These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 27070604)

  • 21. A hierarchically patterned, bioinspired e-skin able to detect the direction of applied pressure for robotics.
    Boutry CM; Negre M; Jorda M; Vardoulis O; Chortos A; Khatib O; Bao Z
    Sci Robot; 2018 Nov; 3(24):. PubMed ID: 33141713
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Magnetic sensor for configurable measurement of tension or elasticity with validation in animal soft tissues.
    Singal K; Rajamani R; Ahmadi M; Serdar Sezen A; Bechtold JE
    IEEE Trans Biomed Eng; 2015 Feb; 62(2):426-37. PubMed ID: 25222945
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Characterization of a silicon-based shear-force sensor on human subjects.
    Wang L; Beebe DJ
    IEEE Trans Biomed Eng; 2002 Nov; 49(11):1340-7. PubMed ID: 12450364
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An Integrated Compensation Method for the Force Disturbance of a Six-Axis Force Sensor in Complex Manufacturing Scenarios.
    Yao L; Gao Q; Zhang D; Zhang W; Chen Y
    Sensors (Basel); 2021 Jul; 21(14):. PubMed ID: 34300443
    [TBL] [Abstract][Full Text] [Related]  

  • 25. All-Digital Time-Domain CMOS Smart Temperature Sensor with On-Chip Linearity Enhancement.
    Chen CC; Chen CL; Lin Y
    Sensors (Basel); 2016 Jan; 16(2):176. PubMed ID: 26840316
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Robot-assisted Sistrunk's operation, total thyroidectomy, and neck dissection via a transaxillary and retroauricular (TARA) approach in papillary carcinoma arising in thyroglossal duct cyst and thyroid gland.
    Byeon HK; Ban MJ; Lee JM; Ha JG; Kim ES; Koh YW; Choi EC
    Ann Surg Oncol; 2012 Dec; 19(13):4259-61. PubMed ID: 23070784
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of neonatal skin sensor temperatures with axillary temperature: does skin sensor placement really matter?
    Schafer D; Boogaart S; Johnson L; Keezel C; Ruperts L; Vander Laan KJ
    Adv Neonatal Care; 2014 Feb; 14(1):52-60. PubMed ID: 24472889
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A new approach to detect mover position in linear motors using magnetic sensors.
    Paul S; Chang J
    Sensors (Basel); 2015 Oct; 15(10):26694-708. PubMed ID: 26506348
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Integration of a miniaturised triaxial force sensor in a minimally invasive surgical tool.
    Valdastri P; Harada K; Menciassi A; Beccai L; Stefanini C; Fujie M; Dario P
    IEEE Trans Biomed Eng; 2006 Nov; 53(11):2397-400. PubMed ID: 17073346
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A self-powered AC magnetic sensor based on piezoelectric nanogenerator.
    Yu A; Song M; Zhang Y; Kou J; Zhai J; Lin Wang Z
    Nanotechnology; 2014 Nov; 25(45):455503. PubMed ID: 25333328
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Role of friction and tangential force variation in the subjective scaling of tactile roughness.
    Smith AM; Chapman CE; Deslandes M; Langlais JS; Thibodeau MP
    Exp Brain Res; 2002 May; 144(2):211-23. PubMed ID: 12012159
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Application of High-Photoelasticity Polyurethane to Tactile Sensor for Robot Hands.
    Mitsuzuka M; Takarada J; Kawahara I; Morimoto R; Wang Z; Kawamura S; Tajitsu Y
    Polymers (Basel); 2022 Nov; 14(23):. PubMed ID: 36501451
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A piezoresistive tactile sensor for tissue characterization during catheter-based cardiac surgery.
    Kalantari M; Ramezanifard M; Ahmadi R; Dargahi J; Kövecses J
    Int J Med Robot; 2011 Dec; 7(4):431-40. PubMed ID: 21976393
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Friction force measurement during cochlear implant insertion: application to a force-controlled insertion tool design.
    Miroir M; Nguyen Y; Kazmitcheff G; Ferrary E; Sterkers O; Grayeli AB
    Otol Neurotol; 2012 Aug; 33(6):1092-100. PubMed ID: 22772019
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An inductive sensor for real-time measurement of plantar normal and shear forces distribution.
    Du L; Zhu X; Zhe J
    IEEE Trans Biomed Eng; 2015 May; 62(5):1316-23. PubMed ID: 25546856
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A New Design of a Single-Device 3D Hall Sensor: Cross-Shaped 3D Hall Sensor.
    Tang W; Lyu F; Wang D; Pan H
    Sensors (Basel); 2018 Apr; 18(4):. PubMed ID: 29614815
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Design of a dual sensor probe array for internal field measurement in Versatile Experiment Spherical Torus.
    Jeong-hun Y; Chung KJ; An Y; Jung BK; Jo JG; Hwang YS
    Rev Sci Instrum; 2012 Oct; 83(10):10D721. PubMed ID: 23126895
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Design and Analysis of a Sensor System for Cutting Force Measurement in Machining Processes.
    Liang Q; Zhang D; Coppola G; Mao J; Sun W; Wang Y; Ge Y
    Sensors (Basel); 2016 Jan; 16(1):. PubMed ID: 26751451
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A miniature tension sensor to measure surgical suture tension of deformable musculoskeletal tissues during joint motion.
    Kiriyama Y; Matsumoto H; Toyama Y; Nagura T
    Proc Inst Mech Eng H; 2014 Feb; 228(2):140-8. PubMed ID: 24436492
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of a sensor for low interface pressure applications.
    Ferguson-Pell M; Hagisawa S; Bain D
    Med Eng Phys; 2000 Nov; 22(9):657-63. PubMed ID: 11259934
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.