BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 27060127)

  • 1. Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.
    Reinhardt S; Martin H; Ulmar B; Döbele S; Zwipp H; Rammelt S; Richter M; Pompach M; Mittlmeier T
    Foot Ankle Int; 2016 Aug; 37(8):891-7. PubMed ID: 27060127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
    Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
    Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
    [TBL] [Abstract][Full Text] [Related]  

  • 3. C-Nail versus plate osteosynthesis in displaced intra-articular calcaneal fractures-a comparative retrospective study.
    Steinhausen E; Martin W; Lefering R; Lundin S; Glombitza M; Mester B; Brinkmann N; Dudda M
    J Orthop Surg Res; 2021 Mar; 16(1):203. PubMed ID: 33743770
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical Performance of Lateral Versus Dual Locking Plates for Calcaneal Fractures.
    Maxwell AB; Owen JR; Gilbert TM; Romash MM; Wayne JS; Adelaar RS
    J Foot Ankle Surg; 2015; 54(5):830-5. PubMed ID: 25960057
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calcaneal fracture fixation using a new interlocking nail reduces complications compared to standard locking plates - Preliminary results after 1.6 years.
    Herlyn A; Brakelmann A; Herlyn PK; Gradl G; Mittlmeier T
    Injury; 2019 Aug; 50 Suppl 3():63-68. PubMed ID: 31378540
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comminuted intraarticular calcaneal fractures: Multiplanar VA locked plating and interlocked nailing incorporate longitudinal strut and provide superior stability - a biomechanical cadaveric study.
    Stefanov A; Ivanov S; Zderic I; Baltov A; Rashkov M; Gehweiler D; Richards G; Gueorguiev B; Enchev D
    Injury; 2022 Oct; 53(10):3543-3552. PubMed ID: 35810043
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].
    Zeman P; Zeman J; Matejka J; Koudela K
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):457-64. PubMed ID: 19150004
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
    Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
    Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparisons in finite element analysis of minimally invasive, locking, and non-locking plates systems used in treating calcaneal fractures of Sanders type II and type III.
    He K; Fu S; Liu S; Wang Z; Jin D
    Chin Med J (Engl); 2014; 127(22):3894-901. PubMed ID: 25421187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical Comparison of Conventional Plate and the C-Nail
    Pînzaru RM; Pavăl SD; Perțea M; Alexa O; Sîrbu PD; Filip A; Carp AC; Savin L; Forna N; Veliceasa B
    J Pers Med; 2023 Mar; 13(4):. PubMed ID: 37108973
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
    Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
    Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Introduction of a New Locking Nail for Treatment of Intraarticular Calcaneal Fractures.
    Zwipp H; Paša L; Žilka L; Amlang M; Rammelt S; Pompach M
    J Orthop Trauma; 2016 Mar; 30(3):e88-92. PubMed ID: 26901539
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A biomechanical comparison of locking and nonlocking plates for the fixation of calcaneal fractures.
    Redfern DJ; Oliveira ML; Campbell JT; Belkoff SM
    Foot Ankle Int; 2006 Mar; 27(3):196-201. PubMed ID: 16539902
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive internal fixation of calcaneal fractures or subtalar joint arthrodesis using the Calcanail®.
    Saß M; Rotter R; Mittlmeier T
    Oper Orthop Traumatol; 2019 Apr; 31(2):149-164. PubMed ID: 30413845
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical comparison of modified Calcanail system with plating fixation in intra-articular calcaneal fracture: A finite element analysis.
    Ni M; Wong DW; Niu W; Wang Y; Mei J; Zhang M
    Med Eng Phys; 2019 Aug; 70():55-61. PubMed ID: 31229383
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stability of locking and non-locking plates in an osteoporotic calcaneal fracture model.
    Illert T; Rammelt S; Drewes T; Grass R; Zwipp H
    Foot Ankle Int; 2011 Mar; 32(3):307-13. PubMed ID: 21477551
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Open reduction and internal fixation with conventional plate via L-shaped lateral approach versus internal fixation with percutaneous plate via a sinus tarsi approach for calcaneal fractures - a randomized controlled trial.
    Xia S; Lu Y; Wang H; Wu Z; Wang Z
    Int J Surg; 2014; 12(5):475-80. PubMed ID: 24607889
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Limited versus Extended Lateral Approach for Osteosynthesis of Calcaneal Fractures - Comparison of Temporal and Dynamic Parameters of the Gait Cycle].
    Jandová S; Pazour J
    Acta Chir Orthop Traumatol Cech; 2018; 85(1):57-61. PubMed ID: 30257771
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.