BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

723 related articles for article (PubMed ID: 27056309)

  • 1. Pre-Procedural Hemodynamic Status Improves the Discriminatory Value of the Aortic Regurgitation Index in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Sinning JM; Stundl A; Pingel S; Weber M; Sedaghat A; Hammerstingl C; Vasa-Nicotera M; Mellert F; Schiller W; Kovac J; Welz A; Grube E; Werner N; Nickenig G
    JACC Cardiovasc Interv; 2016 Apr; 9(7):700-11. PubMed ID: 27056309
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (placement of aortic transcatheter valve).
    Hahn RT; Pibarot P; Webb J; Rodes-Cabau J; Herrmann HC; Williams M; Makkar R; Szeto WY; Main ML; Thourani VH; Tuzcu EM; Kapadia S; Akin J; McAndrew T; Xu K; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2014 Jul; 7(7):781-9. PubMed ID: 25060022
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical impact of aortic regurgitation after transcatheter aortic valve replacement: insights into the degree and acuteness of presentation.
    Jerez-Valero M; Urena M; Webb JG; Tamburino C; Munoz-Garcia AJ; Cheema A; Dager AE; Serra V; Amat-Santos IJ; Barbanti M; Immè S; Alonso Briales JH; Al Lawati H; Benitez LM; Cucalon AM; Garcia del Blanco B; Revilla A; Dumont E; Barbosa Ribeiro H; Nombela-Franco L; Bergeron S; Pibarot P; Rodés-Cabau J
    JACC Cardiovasc Interv; 2014 Sep; 7(9):1022-32. PubMed ID: 25234675
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prognostic Importance of Diastolic Dysfunction in Relation to Post Procedural Aortic Insufficiency in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Kampaktsis PN; Bang CN; Chiu Wong S; Skubas NJ; Singh H; Voudris K; Baduashvili A; Pastella K; Swaminathan RV; Kaple RK; Minutello RM; Feldman DN; Kim L; Hriljac I; Lin F; Bergman GS; Salemi A; Devereux RB
    Catheter Cardiovasc Interv; 2017 Feb; 89(3):445-451. PubMed ID: 27218599
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Management of paravalvular regurgitation after Edwards SAPIEN transcatheter aortic valve replacement: management of paravalvular regurgitation after TAVR.
    Martinez CA; Singh V; O'Neill BP; Alfonso CE; Bilsker MS; Martinez Clark P; Williams D; Cohen MG; Heldman AW; O'Neill WW
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):300-11. PubMed ID: 23580318
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of Post-Procedural Aortic Regurgitation After TAVR: An Intraprocedural TEE Study.
    Mihara H; Shibayama K; Jilaihawi H; Itabashi Y; Berdejo J; Utsunomiya H; Siegel RJ; Makkar RR; Shiota T
    JACC Cardiovasc Imaging; 2015 Sep; 8(9):993-1003. PubMed ID: 26319501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The aortic valve calcium nodule score (AVCNS) independently predicts paravalvular regurgitation after transcatheter aortic valve replacement (TAVR).
    Azzalini L; Ghoshhajra BB; Elmariah S; Passeri JJ; Inglessis I; Palacios IF; Abbara S
    J Cardiovasc Comput Tomogr; 2014; 8(2):131-40. PubMed ID: 24661826
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis.
    Kamperidis V; van Rosendael PJ; de Weger A; Katsanos S; Regeer M; van der Kley F; Mertens B; Sianos G; Ajmone Marsan N; Bax JJ; Delgado V
    JACC Cardiovasc Interv; 2015 Apr; 8(5):670-7. PubMed ID: 25946438
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term outcomes of percutaneous paravalvular regurgitation closure after transcatheter aortic valve replacement: a multicenter experience.
    Saia F; Martinez C; Gafoor S; Singh V; Ciuca C; Hofmann I; Marrozzini C; Tan J; Webb J; Sievert H; Marzocchi A; O'Neill WW
    JACC Cardiovasc Interv; 2015 Apr; 8(5):681-8. PubMed ID: 25946440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Heart-rate adjustment of transcatheter haemodynamics improves the prognostic evaluation of paravalvular regurgitation after transcatheter aortic valve implantation.
    Jilaihawi H; Chakravarty T; Shiota T; Rafique A; Harada K; Shibayama K; Doctor N; Kashif M; Nakamura M; Mirocha J; Rami T; Okuyama K; Cheng W; Sadruddin O; Siegel R; Makkar RR
    EuroIntervention; 2015 Aug; 11(4):456-64. PubMed ID: 25499834
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 3D Assessment of Features Associated With Transvalvular Aortic Regurgitation After TAVR: A Real-Time 3D TEE Study.
    Shibayama K; Mihara H; Jilaihawi H; Berdejo J; Harada K; Itabashi Y; Siegel R; Makkar RR; Shiota T
    JACC Cardiovasc Imaging; 2016 Feb; 9(2):114-23. PubMed ID: 26777225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Valvular performance and aortic regurgitation following transcatheter aortic valve replacement using Edwards valve versus CoreValve for severe aortic stenosis: A Meta-analysis.
    Bhatheja S; Panchal HB; Barry N; Mukherjee D; Uretsky BF; Paul T
    Cardiovasc Revasc Med; 2016 Jun; 17(4):248-55. PubMed ID: 26948087
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical outcome and paravalvular leakage of the new balloon-expandable Edwards Sapien 3 valve in comparison to its predecessor model (Edwards Sapien XT) in patients undergoing transfemoral aortic valve replacement.
    Bocksch W; Grossmann B; Geisler T; Steeg M; Droppa M; Jorbenadze R; Haap M; Gawaz M; Fateh-Moghadam S
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):466-75. PubMed ID: 27184353
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated 3D analysis of pre-procedural MDCT to predict annulus plane angulation and C-arm positioning: benefit on procedural outcome in patients referred for TAVR.
    Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Budde RP; Sieswerda G; Algeri E; van Belle C; Elkalioubie A; Juthier F; Belkacemi A; Bertrand ME; Doevendans PA; Van Belle E
    JACC Cardiovasc Imaging; 2013 Feb; 6(2):238-48. PubMed ID: 23489538
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcatheter valve-in-valve implantation for failed balloon-expandable transcatheter aortic valves.
    Toggweiler S; Wood DA; Rodés-Cabau J; Kapadia S; Willson AB; Ye J; Cheung A; Leipsic J; Binder RK; Gurvitch R; Freeman M; Thompson CR; Svensson LG; Dumont E; Tuzcu EM; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):571-577. PubMed ID: 22625197
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality.
    Schoechlin S; Brennemann T; Allali A; Ruile P; Jander N; Allgeier M; Gick M; Richardt G; Neumann FJ; Abdel-Wahab M
    Catheter Cardiovasc Interv; 2018 May; 91(6):E56-E63. PubMed ID: 29105984
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relative amplitude index: a new tool for hemodynamic evaluation of periprosthetic regurgitation after transcatheter valve implantation.
    Heinz A; DeCillia M; Feuchtner G; Mueller S; Bartel T; Friedrich G; Grimm M; Mueller LCh; Bonaros N
    J Thorac Cardiovasc Surg; 2014 Mar; 147(3):1021-8, 1029.e1-2. PubMed ID: 24342900
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction.
    Little SH; Oh JK; Gillam L; Sengupta PP; Orsinelli DA; Cavalcante JL; Chang JD; Adams DH; Zorn GL; Pollak AW; Abdelmoneim SS; Reardon MJ; Qiao H; Popma JJ
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27313280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.
    Patsalis PC; Al-Rashid F; Neumann T; Plicht B; Hildebrandt HA; Wendt D; Thielmann M; Jakob HG; Heusch G; Erbel R; Kahlert P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):965-71. PubMed ID: 24050862
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 37.