These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 27063121)

  • 21. Retentive forces and fatigue resistance of thermoplastic resin clasps.
    Tannous F; Steiner M; Shahin R; Kern M
    Dent Mater; 2012 Mar; 28(3):273-8. PubMed ID: 22130464
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [A three-dimensional finite element analysis on relationship between abutment undercut and retentive arm width of cast cobalt-chromium three-arm clasp].
    Wang SY; Zhang ZT; Bai BJ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 May; 42(5):276-9. PubMed ID: 17686278
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Change in the retentive force of Akers clasp for zirconia crown by repetitive insertion and removal test.
    Tanaka A; Miyake N; Hotta H; Takemoto S; Yoshinari M; Yamashita S
    J Prosthodont Res; 2019 Oct; 63(4):447-452. PubMed ID: 30904359
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fitness accuracy and retentive forces of additive manufactured titanium clasp.
    Takahashi K; Torii M; Nakata T; Kawamura N; Shimpo H; Ohkubo C
    J Prosthodont Res; 2020 Oct; 64(4):468-477. PubMed ID: 32063534
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effects of clasp retention forces and abrasion on different cast crowns.
    Jiang N; Gao WM; Zhang H; Zheng DX
    J Prosthet Dent; 2014 Jun; 111(6):493-8. PubMed ID: 24423460
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The flexibility of titanium clasps compared with cobalt-chromium clasps.
    Essop AR; Salt SA; Sykes LM; Chandler HD; Becker PJ
    SADJ; 2000 Dec; 55(12):672-7. PubMed ID: 12608241
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Fatigue resistance and retentive force of cast clasps treated by shot peening.
    Tokue A; Hayakawa T; Ohkubo C
    J Prosthodont Res; 2013 Jul; 57(3):186-94. PubMed ID: 23809297
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Analysis of retention of 3 different aesthetic Co-Cr-Mo alloy clasps on premolars].
    Wu XY; Zhong Q
    Shanghai Kou Qiang Yi Xue; 2016 Jun; 25(3):284-7. PubMed ID: 27609378
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Retentive Forces of Removable Partial Denture Clasp Assemblies Made from Polyaryletherketone and Cobalt-Chromium: A Comparative Study.
    Gentz FI; Brooks DI; Liacouras PC; Petrich A; Hamlin CM; Ellert DO; Ye L
    J Prosthodont; 2022 Apr; 31(4):299-304. PubMed ID: 34081360
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effects of 3 kinds of processing techniques on the fitness of metal clasp.
    Yin X; Zhou H; Yan F; Wu X; Wu G; Pang D
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 46(10):1122-1128. PubMed ID: 34911843
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Retention force of T-bar clasps for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Macedo AP; de Torres EM; de Mattos Mda G; Ribeiro RF
    Braz Dent J; 2008; 19(3):209-13. PubMed ID: 18949292
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fitness accuracy and retentive forces of milled titanium clasp.
    Maruo R; Shimpo H; Kimoto K; Hayakawa T; Miura H; Ohkubo C
    Dent Mater J; 2022 May; 41(3):414-420. PubMed ID: 35135942
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Study on elastic limit and relevant enclasp force of non-precious metal casting clasp].
    Cheng H; Zheng M; Wu WQ; Huang ZY; Li XR; Cheng XR
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2004 May; 39(3):227-9. PubMed ID: 15196393
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study.
    Tan FB; Song JL; Wang C; Fan YB; Dai HW
    J Prosthodont Res; 2019 Jan; 63(1):58-65. PubMed ID: 30309743
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.
    Sćepanović M; Tihacek-Sojić L; Tasić M; Mitrović R; Todorović A; Trifković B
    Vojnosanit Pregl; 2013 Nov; 70(11):999-1005. PubMed ID: 24397193
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A comparison of various removable partial denture clasp materials and fabrication procedure for placing clasps on canine and premolar teeth.
    VandenBrink JP; Wolfaardt JF; Faulkner MG
    J Prosthet Dent; 1993 Aug; 70(2):180-8. PubMed ID: 8103801
    [TBL] [Abstract][Full Text] [Related]  

  • 37. In vitro Assessment of Clasps of Cobalt-Chromium and Nickel-titanium Alloys in Removable Prosthesis.
    Kola MZ; Raghav D; Kumar P; Alqahtani F; Murayshed MS; Bhagat TV
    J Contemp Dent Pract; 2016 Mar; 17(3):253-7. PubMed ID: 27207207
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Duration of induction melting of cobalt-chromium alloy and its effect on resistance to deflection fatigue of cast denture clasps.
    Vallittu PK; Miettinen T
    J Prosthet Dent; 1996 Mar; 75(3):332-6. PubMed ID: 8648583
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Flexibility of technopolymer clasps compared with cobalt-chromium and titanium clasps.
    Sykes LM; Dullabh HD; Chandler HD; Bunn B; Essop AR
    SADJ; 2002 May; 57(5):166-71. PubMed ID: 12174711
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparative study of two commercially pure titanium casting methods.
    Rodrigues RC; Faria AC; Orsi IA; Mattos Mda G; Macedo AP; Ribeiro RF
    J Appl Oral Sci; 2010; 18(5):487-92. PubMed ID: 21085805
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.