178 related articles for article (PubMed ID: 27061632)
1. Effect of plasma nitriding and titanium nitride coating on the corrosion resistance of titanium.
Wang X; Bai S; Li F; Li D; Zhang J; Tian M; Zhang Q; Tong Y; Zhang Z; Wang G; Guo T; Ma C
J Prosthet Dent; 2016 Sep; 116(3):450-6. PubMed ID: 27061632
[TBL] [Abstract][Full Text] [Related]
2. [Corrosion resistance of casted titanium by compound treatments in the artificial saliva with different fluoride concentrations].
Wang XL; Guo TW
Zhonghua Kou Qiang Yi Xue Za Zhi; 2012 Sep; 47(9):557-61. PubMed ID: 23141732
[TBL] [Abstract][Full Text] [Related]
3. [Stress and electrochemical corrosion of titanium produced by laser rapid forming].
Zhu JF; Gan K; Du TF; Gao B
Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Apr; 54(4):257-262. PubMed ID: 30955298
[No Abstract] [Full Text] [Related]
4. [Corrosion resistance and wear resistance of Ni-Cr alloy after coating titanium nitride (TiN) in oral containing fluorine environment].
Weng WM; Yu WQ; Shan WL; Zhang FQ
Shanghai Kou Qiang Yi Xue; 2010 Dec; 19(6):621-5. PubMed ID: 21431263
[TBL] [Abstract][Full Text] [Related]
5. [Influence of TiN, TiCN coating on corrosion resistance of dental pure titanium].
DU JJ; Yu WQ; Wang DL
Shanghai Kou Qiang Yi Xue; 2011 Aug; 20(4):385-9. PubMed ID: 21909603
[TBL] [Abstract][Full Text] [Related]
6. [Experimental study on the corrosion behavior of a type of oral near β-type titanium alloys modified with double glow plasma nitriding].
Wen K; Li F
Zhonghua Kou Qiang Yi Xue Za Zhi; 2015 Dec; 50(12):751-4. PubMed ID: 26887401
[TBL] [Abstract][Full Text] [Related]
7. Influence of stress corrosion on the mechanical properties of laser-welded titanium.
de Assis Ferreira N; Senna PM; do Lago DC; de Senna LF; Sampaio-Filho HR
J Prosthet Dent; 2016 Mar; 115(3):356-62. PubMed ID: 26548870
[TBL] [Abstract][Full Text] [Related]
8. [Effect of TiN coating on corrosion resistance of dental NiCr alloy].
Hu B; Chen J
Shanghai Kou Qiang Yi Xue; 2009 Feb; 18(1):73-6. PubMed ID: 19290433
[TBL] [Abstract][Full Text] [Related]
9. Surface analysis and corrosion behavior of pure titanium under fluoride exposure.
Chen WQ; Zhang SM; Qiu J
J Prosthet Dent; 2020 Aug; 124(2):239.e1-239.e8. PubMed ID: 32402439
[TBL] [Abstract][Full Text] [Related]
10. Effect of Ag on the corrosion behavior of Ti-Ag alloys in artificial saliva solutions.
Zhang BB; Zheng YF; Liu Y
Dent Mater; 2009 May; 25(5):672-7. PubMed ID: 19150734
[TBL] [Abstract][Full Text] [Related]
11. Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution.
Duarte AR; Neto JP; Souza JC; Bonachela WC
J Prosthodont; 2013 Jun; 22(4):275-81. PubMed ID: 23107466
[TBL] [Abstract][Full Text] [Related]
12. How do titanium and Ti6Al4V corrode in fluoridated medium as found in the oral cavity? An in vitro study.
Souza JC; Barbosa SL; Ariza EA; Henriques M; Teughels W; Ponthiaux P; Celis JP; Rocha LA
Mater Sci Eng C Mater Biol Appl; 2015 Feb; 47():384-93. PubMed ID: 25492211
[TBL] [Abstract][Full Text] [Related]
13. [The effect of fluoride on electrochemical corrosion of the dental pure titanium before and after adhesion of Streptococcus mutans].
Geng L; Qiao GY; Gu KK
Shanghai Kou Qiang Yi Xue; 2016 Apr; 25(2):150-6. PubMed ID: 27329875
[TBL] [Abstract][Full Text] [Related]
14. Corrosion and Wear Behavior of TiO
Bakhtiari-Zamani H; Saebnoori E; Bakhsheshi-Rad HR; Berto F
Materials (Basel); 2022 Nov; 15(23):. PubMed ID: 36499797
[TBL] [Abstract][Full Text] [Related]
15. Comparison of friction force between corroded and noncorroded titanium nitride plating of metal brackets.
Kao CT; Guo JU; Huang TH
Am J Orthod Dentofacial Orthop; 2011 May; 139(5):594-600. PubMed ID: 21536201
[TBL] [Abstract][Full Text] [Related]
16. Stability of plasma electrolytic oxidation coating on titanium in artificial saliva.
Matykina E; Arrabal R; Mohedano M; Pardo A; Merino MC; Rivero E
J Mater Sci Mater Med; 2013 Jan; 24(1):37-51. PubMed ID: 23073838
[TBL] [Abstract][Full Text] [Related]
17. Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride.
Takemoto S; Hattori M; Yoshinari M; Kawada E; Asami K; Oda Y
Dent Mater J; 2004 Sep; 23(3):379-86. PubMed ID: 15510869
[TBL] [Abstract][Full Text] [Related]
18. Surface properties of Ti-35Nb-7Zr-5Ta: Effects of long-term immersion in artificial saliva and fluoride solution.
Miotto LN; Fais LM; Ribeiro AL; Vaz LG
J Prosthet Dent; 2016 Jul; 116(1):102-11. PubMed ID: 26831918
[TBL] [Abstract][Full Text] [Related]
19. Surface treatment influences electrochemical stability of cpTi exposed to mouthwashes.
Beline T; Garcia CS; Ogawa ES; Marques ISV; Matos AO; Sukotjo C; Mathew MT; Mesquita MF; Consani RX; Barão VAR
Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():1079-1088. PubMed ID: 26652467
[TBL] [Abstract][Full Text] [Related]
20. Hybrid diffusive/PVD treatments to improve the tribological resistance of Ti-6Al-4V.
Marin E; Offoiach R; Lanzutti A; Regis M; Fusi S; Fedrizzi L
Biomed Mater Eng; 2014; 24(1):581-92. PubMed ID: 24211942
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]