BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 27056278)

  • 21. Minimally Invasive Intramedullary Screw Versus Plate Fixation for Proximal Phalanx Fractures: A Biomechanical Study.
    Miles MR; Krul KP; Abbasi P; Thakkar MY; Giladi AM; Means KR
    J Hand Surg Am; 2021 Jun; 46(6):518.e1-518.e8. PubMed ID: 33423850
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A Comparative Study of Tensile Strength of Three Operative Fixation Techniques for Metacarpal Shaft Fractures in Adults: A Cadaver Study.
    Oh JR; Kim DS; Yeom JS; Kang SK; Kim YT
    Clin Orthop Surg; 2019 Mar; 11(1):120-125. PubMed ID: 30838116
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Headless Compression Screw Versus Kirschner Wire Fixation for Metacarpal Neck Fractures: A Biomechanical Study.
    Avery DM; Klinge S; Dyrna F; Pauzenberger L; Lam D; Cote M; DiVenere J; Obopilwe E; Mazzocca A; Rodner C
    J Hand Surg Am; 2017 May; 42(5):392.e1-392.e6. PubMed ID: 28359640
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fixation strength of anteriorly inserted headless screws for talar neck fractures.
    Capelle JH; Couch CG; Wells KM; Morris RP; Buford WL; Merriman DJ; Panchbhavi VK
    Foot Ankle Int; 2013 Jul; 34(7):1012-6. PubMed ID: 23456083
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Translated article] Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study.
    Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I
    Rev Esp Cir Ortop Traumatol; 2023; 67(1):T50-T55. PubMed ID: 36243394
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study.
    Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I
    Rev Esp Cir Ortop Traumatol; 2023; 67(1):50-55. PubMed ID: 35709951
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Volar Anatomy of the Proximal Phalanx: Implications for Screw Length Selection for Fixation of Shaft Fractures.
    Honeycutt PB; Jernigan EW; Rummings WA; Stern PJ; Draeger RW
    J Hand Surg Am; 2017 Mar; 42(3):e149-e157. PubMed ID: 28259279
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Percutaneous headless screws and wide-awake anesthesia to fix metacarpal and phalangeal fractures: outcomes of the first 56 cases.
    Nucci AM; Del Chiaro A; Addevico F; Raspanti A; Poggetti A
    J Biol Regul Homeost Agents; 2018; 32(6):1569-1572. PubMed ID: 30574766
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Outcomes of 173 metacarpal and phalangeal fractures treated by intramedullary headless screw fixation with a 4-year follow-up.
    Poggetti A; Fagetti A; Lauri G; Cherubino M; Borelli PP; Pfanner S
    J Hand Surg Eur Vol; 2021 Jun; 46(5):466-470. PubMed ID: 33444072
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Retrograde fixation of metacarpal fractures with intramedullary cannulated headless compression screws.
    Jann D; Calcagni M; Giovanoli P; Giesen T
    Hand Surg Rehabil; 2018 Apr; 37(2):99-103. PubMed ID: 29503183
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intramedullary Percutaneous Fixation of Extra-Articular Proximal and Middle Phalanx Fractures.
    Jovanovic N; Aldlyami E; Saraj B; Fm Seidam M; Badawi H; Shaat A; Alawadi K; Dodakundi C
    Tech Hand Up Extrem Surg; 2018 Jun; 22(2):51-56. PubMed ID: 29505436
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy in Screw Selection in a Cadaveric, Small-Bone Fracture Model.
    Jernigan EW; Honeycutt PB; Patterson JMM; Rummings WA; Bynum DK; Draeger RW
    J Hand Surg Am; 2018 Dec; 43(12):1138.e1-1138.e8. PubMed ID: 29801935
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical outcomes of limited-open retrograde intramedullary headless screw fixation of metacarpal fractures.
    Ruchelsman DE; Puri S; Feinberg-Zadek N; Leibman MI; Belsky MR
    J Hand Surg Am; 2014 Dec; 39(12):2390-5. PubMed ID: 25240434
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Intramedullary Fixation of Hand Fractures and Arthrodeses.
    Hassan K; Blumenthal S; Jehle CC; Sobel AD
    J Hand Surg Am; 2024 Jan; 49(1):42-49. PubMed ID: 37777934
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Intramedullary Headless Screw Fixation for Metacarpal Fractures.
    Sellers TR; Lewis JT; Smith C; Nydick JA
    Tech Hand Up Extrem Surg; 2020 Jun; 25(1):45-51. PubMed ID: 32520776
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An Anatomical Study of Metacarpal Morphology Utilizing CT Scans: Evaluating Parameters for Antegrade Intramedullary Compression Screw Fixation of Metacarpal Fractures.
    Hoang D; Vu CL; Jackson M; Huang JI
    J Hand Surg Am; 2021 Feb; 46(2):149.e1-149.e8. PubMed ID: 33092908
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Morphological Analysis of Metacarpal Shafts With Respect to Retrograde Intramedullary Headless Screw Fixation.
    Dunleavy ML; Candela X; Darowish M
    Hand (N Y); 2022 Jul; 17(4):602-608. PubMed ID: 32666845
    [No Abstract]   [Full Text] [Related]  

  • 38. Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation.
    Hapa O; Karakaşlı A; Dinçer C; Zhamilov V; Güvencer M; Havitçioğlu H
    Acta Orthop Traumatol Turc; 2015; 49(3):307-10. PubMed ID: 26200411
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Articular Surface Involvement With Retrograde Headless Screw Fixation of the Proximal Phalanx.
    Martin S; Murray EP; Mitchell A; Beucler W; Ablove R
    J Hand Surg Am; 2023 Dec; ():. PubMed ID: 38085192
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intramedullary compression screw fixation of metacarpal and phalangeal fractures.
    Guidi M; Frueh FS; Besmens I; Calcagni M
    EFORT Open Rev; 2020 Oct; 5(10):624-629. PubMed ID: 33204505
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.