231 related articles for article (PubMed ID: 27056278)
21. Minimally Invasive Intramedullary Screw Versus Plate Fixation for Proximal Phalanx Fractures: A Biomechanical Study.
Miles MR; Krul KP; Abbasi P; Thakkar MY; Giladi AM; Means KR
J Hand Surg Am; 2021 Jun; 46(6):518.e1-518.e8. PubMed ID: 33423850
[TBL] [Abstract][Full Text] [Related]
22. A Comparative Study of Tensile Strength of Three Operative Fixation Techniques for Metacarpal Shaft Fractures in Adults: A Cadaver Study.
Oh JR; Kim DS; Yeom JS; Kang SK; Kim YT
Clin Orthop Surg; 2019 Mar; 11(1):120-125. PubMed ID: 30838116
[TBL] [Abstract][Full Text] [Related]
23. Headless Compression Screw Versus Kirschner Wire Fixation for Metacarpal Neck Fractures: A Biomechanical Study.
Avery DM; Klinge S; Dyrna F; Pauzenberger L; Lam D; Cote M; DiVenere J; Obopilwe E; Mazzocca A; Rodner C
J Hand Surg Am; 2017 May; 42(5):392.e1-392.e6. PubMed ID: 28359640
[TBL] [Abstract][Full Text] [Related]
24. Fixation strength of anteriorly inserted headless screws for talar neck fractures.
Capelle JH; Couch CG; Wells KM; Morris RP; Buford WL; Merriman DJ; Panchbhavi VK
Foot Ankle Int; 2013 Jul; 34(7):1012-6. PubMed ID: 23456083
[TBL] [Abstract][Full Text] [Related]
25. [Translated article] Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study.
Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I
Rev Esp Cir Ortop Traumatol; 2023; 67(1):T50-T55. PubMed ID: 36243394
[TBL] [Abstract][Full Text] [Related]
26. Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study.
Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I
Rev Esp Cir Ortop Traumatol; 2023; 67(1):50-55. PubMed ID: 35709951
[TBL] [Abstract][Full Text] [Related]
27. Volar Anatomy of the Proximal Phalanx: Implications for Screw Length Selection for Fixation of Shaft Fractures.
Honeycutt PB; Jernigan EW; Rummings WA; Stern PJ; Draeger RW
J Hand Surg Am; 2017 Mar; 42(3):e149-e157. PubMed ID: 28259279
[TBL] [Abstract][Full Text] [Related]
28. Percutaneous headless screws and wide-awake anesthesia to fix metacarpal and phalangeal fractures: outcomes of the first 56 cases.
Nucci AM; Del Chiaro A; Addevico F; Raspanti A; Poggetti A
J Biol Regul Homeost Agents; 2018; 32(6):1569-1572. PubMed ID: 30574766
[TBL] [Abstract][Full Text] [Related]
29. Outcomes of 173 metacarpal and phalangeal fractures treated by intramedullary headless screw fixation with a 4-year follow-up.
Poggetti A; Fagetti A; Lauri G; Cherubino M; Borelli PP; Pfanner S
J Hand Surg Eur Vol; 2021 Jun; 46(5):466-470. PubMed ID: 33444072
[TBL] [Abstract][Full Text] [Related]
30. Retrograde fixation of metacarpal fractures with intramedullary cannulated headless compression screws.
Jann D; Calcagni M; Giovanoli P; Giesen T
Hand Surg Rehabil; 2018 Apr; 37(2):99-103. PubMed ID: 29503183
[TBL] [Abstract][Full Text] [Related]
31. Intramedullary Percutaneous Fixation of Extra-Articular Proximal and Middle Phalanx Fractures.
Jovanovic N; Aldlyami E; Saraj B; Fm Seidam M; Badawi H; Shaat A; Alawadi K; Dodakundi C
Tech Hand Up Extrem Surg; 2018 Jun; 22(2):51-56. PubMed ID: 29505436
[TBL] [Abstract][Full Text] [Related]
32. Accuracy in Screw Selection in a Cadaveric, Small-Bone Fracture Model.
Jernigan EW; Honeycutt PB; Patterson JMM; Rummings WA; Bynum DK; Draeger RW
J Hand Surg Am; 2018 Dec; 43(12):1138.e1-1138.e8. PubMed ID: 29801935
[TBL] [Abstract][Full Text] [Related]
33. Clinical outcomes of limited-open retrograde intramedullary headless screw fixation of metacarpal fractures.
Ruchelsman DE; Puri S; Feinberg-Zadek N; Leibman MI; Belsky MR
J Hand Surg Am; 2014 Dec; 39(12):2390-5. PubMed ID: 25240434
[TBL] [Abstract][Full Text] [Related]
34. Intramedullary Fixation of Hand Fractures and Arthrodeses.
Hassan K; Blumenthal S; Jehle CC; Sobel AD
J Hand Surg Am; 2024 Jan; 49(1):42-49. PubMed ID: 37777934
[TBL] [Abstract][Full Text] [Related]
35. Intramedullary Headless Screw Fixation for Metacarpal Fractures.
Sellers TR; Lewis JT; Smith C; Nydick JA
Tech Hand Up Extrem Surg; 2020 Jun; 25(1):45-51. PubMed ID: 32520776
[TBL] [Abstract][Full Text] [Related]
36. An Anatomical Study of Metacarpal Morphology Utilizing CT Scans: Evaluating Parameters for Antegrade Intramedullary Compression Screw Fixation of Metacarpal Fractures.
Hoang D; Vu CL; Jackson M; Huang JI
J Hand Surg Am; 2021 Feb; 46(2):149.e1-149.e8. PubMed ID: 33092908
[TBL] [Abstract][Full Text] [Related]
37. Morphological Analysis of Metacarpal Shafts With Respect to Retrograde Intramedullary Headless Screw Fixation.
Dunleavy ML; Candela X; Darowish M
Hand (N Y); 2022 Jul; 17(4):602-608. PubMed ID: 32666845
[No Abstract] [Full Text] [Related]
38. Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation.
Hapa O; Karakaşlı A; Dinçer C; Zhamilov V; Güvencer M; Havitçioğlu H
Acta Orthop Traumatol Turc; 2015; 49(3):307-10. PubMed ID: 26200411
[TBL] [Abstract][Full Text] [Related]
39. Articular Surface Involvement With Retrograde Headless Screw Fixation of the Proximal Phalanx.
Martin S; Murray EP; Mitchell A; Beucler W; Ablove R
J Hand Surg Am; 2023 Dec; ():. PubMed ID: 38085192
[TBL] [Abstract][Full Text] [Related]
40. Intramedullary compression screw fixation of metacarpal and phalangeal fractures.
Guidi M; Frueh FS; Besmens I; Calcagni M
EFORT Open Rev; 2020 Oct; 5(10):624-629. PubMed ID: 33204505
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]