BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 27055766)

  • 1. Analysis of non-Newtonian effects on Low-Density Lipoprotein accumulation in an artery.
    Iasiello M; Vafai K; Andreozzi A; Bianco N
    J Biomech; 2016 Jun; 49(9):1437-1446. PubMed ID: 27055766
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low-density lipoprotein accumulation within a carotid artery with multilayer elastic porous wall: fluid-structure interaction and non-Newtonian considerations.
    Deyranlou A; Niazmand H; Sadeghi MR
    J Biomech; 2015 Sep; 48(12):2948-59. PubMed ID: 26300402
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of non-Newtonian effects within an aorta-iliac bifurcation region.
    Iasiello M; Vafai K; Andreozzi A; Bianco N
    J Biomech; 2017 Nov; 64():153-163. PubMed ID: 29100596
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of non-Newtonian fluid rheology on an arterial bypass graft: A numerical investigation guided by constructal design.
    Dutra RF; Zinani FSF; Rocha LAO; Biserni C
    Comput Methods Programs Biomed; 2021 Apr; 201():105944. PubMed ID: 33535083
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Boundary layer considerations in a multi-layer model for LDL accumulation.
    Iasiello M; Vafai K; Andreozzi A; Bianco N
    Comput Methods Biomech Biomed Engin; 2018 Nov; 21(15):803-811. PubMed ID: 30398068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fluid-wall modelling of mass transfer in an axisymmetric stenosis: effects of shear-dependent transport properties.
    Sun N; Wood NB; Hughes AD; Thom SA; Xu XY
    Ann Biomed Eng; 2006 Jul; 34(7):1119-28. PubMed ID: 16791491
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modelling and simulation of low-density lipoprotein transport through multi-layered wall of an anatomically realistic carotid artery bifurcation.
    Kenjereš S; de Loor A
    J R Soc Interface; 2014 Feb; 11(91):20130941. PubMed ID: 24284897
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multiphysics simulation of blood flow and LDL transport in a porohyperelastic arterial wall model.
    Koshiba N; Ando J; Chen X; Hisada T
    J Biomech Eng; 2007 Jun; 129(3):374-85. PubMed ID: 17536904
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rheological effects of blood in a nonplanar distal end-to-side anastomosis.
    Wang QQ; Ping BH; Xu QB; Wang W
    J Biomech Eng; 2008 Oct; 130(5):051009. PubMed ID: 19045516
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical investigation of the non-Newtonian blood flow in a bifurcation model with a non-planar branch.
    Chen J; Lu XY
    J Biomech; 2004 Dec; 37(12):1899-911. PubMed ID: 15519598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational analysis of coupled blood-wall arterial LDL transport.
    Stangeby DK; Ethier CR
    J Biomech Eng; 2002 Feb; 124(1):1-8. PubMed ID: 11871594
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simulation of LDL permeation into multilayer wall of a coronary bifurcation using WSS-dependent model: effects of hemorheology.
    Moniripiri M; Hassani Soukht Abandani M; Firoozabadi B
    Biomech Model Mechanobiol; 2023 Apr; 22(2):711-727. PubMed ID: 36525181
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computational modeling of LDL and albumin transport in an in vivo CT image-based human right coronary artery.
    Sun N; Torii R; Wood NB; Hughes AD; Thom SA; Xu XY
    J Biomech Eng; 2009 Feb; 131(2):021003. PubMed ID: 19102562
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Low-density lipoprotein transport through an arterial wall under hyperthermia and hypertension conditions--An analytical solution.
    Iasiello M; Vafai K; Andreozzi A; Bianco N
    J Biomech; 2016 Jan; 49(2):193-204. PubMed ID: 26806687
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Finite element computation of magneto-hemodynamic flow and heat transfer in a bifurcated artery with saccular aneurysm using the Carreau-Yasuda biorheological model.
    Dubey A; B V; Bég OA; Gorla RSR
    Microvasc Res; 2021 Nov; 138():104221. PubMed ID: 34271062
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low density lipoprotein transport through patient-specific thoracic arterial wall.
    Mpairaktaris DG; Soulis JV; Giannoglou GD
    Comput Biol Med; 2017 Oct; 89():115-126. PubMed ID: 28800440
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Numerical simulation of low-density lipoprotein mass transport in human arterial stenosis - Calculation of the filtration velocity.
    Karami F; Hossainpour S; Ghalichi F
    Biomed Mater Eng; 2018; 29(1):95-108. PubMed ID: 29254076
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modelling blood flow in coronary arteries: Newtonian or shear-thinning non-Newtonian rheology?
    De Nisco G; Lodi Rizzini M; Verardi R; Chiastra C; Candreva A; De Ferrari G; D'Ascenzo F; Gallo D; Morbiducci U
    Comput Methods Programs Biomed; 2023 Dec; 242():107823. PubMed ID: 37757568
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of flow and LDL concentration polarization in siphon of internal carotid artery: Non-Newtonian effects.
    Sharifi A; Niazmand H
    Comput Biol Med; 2015 Oct; 65():93-102. PubMed ID: 26313530
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of non-Newtonian and pulsatile blood flow on mass transport in the human aorta.
    Liu X; Fan Y; Deng X; Zhan F
    J Biomech; 2011 Apr; 44(6):1123-31. PubMed ID: 21310418
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.