BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 2705888)

  • 1. The realization of a pulsatile implantable impeller pump with low hemolysis.
    Qian KX; Fei Q; Lin KD; Pi KD; Wang YP
    Artif Organs; 1989 Apr; 13(2):162-9. PubMed ID: 2705888
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Low haemolysis pulsatile impeller pump: design concepts and experimental results.
    Qian KX
    J Biomed Eng; 1989 Nov; 11(6):478-81. PubMed ID: 2811347
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart.
    Qian KX
    Med Eng Phys; 1996 Jan; 18(1):57-66. PubMed ID: 8771040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. How to produce a pulsatile flow with low haemolysis?
    Qian KX; Zeng P; Ru WM; Yuan HY; Feng ZG; Li I
    J Med Eng Technol; 2000; 24(5):227-9. PubMed ID: 11204246
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulsatile blood flow from impeller pump: a dream has come true.
    Qian KX
    J Biomater Appl; 1994 Oct; 9(2):158-77. PubMed ID: 7782998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Haemolysis test of non-pulsatile and pulsatile impeller blood pumps.
    Qian KX; Fei Q
    Clin Phys Physiol Meas; 1988 May; 9(2):107-12. PubMed ID: 3391012
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Pulsatile rotary pumps with low hemolysis].
    Qian K; Zeng P; Ru W; Yuan H; Feng Z; Li L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Sep; 18(3):391-3. PubMed ID: 11605497
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experience in reducing the hemolysis of an impeller assist heart.
    Qian KX
    ASAIO Trans; 1989; 35(1):46-53. PubMed ID: 2730808
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Haematological variations in pigs during experimental left ventricular assistance with a pulsatile impeller pump.
    Qian KX; Wang SS; Chu SH
    Med Eng Phys; 1994 Jul; 16(4):348-50. PubMed ID: 7952672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New investigations of a pulsatile impeller blood pump.
    Qian KX
    ASAIO Trans; 1990; 36(1):33-5. PubMed ID: 2306388
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Effect of impeller vane number and angles on pump hemolysis].
    Qian K; Feng Z; Zeng P; Ru W; Yuan H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):605-7. PubMed ID: 14716856
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Streamlined design of impeller and its effect on pump haemolysis.
    Qian KX; Zeng P; Ru WM; Yuan HY
    J Med Eng Technol; 2002; 26(2):79-81. PubMed ID: 12102327
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fluid dynamic characteristics of monopivot magnetic suspension blood pumps.
    Yamane T; Nishida M; Asztalos B; Tsutsui T; Jikuya T
    ASAIO J; 1997; 43(5):M635-8. PubMed ID: 9360122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The helical flow pump with a hydrodynamic levitation impeller.
    Abe Y; Ishii K; Isoyama T; Saito I; Inoue Y; Ono T; Nakagawa H; Nakano E; Fukazawa K; Ishihara K; Fukunaga K; Ono M; Imachi K
    J Artif Organs; 2012 Dec; 15(4):331-40. PubMed ID: 22926404
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results.
    Mizuguchi K; Damm GA; Bozeman RJ; Akkerman JW; Aber GS; Svejkovsky PA; Bacak JW; Orime Y; Takatani S; Nosé Y
    Artif Organs; 1994 Jan; 18(1):32-43. PubMed ID: 8141655
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump (TinyPump).
    Kido K; Hoshi H; Watanabe N; Kataoka H; Ohuchi K; Asama J; Shinshi T; Yoshikawa M; Takatani S
    Artif Organs; 2006 May; 30(5):392-9. PubMed ID: 16683958
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device.
    Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S
    Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Haemodynamic approach to reducing thrombosis and haemolysis in an impeller pump.
    Qian KX
    J Biomed Eng; 1990 Nov; 12(6):533-5. PubMed ID: 2266752
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The hemolysis test of the Gyro C1E3 pump in pulsatile mode.
    Tayama E; Nakazawa T; Takami Y; Makinouchi K; Ohtsubo S; Ohashi Y; Andrade AJ; Glueck J; Mueller J; Nosé Y
    Artif Organs; 1997 Jul; 21(7):675-9. PubMed ID: 9304391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impeller design for a miniaturized centrifugal blood pump.
    Takano T; Schulte-Eistrup S; Yoshikawa M; Nakata K; Kawahito S; Maeda T; Nonaka K; Linneweber J; Glueck J; Fujisawa A; Makinouchi K; Yokokawa M; Nosé Y
    Artif Organs; 2000 Oct; 24(10):821-5. PubMed ID: 11091172
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.