BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 27051169)

  • 1. Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect.
    Mahdavi H; Jabbari K; Roayaei M
    J Med Phys; 2016; 41(1):38-44. PubMed ID: 27051169
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surface and superficial dose dosimetric verification for postmastectomy radiotherapy.
    Shiau AC; Chiu MC; Chen TH; Chiou JF; Shueng PW; Chen SW; Chen WL; Kuan WP
    Med Dosim; 2012; 37(4):417-24. PubMed ID: 22552120
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical implementation of brass mesh bolus for chest wall postmastectomy radiotherapy and film dosimetry for surface dose estimates.
    Lobo D; Banerjee S; Saxena PU; Ravichandran R; Srinivas C; Putha SK; Kasturi DP
    J Cancer Res Ther; 2019; 15(5):1042-1050. PubMed ID: 31603108
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conformal electron beam radiotherapy using custom-made step bolus for postmastectomy chest wall irradiation: An institutional experience.
    Ananthi B; Bhuvana K; Faith RV; Selvaluxmy G; Vivekanandan N; Priya I
    J Cancer Res Ther; 2019; 15(5):999-1004. PubMed ID: 31603101
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical application of 3D-printed-step-bolus in post-total-mastectomy electron conformal therapy.
    Park K; Park S; Jeon MJ; Choi J; Kim JW; Cho YJ; Jang WS; Keum YS; Lee IJ
    Oncotarget; 2017 Apr; 8(15):25660-25668. PubMed ID: 27784001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A custom three-dimensional electron bolus technique for optimization of postmastectomy irradiation.
    Perkins GH; McNeese MD; Antolak JA; Buchholz TA; Strom EA; Hogstrom KR
    Int J Radiat Oncol Biol Phys; 2001 Nov; 51(4):1142-51. PubMed ID: 11704339
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of bolus electron conformal therapy compared with conventional techniques for the treatment of left chest wall postmastectomy in patients with breast cancer.
    Opp D; Forster K; Li W; Zhang G; Harris EE
    Med Dosim; 2013; 38(4):448-53. PubMed ID: 24200221
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel real-time shapeable soft rubber bolus for clinical use in electron radiotherapy.
    Wakabayashi K; Monzen H; Tamura M; Takei Y; Okuhata K; Anami S; Doi H; Nishimura Y
    Phys Med Biol; 2021 Sep; 66(18):. PubMed ID: 34438390
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric assessment of bolus for postmastectomy radiotherapy.
    Kawamoto T; Shikama N; Kurokawa C; Hara N; Oshima M; Sasai K
    Med Dosim; 2021 Spring; 46(1):e1-e4. PubMed ID: 32891467
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.
    Zhang R; Heins D; Sanders M; Guo B; Hogstrom K
    Med Phys; 2018 Jul; 45(7):2912-2924. PubMed ID: 29749075
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric effects of brass mesh bolus on skin dose and dose at depth for postmastectomy chest wall irradiation.
    Al-Rahbi ZS; Cutajar DL; Metcalfe P; Rosenfeld AB
    Phys Med; 2018 Oct; 54():84-93. PubMed ID: 30337014
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface Dose Measurements in Chest Wall Postmastectomy Radiotherapy to Achieve Optimal Dose Delivery with 6 MV Photon Beam.
    Lobo D; Banerjee S; Srinivas C; Athiyamaan MS; Reddy S; Sunny J; Ravichandran R; Kotian H; Prakash Saxena PU
    J Med Phys; 2021; 46(4):324-333. PubMed ID: 35261503
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of intensity-modulated electron FLASH radiotherapy in a clinical setting using veterinary cases.
    Konradsson E; Szecsenyi RE; Adrian G; Coskun M; Børresen B; Arendt ML; Erhart K; Bäck SÅ; Petersson K; Ceberg C
    Med Phys; 2023 Oct; 50(10):6569-6579. PubMed ID: 37696040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characteristics of a bolus created using thermoplastic sheets for postmastectomy radiation therapy.
    Sakai Y; Tanooka M; Okada W; Sano K; Nakamura K; Shibata M; Ueda Y; Mizuno H; Tanaka M
    Radiol Phys Technol; 2021 Jun; 14(2):179-185. PubMed ID: 33837911
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric Evaluation of Commercially Available Flat vs. Self-Produced 3D-Conformal Silicone Boluses for the Head and Neck Region.
    Pollmann S; Toussaint A; Flentje M; Wegener S; Lewitzki V
    Front Oncol; 2022; 12():881439. PubMed ID: 36033533
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.
    Yoon J; Xie Y; Zhang R
    J Appl Clin Med Phys; 2018 Mar; 19(2):137-143. PubMed ID: 29427312
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and production of 3D printed bolus for electron radiation therapy.
    Su S; Moran K; Robar JL
    J Appl Clin Med Phys; 2014 Jul; 15(4):4831. PubMed ID: 25207410
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Technical note: Evaluation of a silicone-based custom bolus for radiation therapy of a superficial pelvic tumor.
    Wang KM; Rickards AJ; Bingham T; Tward JD; Price RG
    J Appl Clin Med Phys; 2022 Apr; 23(4):e13538. PubMed ID: 35084098
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Feasibility of Customized Thermoplastic Patient-Specific Helmet Bolus for Scalp Irradiation Using Volumetric-Modulated Arc Therapy Planning.
    Kim H; Lee JW; Hong S
    Technol Cancer Res Treat; 2024; 23():15330338241241898. PubMed ID: 38557213
    [No Abstract]   [Full Text] [Related]  

  • 20. Post-mastectomy radiotherapy: Impact of bolus thickness and irradiation technique on skin dose.
    Miéville FA; Pitteloud N; Achard V; Lamanna G; Pisaturo O; Tercier PA; Allal AS
    Z Med Phys; 2023 May; ():. PubMed ID: 37150728
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.