These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
395 related articles for article (PubMed ID: 27078175)
1. Numerical and Experimental Analyses on the Temperature Distribution in the Dental Implant Preparation Area when Using a Surgical Guide. Liu YF; Wu JL; Zhang JX; Peng W; Liao WQ J Prosthodont; 2018 Jan; 27(1):42-51. PubMed ID: 27078175 [TBL] [Abstract][Full Text] [Related]
2. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs. Marković A; Lazić Z; Mišić T; Šćepanović M; Todorović A; Thakare K; Janjić B; Vlahović Z; Glišić M Vojnosanit Pregl; 2016 Aug; 73(8):744-50. PubMed ID: 29328609 [TBL] [Abstract][Full Text] [Related]
3. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants. Bulloch SE; Olsen RG; Bulloch B Int J Oral Maxillofac Implants; 2012; 27(6):1456-60. PubMed ID: 23189297 [TBL] [Abstract][Full Text] [Related]
4. Effect of the Combination of Low-Speed Drilling and Cooled Irrigation Fluid on Intraosseous Heat Generation During Guided Surgical Implant Site Preparation: An In Vitro Study. Barrak I; Joób-Fancsaly A; Varga E; Boa K; Piffko J Implant Dent; 2017 Aug; 26(4):541-546. PubMed ID: 28542041 [TBL] [Abstract][Full Text] [Related]
5. Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review. Bernabeu-Mira JC; Soto-Peñaloza D; Peñarrocha-Diago M; Camacho-Alonso F; Rivas-Ballester R; Peñarrocha-Oltra D Clin Oral Investig; 2021 Jul; 25(7):4251-4267. PubMed ID: 33893557 [TBL] [Abstract][Full Text] [Related]
6. The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an ex vivo study. Gehrke SA; Aramburú Júnior JS; Pérez-Albacete Martínez C; Ramirez Fernandez MP; Maté Sánchez de Val JE; Calvo-Guirado JL Clin Oral Implants Res; 2018 Jul; 29(7):772-778. PubMed ID: 27041138 [TBL] [Abstract][Full Text] [Related]
7. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model. Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104 [TBL] [Abstract][Full Text] [Related]
8. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills. Scarano A; Piattelli A; Assenza B; Carinci F; Di Donato L; Romani GL; Merla A Clin Implant Dent Relat Res; 2011 Dec; 13(4):319-23. PubMed ID: 19681941 [TBL] [Abstract][Full Text] [Related]
9. Effect of different dental implant drilling template designs on heat generation during osteotomy - an in vitro study. Waltenberger L; Wied S; Wolfart S; Tuna T Clin Oral Implants Res; 2022 Jan; 33(1):53-64. PubMed ID: 34587303 [TBL] [Abstract][Full Text] [Related]
10. Effect of surgical drill guide on heat generated from implant drilling. Misir AF; Sumer M; Yenisey M; Ergioglu E J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988 [TBL] [Abstract][Full Text] [Related]
12. Temperature change in pig rib bone during implant site preparation by low-speed drilling. Kim SJ; Yoo J; Kim YS; Shin SW J Appl Oral Sci; 2010; 18(5):522-7. PubMed ID: 21085811 [TBL] [Abstract][Full Text] [Related]
13. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model. Strbac GD; Unger E; Donner R; Bijak M; Watzek G; Zechner W Clin Oral Implants Res; 2014 Jun; 25(6):665-74. PubMed ID: 23009204 [TBL] [Abstract][Full Text] [Related]
14. Thermal Changes During Guided Flapless Implant Site Preparation: A Comparative Study. Sannino G; Gherlone EF Int J Oral Maxillofac Implants; 2018; 33(3):671-677. PubMed ID: 29763502 [TBL] [Abstract][Full Text] [Related]
15. Intra-osseous heat generation during implant bed preparation with static navigation: Multi-factor in vitro study. Gargallo-Albiol J; Salomó-Coll O; Lozano-Carrascal N; Wang HL; Hernández-Alfaro F Clin Oral Implants Res; 2021 May; 32(5):590-597. PubMed ID: 33629419 [TBL] [Abstract][Full Text] [Related]
16. Intraosseous Temperature Changes During Implant Site Preparation: In Vitro Comparison of Thermocouples and Infrared Thermography. Harder S; Egert C; Freitag-Wolf S; Mehl C; Kern M Int J Oral Maxillofac Implants; 2018; 33(1):72-78. PubMed ID: 29340345 [TBL] [Abstract][Full Text] [Related]
17. Addition of an irrigation channel to a surgical template to facilitate cooling during implant osteotomy. Orgev A; Gonzaga L; Martin W; Morton D; Lin WS J Prosthet Dent; 2021 Aug; 126(2):164-166. PubMed ID: 32800579 [TBL] [Abstract][Full Text] [Related]
18. 3D printed implant surgical guides with internally routed irrigation for temperature reduction during osteotomy preparation: A pilot study. Teich S; Bocklet M; Evans Z; Gutmacher Z; Renne W J Esthet Restor Dent; 2022 Jul; 34(5):796-803. PubMed ID: 34837657 [TBL] [Abstract][Full Text] [Related]
19. Multistepped Drill Design for Single-Stage Implant Site Preparation: Experimental Study in Type 2 Bone. Abboud M; Delgado-Ruiz RA; Kucine A; Rugova S; Balanta J; Calvo-Guirado JL Clin Implant Dent Relat Res; 2015 Oct; 17 Suppl 2():e472-85. PubMed ID: 25263993 [TBL] [Abstract][Full Text] [Related]
20. Novel hybrid drilling protocol: evaluation for the implant healing--thermal changes, crestal bone loss, and bone-to-implant contact. Calvo-Guirado JL; Delgado-Peña J; Maté-Sánchez JE; Mareque Bueno J; Delgado-Ruiz RA; Romanos GE Clin Oral Implants Res; 2015 Jul; 26(7):753-60. PubMed ID: 24502654 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]