These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 27072091)

  • 1. Effect of peripheral nerve tetanic stimulation on the inter-trial variability and accuracy of transcranial motor-evoked potential in brain surgery.
    Kim JS; Choi Y; Jin SH; Kim CH; Park CK; Kim SM; Lee KW; Chung CK; Paek SH
    Clin Neurophysiol; 2016 May; 127(5):2208-13. PubMed ID: 27072091
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of reliability of post-tetanic motor-evoked potential monitoring during spinal surgery under general anesthesia.
    Hayashi H; Kawaguchi M; Yamamoto Y; Inoue S; Koizumi M; Ueda Y; Takakura Y; Furuya H
    Spine (Phila Pa 1976); 2008 Dec; 33(26):E994-E1000. PubMed ID: 19092611
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The application of tetanic stimulation of the unilateral tibial nerve before transcranial stimulation can augment the amplitudes of myogenic motor-evoked potentials from the muscles in the bilateral upper and lower limbs.
    Hayashi H; Kawaguchi M; Yamamoto Y; Inoue S; Koizumi M; Ueda Y; Takakura Y; Furuya H
    Anesth Analg; 2008 Jul; 107(1):215-20. PubMed ID: 18635490
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tetanic stimulation of the pudendal nerve prior to transcranial electrical stimulation augments the amplitude of motor evoked potentials during pediatric neurosurgery.
    Takatani T; Motoyama Y; Park YS; Kim T; Hayashi H; Nakagawa I; Kawaguchi M; Nakase H
    J Neurosurg Pediatr; 2021 Apr; 27(6):707-715. PubMed ID: 33892470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of posttetanic motor evoked potentials--the influences of repetitive use, the residual effects of tetanic stimulation to peripheral nerve, and the variability.
    Yamamoto Y; Kawaguchi M; Hayashi H; Abe R; Inoue S; Nakase H; Sakaki T; Furuya H
    J Neurosurg Anesthesiol; 2010 Jan; 22(1):6-10. PubMed ID: 19779367
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of intraoperative motor evoked potential amplification following tetanic stimulation of the pudendal nerve in pediatric craniotomy.
    Sasaki R; Tamura K; Yamazaki S; Kim TK; Takatani T; Hayashi H; Motoyama Y; Nakagawa I; Park YS; Kawaguchi M; Nakase H
    J Neurosurg Pediatr; 2023 May; 31(5):488-495. PubMed ID: 36840735
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of the neuromuscular blockade levels on amplitudes of posttetanic motor-evoked potentials and movement in response to transcranial stimulation in patients receiving propofol and fentanyl anesthesia.
    Yamamoto Y; Kawaguchi M; Hayashi H; Horiuchi T; Inoue S; Nakase H; Sakaki T; Furuya H
    Anesth Analg; 2008 Mar; 106(3):930-4, table of contents. PubMed ID: 18292442
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Facilitation of motor evoked potentials after tetanic peripheral nerve stimulation.
    Wehab Z; Lutz MW; Bell EP; Johnson HE; AlGaeed M; Husain AM
    Clin Neurophysiol; 2024 Jun; 162():2-8. PubMed ID: 38547586
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Post-tetanic transcranial motor evoked potentials augment the amplitude of compound muscle action potentials recorded from innervated and non-innervated muscles.
    Shigematsu H; Kawaguchi M; Hayashi H; Takatani T; Iwata E; Tanaka M; Okuda A; Morimoto Y; Masuda K; Yamamoto Y; Tanaka Y
    Spine J; 2018 May; 18(5):740-746. PubMed ID: 28870837
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the Wake-up Test and Combined TES-MEP and CSEP Monitoring in Spinal Surgery.
    Chen B; Chen Y; Yang J; Xie D; Su H; Li F; Wan Y; Peng X; Zheng Z
    J Spinal Disord Tech; 2015 Nov; 28(9):335-40. PubMed ID: 24141342
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Significance of intraoperative motor function monitoring using transcranial electrical motor evoked potentials (MEP) in patients with spinal and cranial lesions near the motor pathways.
    Krammer MJ; Wolf S; Schul DB; Gerstner W; Lumenta CB
    Br J Neurosurg; 2009 Feb; 23(1):48-55. PubMed ID: 19234909
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tetanic stimulation of the peripheral nerve augments motor evoked potentials by re-exciting spinal anterior horn cells.
    Yamamoto Y; Shigematsu H; Kawaguchi M; Hayashi H; Takatani T; Tanaka M; Okuda A; Kawasaki S; Masuda K; Suga Y; Tanaka Y
    J Clin Monit Comput; 2022 Feb; 36(1):259-270. PubMed ID: 33420971
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the applicability of sevoflurane during post-tetanic myogenic motor evoked potential monitoring in patients undergoing spinal surgery.
    Hayashi H; Kawaguchi M; Abe R; Yamamoto Y; Inoue S; Koizumi M; Takakura Y; Furuya H
    J Anesth; 2009; 23(2):175-81. PubMed ID: 19444553
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraoperative multimodal evoked potential monitoring during carotid endarterectomy: a retrospective study of 264 patients.
    Malcharek MJ; Kulpok A; Deletis V; Ulkatan S; Sablotzki A; Hennig G; Gille J; Pilge S; Schneider G
    Anesth Analg; 2015 Jun; 120(6):1352-60. PubMed ID: 24977915
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel threshold criterion in transcranial motor evoked potentials during surgery for gliomas close to the motor pathway.
    Abboud T; Schaper M; Dührsen L; Schwarz C; Schmidt NO; Westphal M; Martens T
    J Neurosurg; 2016 Oct; 125(4):795-802. PubMed ID: 26799297
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Warning thresholds on the basis of origin of amplitude changes in transcranial electrical motor-evoked potential monitoring for cervical compression myelopathy.
    Sakaki K; Kawabata S; Ukegawa D; Hirai T; Ishii S; Tomori M; Inose H; Yoshii T; Tomizawa S; Kato T; Shinomiya K; Okawa A
    Spine (Phila Pa 1976); 2012 Jul; 37(15):E913-21. PubMed ID: 22322375
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Strategies and Pitfalls of Motor-Evoked Potential Monitoring during Supratentorial Aneurysm Surgery.
    Maruta Y; Fujii M; Imoto H; Nomura S; Tanaka N; Inamura A; Sadahiro H; Oka F; Goto H; Shirao S; Ideguchi M; Yoneda H; Suehiro E; Koizumi H; Ishihara H; Suzuki M
    J Stroke Cerebrovasc Dis; 2016 Feb; 25(2):484-95. PubMed ID: 26639401
    [TBL] [Abstract][Full Text] [Related]  

  • 18. "Threshold-level" multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring.
    Calancie B; Harris W; Broton JG; Alexeeva N; Green BA
    J Neurosurg; 1998 Mar; 88(3):457-70. PubMed ID: 9488299
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of motor-evoked potentials monitoring in response to transcranial electrical stimulation in subjects undergoing neurosurgery with partial vs no neuromuscular block.
    Kim WH; Lee JJ; Lee SM; Park MN; Park SK; Seo DW; Chung IS
    Br J Anaesth; 2013 Apr; 110(4):567-76. PubMed ID: 23378247
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of desflurane as an anesthetic in motor-evoked potentials in spine surgery and the facilitating effect in tetanic stimulation of bilateral median nerves.
    Kawasaki S; Shigematsu H; Tanaka M; Kawaguchi M; Hayashi H; Takatani T; Suga Y; Yamamoto Y; Tanaka Y
    J Clin Monit Comput; 2024 Jun; 38(3):663-670. PubMed ID: 37917209
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.