug; 18 Suppl 7():vii46-9; discussion vii58-9. PubMed ID: 12953030
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Role of C-reactive protein, reticulocyte haemoglobin content and inflammatory markers in iron and erythropoietin administration in dialysis patients.
    El-Khatib M; Duncan HJ; Kant KS
    Nephrology (Carlton); 2006 Oct; 11(5):400-4. PubMed ID: 17014552
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Effect of vitamin E-bonded membrane on the 8-hydroxy 2'-deoxyguanosine level in leukocyte DNA of hemodialysis patients.
    Tarng DC; Huang TP; Liu TY; Chen HW; Sung YJ; Wei YH
    Kidney Int; 2000 Aug; 58(2):790-9. PubMed ID: 10916104
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Serum hepcidin concentration in chronic haemodialysis patients: associations and effects of dialysis, iron and erythropoietin therapy.
    Weiss G; Theurl I; Eder S; Koppelstaetter C; Kurz K; Sonnweber T; Kobold U; Mayer G
    Eur J Clin Invest; 2009 Oct; 39(10):883-90. PubMed ID: 19563467
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.