102 related articles for article (PubMed ID: 2708001)
1. Prevention of postoperative wound dehiscence in high risk patients. A randomized comparison of internally applied resorbable polyglactin 910 mesh and externally applied polyamide fiber mesh.
Gainant A; Boudinet F; Cubertafond P
Int Surg; 1989; 74(1):55-7. PubMed ID: 2708001
[TBL] [Abstract][Full Text] [Related]
2. [Intraperitoneal resorbable mesh in the prevention of postoperative wound dehiscence. A comparative study].
Paye F; Rongère C; Gendreau D; Lenriot JP
Ann Chir; 1992; 46(6):518-22. PubMed ID: 1444152
[TBL] [Abstract][Full Text] [Related]
3. [Prevention of postoperative wound dehiscence. Comparative study of polyglactin 910 mesh and total reinforced extraperitoneal sutures].
Tohme C; Brechet E; Bernard A; Arnaud R; Viard H
Ann Chir; 1991; 45(6):513-6. PubMed ID: 1929168
[TBL] [Abstract][Full Text] [Related]
4. Use of an absorbable polyglactin mesh for the prevention of incisional hernias.
Pans A; Desaive C
Acta Chir Belg; 1995; 95(6):265-8. PubMed ID: 8571717
[TBL] [Abstract][Full Text] [Related]
5. Prevention of sternal dehiscence and infection in high-risk patients: a prospective randomized multicenter trial.
Schimmer C; Reents W; Berneder S; Eigel P; Sezer O; Scheld H; Sahraoui K; Gansera B; Deppert O; Rubio A; Feyrer R; Sauer C; Elert O; Leyh R
Ann Thorac Surg; 2008 Dec; 86(6):1897-904. PubMed ID: 19022005
[TBL] [Abstract][Full Text] [Related]
6. Burst abdomen and incisional hernia after major gastrointestinal operations--comparison of three closure techniques.
Gislason H; Grønbech JE; Søreide O
Eur J Surg; 1995 May; 161(5):349-54. PubMed ID: 7662780
[TBL] [Abstract][Full Text] [Related]
7. Absorbable mesh and topical negative pressure therapy for closure of abdominal dehiscence with exposed bowel.
Chuo CB; Thomas SS
J Plast Reconstr Aesthet Surg; 2008 Nov; 61(11):1378-81. PubMed ID: 17544349
[TBL] [Abstract][Full Text] [Related]
8. Experimental evaluation of a new composite mesh with the selective property of incorporation to the abdominal wall without adhering to the intestines.
Amid PK; Shulman AG; Lichtenstein IL; Sostrin S; Young J; Hakakha M
J Biomed Mater Res; 1994 Mar; 28(3):373-5. PubMed ID: 8077252
[TBL] [Abstract][Full Text] [Related]
9. [Results of a controlled trial comparing 3 suture threads at slow resorption for the closure of supra-umbilical midline laparotomies].
Bresler L; Courbey PJ; Feldman L; Bilweiss J; Tortuyaux JM; Rauch P; Boissel P; Grosdidier J
Ann Chir; 1995; 49(6):544-8. PubMed ID: 8526449
[TBL] [Abstract][Full Text] [Related]
10. Wound complications after closure of abdominal incisions with Dexon or Vicryl. A randomized double-blind study.
Gammelgaard N; Jensen J
Acta Chir Scand; 1983; 149(5):505-8. PubMed ID: 6314720
[TBL] [Abstract][Full Text] [Related]
11. Primary sternal plating in high-risk patients prevents mediastinitis.
Song DH; Lohman RF; Renucci JD; Jeevanandam V; Raman J
Eur J Cardiothorac Surg; 2004 Aug; 26(2):367-72. PubMed ID: 15296898
[TBL] [Abstract][Full Text] [Related]
12. Management of abdominal wound dehiscence using vacuum assisted closure in patients with compromised healing.
Heller L; Levin SL; Butler CE
Am J Surg; 2006 Feb; 191(2):165-72. PubMed ID: 16442940
[TBL] [Abstract][Full Text] [Related]
13. Technique and complications of reconstruction of the pelvic floor with polyglactin mesh.
Sener SF; Imperato JP; Blum MD; Ignatoff JM; Soper TG; Winchester DP; Meiselman M
Surg Gynecol Obstet; 1989 Jun; 168(6):475-80. PubMed ID: 2727876
[TBL] [Abstract][Full Text] [Related]
14. Factors affecting wound complications in repair of ventral hernias.
White TJ; Santos MC; Thompson JS
Am Surg; 1998 Mar; 64(3):276-80. PubMed ID: 9520825
[TBL] [Abstract][Full Text] [Related]
15. Frequency and risk factors for wound dehiscence/burst abdomen in midline laparotomies.
Waqar SH; Malik ZI; Razzaq A; Abdullah MT; Shaima A; Zahid MA
J Ayub Med Coll Abbottabad; 2005; 17(4):70-3. PubMed ID: 16599042
[TBL] [Abstract][Full Text] [Related]
16. [Factors affecting disruption of surgical abdominal incisions in early postoperative period].
Gürleyik G
Ulus Travma Derg; 2001 Apr; 7(2):96-9. PubMed ID: 11705045
[TBL] [Abstract][Full Text] [Related]
17. Incisional hernia after repair of wound dehiscence: incidence and risk factors.
van't RM; De Vos Van Steenwijk PJ; Bonjer HJ; Steyerberg EW; Jeekel J
Am Surg; 2004 Apr; 70(4):281-6. PubMed ID: 15098775
[TBL] [Abstract][Full Text] [Related]
18. [Management of large abdominal wall hernias with foreign implant materials (Gore-Tex patch)].
Trupka AW; Schweiberer L; Hallfeldt K; Waldner H
Zentralbl Chir; 1997; 122(10):879-84. PubMed ID: 9446450
[TBL] [Abstract][Full Text] [Related]
19. Frequency and risk factor of abdominal wound dehiscence.
Khan MN; Naqvi AH; Irshad K; Chaudhary AR
J Coll Physicians Surg Pak; 2004 Jun; 14(6):355-7. PubMed ID: 15233890
[TBL] [Abstract][Full Text] [Related]
20. [Artificial mesh as an aid in abdominal wall closure in postoperative peritonitis, postoperative abdominal wall dehiscence and reconstruction of the abdominal wall].
Gross E; Erhard J; Eigler FW
Zentralbl Chir; 1984; 109(19):1238-50. PubMed ID: 6516616
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]