These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 27062442)

  • 1. Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions.
    Al-Hajjar M; Carbone S; Jennings LM; Begand S; Oberbach T; Delfosse D; Fisher J
    J Biomed Mater Res B Appl Biomater; 2017 Aug; 105(6):1361-1368. PubMed ID: 27062442
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wear of novel ceramic-on-ceramic bearings under adverse and clinically relevant hip simulator conditions.
    Al-Hajjar M; Jennings LM; Begand S; Oberbach T; Delfosse D; Fisher J
    J Biomed Mater Res B Appl Biomater; 2013 Nov; 101(8):1456-62. PubMed ID: 23744622
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combined wear and ageing of ceramic-on-ceramic bearings in total hip replacement under edge loading conditions.
    Al-Hajjar M; Gremillard L; Begand S; Oberbach T; Hans K; Delfosse D; Chevalier J; Jennings LM
    J Mech Behav Biomed Mater; 2019 Oct; 98():40-47. PubMed ID: 31185443
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.
    Al-Hajjar M; Fisher J; Tipper JL; Williams S; Jennings LM
    Proc Inst Mech Eng H; 2013 May; 227(5):535-42. PubMed ID: 23637263
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations.
    Halma JJ; Señaris J; Delfosse D; Lerf R; Oberbach T; van Gaalen SM; de Gast A
    J Biomed Mater Res B Appl Biomater; 2014 Nov; 102(8):1627-38. PubMed ID: 24652696
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A simple surrogate test method to rank the wear performance of prospective ceramic materials under hip prosthesis edge-loading conditions.
    Sanders AP; Brannon RM
    J Biomed Mater Res B Appl Biomater; 2014 Feb; 102(2):311-21. PubMed ID: 23996812
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.
    O'Dwyer Lancaster-Jones O; Williams S; Jennings LM; Thompson J; Isaac GH; Fisher J; Al-Hajjar M
    J Biomed Mater Res B Appl Biomater; 2018 Jul; 106(5):1897-1906. PubMed ID: 28941162
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement.
    Al-Hajjar M; Leslie IJ; Tipper J; Williams S; Fisher J; Jennings LM
    J Biomed Mater Res B Appl Biomater; 2010 Nov; 95(2):263-8. PubMed ID: 20860044
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions.
    Williams SR; Wu JJ; Unsworth A; Khan I
    Proc Inst Mech Eng H; 2011 Aug; 225(8):783-96. PubMed ID: 21922955
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reducing fretting-initiated crevice corrosion in hip simulator tests using a zirconia-toughened alumina femoral head.
    Kyomoto M; Shoyama Y; Saiga K; Moro T; Ishihara K
    J Biomed Mater Res B Appl Biomater; 2018 Nov; 106(8):2815-2826. PubMed ID: 29266687
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
    Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
    Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ceramic prosthesis surfaces induce an inflammatory cell response and fibrotic tissue changes.
    Bertrand J; Delfosse D; Mai V; Awiszus F; Harnisch K; Lohmann CH
    Bone Joint J; 2018 Jul; 100-B(7):882-890. PubMed ID: 29954216
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chemistry-driven structural alterations in short-term retrieved ceramic-on-metal hip implants: Evidence for in vivo incompatibility between ceramic and metal counterparts.
    Zhu W; Pezzotti G; Boffelli M; Chotanaphuti T; Khuangsirikul S; Sugano N
    J Biomed Mater Res B Appl Biomater; 2017 Aug; 105(6):1469-1480. PubMed ID: 27087384
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microseparation and stripe wear in alumina-on-alumina hip implants.
    Affatato S; Traina F; Toni A
    Int J Artif Organs; 2011 Jun; 34(6):506-12. PubMed ID: 21725932
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a new methodology to simulate damage and wear of polyethylene hip replacements subjected to edge loading in hip simulator testing.
    Partridge S; Tipper JL; Al-Hajjar M; Isaac GH; Fisher J; Williams S
    J Biomed Mater Res B Appl Biomater; 2018 May; 106(4):1456-1462. PubMed ID: 28661563
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wear of surface-engineered metal-on-metal bearings for hip prostheses under adverse conditions with the head loading on the rim of the cup.
    Leslie I; Williams S; Isaac G; Hatto P; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2013 Apr; 227(4):345-9. PubMed ID: 23637209
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pushing Ceramic-on-Ceramic in the most extreme wear conditions: A hip simulator study.
    De Fine M; Terrando S; Hintner M; Porporati AA; Pignatti G
    Orthop Traumatol Surg Res; 2021 Feb; 107(1):102643. PubMed ID: 32684432
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads.
    Yamane S; Kyomoto M; Moro T; Hashimoto M; Takatori Y; Tanaka S; Ishihara K
    J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1028-1037. PubMed ID: 28485068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of ceramic-on-metal and metal-on-metal hip prostheses under adverse conditions.
    Williams S; Al-Hajjar M; Isaac GH; Fisher J
    J Biomed Mater Res B Appl Biomater; 2013 Jul; 101(5):770-5. PubMed ID: 23359608
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.