These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 27050639)

  • 1. Effect of sherbet timing on distension and evaluation of the esophagus with multidetector-row computed tomography.
    Keulers AR; Hundt W; Mahnken AH
    Diagn Interv Imaging; 2016 Jun; 97(6):627-33. PubMed ID: 27050639
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Value of oral effervescent powder administration for multidetector CT evaluation of esophageal cancer.
    Ringe KI; Meyer S; Ringe BP; Winkler M; Wacker F; Raatschen HJ
    Eur J Radiol; 2015 Feb; 84(2):215-20. PubMed ID: 25497235
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Value of two-phase dynamic multidetector computed tomography in differential diagnosis of post-inflammatory strictures from esophageal cancer.
    Karmazanovsky GG; Buryakina SA; Kondratiev EV; Yang Q; Ruchkin DV; Kalinin DV
    World J Gastroenterol; 2015 Aug; 21(29):8878-87. PubMed ID: 26269677
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Value of MDCT in diagnosis and management of esophageal sharp or pointed foreign bodies according to level of esophagus.
    Ma J; Kang DK; Bae JI; Park KJ; Sun JS
    AJR Am J Roentgenol; 2013 Nov; 201(5):W707-11. PubMed ID: 24147500
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Demonstration of the anatomy of the esophageal artery using multidetector-row helical computed tomography.
    Kato T; Takase K; Ichikawa H; Satomi S; Takahashi S
    J Comput Assist Tomogr; 2010; 34(6):939-44. PubMed ID: 21084913
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fish bone foreign bodies in the pharynx and upper esophagus: evaluation with 64-slice MDCT.
    Park S; Choi DS; Shin HS; Cho JM; Jeon KN; Bae KS; Koh EH; Park JJ
    Acta Radiol; 2014 Feb; 55(1):8-13. PubMed ID: 23884842
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multidetector computed tomography of spontaneous versus secondary pneumomediastinum in 89 patients: can multidetector computed tomography be used to reliably distinguish between the 2 entities?
    Ho AS; Ahmed A; Huang JS; Menias CO; Bhalla S
    J Thorac Imaging; 2012 Mar; 27(2):85-92. PubMed ID: 21436744
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endocardial visualization of esophageal-left atrial anatomic relationship by three-dimensional multidetector computed tomography "navigator imaging".
    Wang SL; Ooi CG; Siu CW; Yiu MW; Pang C; Lau CP; Tse HF
    Pacing Clin Electrophysiol; 2006 May; 29(5):502-8. PubMed ID: 16689846
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of two oral contrast materials for CT evaluation of the esophagus.
    Laohawiriyakamol K; Laothamatas J; Chanyongvorakul E
    J Med Assoc Thai; 2007 May; 90(5):903-12. PubMed ID: 17596044
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Demonstration of vascular abnormalities compressing esophagus by MDCT: special focus on dysphagia lusoria.
    Alper F; Akgun M; Kantarci M; Eroglu A; Ceyhan E; Onbas O; Duran C; Okur A
    Eur J Radiol; 2006 Jul; 59(1):82-7. PubMed ID: 16513313
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Usefulness of MDCT evaluation of the intraluminal surface of esophageal masses using only effervescent powder without injection of hypotonic agent.
    Jin GY; Park SH; Han YM
    Abdom Imaging; 2009 Jul; 34(4):424-9. PubMed ID: 18493816
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Esophageal cancer: pneumo-64-MDCT.
    Ulla M; Cavadas D; Muñoz I; Beskow A; Seehaus A; García-Mónaco R
    Abdom Imaging; 2010 Aug; 35(4):383-9. PubMed ID: 19568806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sutureless Aortic Valve Prosthesis Sizing: Estimation and Prediction Using Multidetector-Row Computed Tomography.
    Margaryan R; Kallushi E; Gilmanov D; Micelli A; Murzi M; Solinas M; Cerillo AG; Glauber M
    Innovations (Phila); 2015; 10(4):230-5; discussion 235. PubMed ID: 26371451
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT].
    Harrieder A; Geyer LL; Körner M; Deak Z; Wirth S; Reiser M; Linsenmaier U
    Rofo; 2012 May; 184(5):443-9. PubMed ID: 22297914
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring esophageal distension by high-frequency intraluminal ultrasound probe.
    Rhee PL; Liu J; Puckett JL; Mittal RK
    Am J Physiol Gastrointest Liver Physiol; 2002 Oct; 283(4):G886-92. PubMed ID: 12223348
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic performance of using effervescent powder for detection and grading of esophageal varices by multi-detector computed tomography.
    Cansu A; Ahmetoglu A; Kul S; Yukunc G; Fidan S; Arslan M; Topbas M
    Eur J Radiol; 2014 Mar; 83(3):497-502. PubMed ID: 24355657
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of portosystemic collaterals by MDCT-MPR imaging for management of hemorrhagic esophageal varices.
    Kodama H; Aikata H; Takaki S; Azakami T; Katamura Y; Kawaoka T; Hiramatsu A; Waki K; Imamura M; Kawakami Y; Takahashi S; Toyota N; Ito K; Chayama K
    Eur J Radiol; 2010 Nov; 76(2):239-45. PubMed ID: 19604662
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multidetector CT and virtual endoscopy in the evaluation of the esophagus.
    Mazzeo S; Caramella D; Gennai A; Giusti P; Neri E; Melai L; Cappelli C; Bertini R; Capria A; Rossi M; Bartolozzi C
    Abdom Imaging; 2004; 29(1):2-8. PubMed ID: 15160744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous imaging of esophagogastric junction in patients with reflux esophagitis using 320-row area detector CT: a feasibility study.
    Fukazawa K; Furuta K; Adachi K; Shimura S; Kamiyama K; Aimi M; Ohara S; Kajitani T; Tsurusaki M; Kitagaki H; Kinoshita Y
    J Gastroenterol Hepatol; 2013 Oct; 28(10):1600-7. PubMed ID: 23663082
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Esophageal injuries: spectrum of multidetector row CT findings.
    de Lutio di Castelguidone E; Merola S; Pinto A; Raissaki M; Gagliardi N; Romano L
    Eur J Radiol; 2006 Sep; 59(3):344-8. PubMed ID: 16793233
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.