These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
180 related articles for article (PubMed ID: 2708415)
1. In vitro platelet interactions with a heparin-polyvinyl alcohol hydrogel. Cholakis CH; Sefton MV J Biomed Mater Res; 1989 Apr; 23(4):399-415. PubMed ID: 2708415 [TBL] [Abstract][Full Text] [Related]
2. Effect of heparin-PVA hydrogel on platelets in a chronic canine arterio-venous shunt. Cholakis CH; Zingg W; Sefton MV J Biomed Mater Res; 1989 Apr; 23(4):417-41. PubMed ID: 2708416 [TBL] [Abstract][Full Text] [Related]
3. Platelet consumption by polyvinyl alcohol coated tubing in canines. Ip WF; Sefton MV J Biomed Mater Res; 1991 Jul; 25(7):875-87. PubMed ID: 1918104 [TBL] [Abstract][Full Text] [Related]
4. [Study on heparin-like materials--sulfonization and blood compatibility of PVA, PET and PEU]. Tang S; Zou H Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1999 Sep; 16(3):283-7. PubMed ID: 12552745 [TBL] [Abstract][Full Text] [Related]
5. Preparation and thrombogenicity of alkylated polyvinyl alcohol coated tubing. Strzinar I; Sefton MV J Biomed Mater Res; 1992 May; 26(5):577-92. PubMed ID: 1512280 [TBL] [Abstract][Full Text] [Related]
6. In vitro platelet interactions in whole human blood exposed to biomaterial surfaces: insights on blood compatibility. Haycox CL; Ratner BD J Biomed Mater Res; 1993 Sep; 27(9):1181-93. PubMed ID: 8126017 [TBL] [Abstract][Full Text] [Related]
7. Immobilization of poly(ethylene glycol) onto a poly(vinyl alcohol) hydrogel: 2. Evaluation of thrombogenicity. Llanos GR; Sefton MV J Biomed Mater Res; 1993 Nov; 27(11):1383-91. PubMed ID: 8263000 [TBL] [Abstract][Full Text] [Related]
8. Parallel flow arteriovenous shunt for the ex vivo evaluation of heparinized materials. Ip WF; Zingg W; Sefton MV J Biomed Mater Res; 1985 Feb; 19(2):161-78. PubMed ID: 4077878 [TBL] [Abstract][Full Text] [Related]
9. Characterization of transient platelet contacts on a polyvinyl alcohol hydrogel by video microscopy. Godo MN; Sefton MV Biomaterials; 1999 Jun; 20(12):1117-26. PubMed ID: 10382827 [TBL] [Abstract][Full Text] [Related]
10. Properties of a heparin-poly(vinyl alcohol) hydrogel coating. Goosen MF; Sefton MV J Biomed Mater Res; 1983 Mar; 17(2):359-73. PubMed ID: 6841373 [TBL] [Abstract][Full Text] [Related]
11. In vitro and in vivo evaluation of blood coagulation activation of polyvinyl alcohol hydrogel plus dextran-based vascular grafts. Alexandre N; Costa E; Coimbra S; Silva A; Lopes A; Rodrigues M; Santos M; Maurício AC; Santos JD; Luís AL J Biomed Mater Res A; 2015 Apr; 103(4):1366-79. PubMed ID: 25044790 [TBL] [Abstract][Full Text] [Related]
12. Glow discharge plasma treatment of polyethylene tubing with tetraglyme results in ultralow fibrinogen adsorption and greatly reduced platelet adhesion. Cao L; Sukavaneshvar S; Ratner BD; Horbett TA J Biomed Mater Res A; 2006 Dec; 79(4):788-803. PubMed ID: 16883583 [TBL] [Abstract][Full Text] [Related]
13. Blood compatibility of novel poly(gamma-glutamic acid)/polyvinyl alcohol hydrogels. Lin WC; Yu DG; Yang MC Colloids Surf B Biointerfaces; 2006 Jan; 47(1):43-9. PubMed ID: 16386882 [TBL] [Abstract][Full Text] [Related]
15. The effect of heparin vs. citrate on the interaction of platelets with vascular graft materials. Kottke-Marchant K; Anderson JM; Rabinovitch A; Huskey RA; Herzig R Thromb Haemost; 1985 Dec; 54(4):842-8. PubMed ID: 2935968 [TBL] [Abstract][Full Text] [Related]
16. Composite device for attachment of polyvinyl alcohol-hydrogel to underlying bone. Kobayashi M; Oka M Artif Organs; 2004 Aug; 28(8):734-8. PubMed ID: 15270955 [TBL] [Abstract][Full Text] [Related]
17. Does the liquid method of electret forming influence the adhesion of blood platelets? Lowkis B; Szymanowicz M Polim Med; 1995; 25(1-2):3-13. PubMed ID: 7479426 [TBL] [Abstract][Full Text] [Related]
18. Thrombin and albumin adsorption to PVA and heparin-PVA hydrogels. I. Single protein isotherms. Smith BA; Sefton MV J Biomed Mater Res; 1992 Jul; 26(7):947-58. PubMed ID: 1607375 [TBL] [Abstract][Full Text] [Related]
19. Platelet compatibility of an artificial surface modified with functionally active heparin. Mollnes TE; Videm V; Christiansen D; Bergseth G; Riesenfeld J; Hovig T Thromb Haemost; 1999 Sep; 82(3):1132-6. PubMed ID: 10494777 [TBL] [Abstract][Full Text] [Related]
20. In vitro and ex vivo platelet interactions with hydrophilic-hydrophobic poly(ethylene oxide)-polystyrene multiblock copolymers. Grainger DW; Nojiri C; Okano T; Kim SW J Biomed Mater Res; 1989 Sep; 23(9):979-1005. PubMed ID: 2777836 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]